Home /Valves /

No Leakage Air Operated Diaphragm Pump Shut - Off Valves CE Approved

No Leakage Air Operated Diaphragm Pump Shut - Off Valves CE Approved

Brand Name:SAMA
Certification:CE
Model Number:50AL-P99
Minimum Order Quantity:10 Unit(s)
Delivery Time:15days
Payment Terms:FOB T/T
Contact Now

Add to Cart

Verified Supplier
Location: Foshan Guangdong China
Address: E 18Floor Fazhan Build No.13 Easy Huayuan Road Chancheng Area Foshan City.
Supplier`s last login times: within 38 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Aluminium Alloy Industrial Diaphragm Pump Shut - Off Valves No Leakage

Air Operated Diaphragm Pump General Description

diaphragm pump offers high volume delivery even at low air pressure and a b road range of material compatibility options available.Refer to the model and option chart.The BSK pump is provided with the modularized air motor and fluid section.
The air operated diaphragm pump alternately generates the intake fluid pressure and positive fluid pressure in the fluid chamber by using the pressure difference in the air chamber. The ball valve can ensure the forward flow of fluid.
Pump cycling will begin as air pressure is applied and it will continue to pump and keep up with the demand. It will build and maintain line pres -sure and will stop cycling once maximum line pressure is reached (dis -pensing device closed) and will resume pumping as needed.

Air diaphragm pump(also know as a Membrane pump, air operated double diaphragm pump(AOOD) or pneumatic diaphragm pump)that uses a combination of the reciprocating action of a rubber,thermoplastic or diaphragm and suitable valves either side of the diaphragm (check valve,butterfly valves,flap valves,or any other form of shut-off valves) to pump a fluid.

Air Operated Diaphragm Pump Description:


Air Inlet

1/4-18NPTF-1

Fluid Outlet

1-11-1/2NPTF-1,Rp1-11BSP

Fluid Inlet

1-11-1/2NPTF-1,Rp1-11BSP

Max. Flow

135L/Min

Max. Head

70M

Max. Self-priming Lift (dry)

4m

Max. Air Pressure

8.3bar

Max. Particle Diameter

3mm

Max. Installation Dimension

249.5×360.5×245mm

Weight

9.5kg

Noise

<80db


AODD Pumps can deal with all kinds of corrosive, volatile, flammable, poisonous fluids with particles and high viscosity.

1.The pump can suck the peanut, pickles, tomato slurry, red sausage, chocolate, hops and syrup etc.
2. The pump can suck the paint, pigment, glue and adhesive etc.
3. The pump can suck various glazed slurries of tile, porcelain, brick and chinaware etc.
4. The pump can suck various grinding materials, corrosive agent and clean the oil dirt etc.
5. The pump can suck various toxin and flammable or volatility liquid etc.
6. The pump can suck various wedge water, cement slurry and mortar etc.
7. The pump can suck various strong acid, alkali and corrosive liquid etc.
8. It can be used as a front-step tranmission device of the solid and liquid separation equipmen


Air Operated Diaphragm Pump Specifications

Air Diaphragm Pump
1. Non leakage
2. Good self priming performance
3. Convey all kinds of medium
4. Material:Cast steel,Alu,SS,PP



A 50 X X - X X X - X (model selection)

Form of pipe mouth:A-BSP B-NPT(F) C-Flange
Diaphragm material:9 – Santoprene H – Hytrel T - PTFE/Santoprene
Ball material:9 -Santoprene H – Hytre T – PTFE A - Acetal
Ball seat material:P/K –Polypropylene/Kynoar SS –Stainless Steel
Pump material: SS –Stainless Steel AL –Aluminum Alloy CI- Carbon Steel P/K –Polypropylene/Kynoar








Requirements for Air and Lubrication

EXCESSIVE AIR PRESSURE. Can cause pump damage, personal injury or property damage.

  • A filter capable of filtering out particles larger than 50 microns should be used on the air supply. There is no lubrication required other than the “O” ring lubricant which is applied during assembly or repair.
  • If lubricated air is present, make sure that it is compatible with the “O” rings and seals in the air motor section of the pump.




OPERATING INSTRUCTIONS

  • Always flush the pump with a solvent compatible with the material being pumped if the material being pumped is subject to “setting up” when not in use for a period of time.
  • Disconnect the air supply from the pump if it is to be inactive for a few hours.
  • The outlet material volume is governed not only by the air supply but also by the material supply available at the inlet. The material supply tubing should not be too small or restrictive. Be sure not to use hose which might collapse.
  • When the diaphragm pump is used in a forced -feed (flooded inlet) situation, it is recommended that a “Check Valve” be installed at the air inlet.
  • Secure the diaphragm pump legs to a suitable surface to insure against damage by vibration.

Maintenance

  • Please refer to the component schematic in the assembly drawings to look up the serial numbers and names of parts and grasp the information of parts and maintenance service pack.
  • Some BSK parts are marked as "wearing parts", which can conduce to quick service and downtime reduction.
  • Service kits are divided to service two separate diaphragm pump functions: 1. AIR SECTION, 2. FLUID SECTION. The FLUID SEC -TION is divided further to match typical part MATERIAL OPTIONS.
  • Provide a clean work surface to protect sensitive internal moving parts from contamination from dirt and foreign matter during service disassembly and reassembly.
  • Keep good records of service activity and include pump in preven -tive maintenance program.
  • Before disassembling, empty captured material in the outlet man -ifold by turning the pump upside down to drain material from the pump.
China No Leakage Air Operated Diaphragm Pump Shut - Off Valves CE Approved supplier

No Leakage Air Operated Diaphragm Pump Shut - Off Valves CE Approved

Inquiry Cart 0