Home /Power Distribution Equipment /

Underground Cable Fault Distance Locator , Distribution Cable Fault Detector 8G Storage

Underground Cable Fault Distance Locator , Distribution Cable Fault Detector 8G Storage

Brand Name:Fanke High-voltage
Certification:ISO9001
Model Number:FKDL2000
Minimum Order Quantity:One Unit
Delivery Time:10-15 Working Days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
Supplier`s last login times: within 39 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Underground Cable Route and Cable Fault Distance Locator, Distribution Cable Fault Detector

I. Application :

FKDL2000 cable fault distance locator is a kind of Integrated testing apparatus , which is made from the fault detecting test host, cable path tracing signal generator, cable tracing path signal receiver and cable fault locator, etc.The host machine, including the integrated computer, the low-voltage pulse generator, and the data processor, is used to test fault distance and measure cable length and wave propagation velocity in cable.The sine wave signal with frequency of 30KHz and amplitude peak of 30V produced by path signal generator is used to find the cable path.Path signal receiver is used for receiving the signal path, and used to find the cable louding and estimate the cable burial depth. Fault locator is used for fault exact positioning.The detecting way of the has three kinds of LV impulse method, impulse HV flash-over method, multiple pulse method. The optional part is DC high voltage booster and control cabinet , which is used for providing a breakdown voltage to enlarge the insulation damaged and easily repairing .

The Integrated testing apparatus is able to test cable fault at different voltage levels below 35KV. It can test cable fault of different cable sections, different dielectric and different cable materials. Can test open-circuit cable fault, short-circuit cable fault, low-resistance cable fault, high-resistance leakage cable fault and high-resistance flash-over cable fault.

II. Technical index:

1, Fault measuring system

  • Test various types of faults of power cables and open circuit or short-circuit faults of coaxial communication cable and telephone cable.
  • Tested cable class: 35KV and below
  • Measure the speed of radio wave propagation in cables whose length is known.
  • Measuring distance:more than 16 km
  • System error:less than 1m
  • Sampling frequency:25 MHz
  • Min. resolution:0.2m
  • Dead zone:less than 16m
  • Power:DC 12V
  • Weight:5 Kg

2, Cable Tracing Path signal generator Part

  • Signal output frequency:30 KHz
  • Oscillating method:chopping
  • Power output:30W
  • Power:220V±10%
  • Weight:4 Kg


3, Cable Fault Locator Part

  • Measuring sensitivity: Signal source with internal resistance of 50Ω outputs 300 Hz signal, the locator inputs signal less than 10μv when the output is 2V and the signal to noise ratio is better than 20:1.
  • Impedance input:more than 1.2KΩ
  • Earphone of 2×2000Ω
  • Operating voltage :DC 9V±10%
  • Ambient temperature:-20℃~70℃

4. Other Technical Data

ModelFKDL2000
Application

Can test cable fault at different voltage levels below 35KV. Can test cable fault of different cable sections, different dielectric and different cable materials. Can test open-circuit cable fault, short-circuit cable fault, low-resistance cable fault, high-resistance leakage cable fault and high-resistance flash-over cable fault.

Cables

Can test all faults of railway communication control cable, streetlight cable and airport signal cable.
Can test wave transmitting velocity in any cable of known length.
Can test buried route and depth of power cable

Display mode12.1in industrial LCD touch screen (Windows XP platform)
Test methodLV impulse method, impulse HV flash-over method, multiple pulse method
Storage8G
Test distanceno less than 60Km
OperateTouch pen and mouse
Min. test distance (non-detection area):0-5m or without
Locating error±0.2m
Test errorsystem error is no ore than ±1%
Multiple pulse generatorImpulse voltage ≤40KV
ResolutionV/fm,V is transmitting velocity m/μs
software cursor0.10m.
Sampling frequency6.25MHz,12.5MHz,25MHz,50MHz,100MHz (Adaptive pulse width).
Power source and power consumption

AC 220V±10%, power consumption≤15W
DC 12V(7AH), power consumption≤20W

Standby timecontinuous working 6 hours
Host weight6.2KG
Dimension:180mm×300mm×400mm
Temperature-20℃- 40℃
Relative humidity≤80%



III. Configuration:

  • FKDL Cable fault test system (1 set)
  • FKDL Path signal generator (1 set)
  • Path Signal receiver (1 piece)
  • FKDL Fault Locator (1 piece)
  • Current sampling cabinet (1 piece)
  • Discharging sphere gap (1 set)
  • Earphone (2 pieces)
  • DC Impulse capacitor (1 set)

















China Underground Cable Fault Distance Locator , Distribution Cable Fault Detector 8G Storage supplier

Underground Cable Fault Distance Locator , Distribution Cable Fault Detector 8G Storage

Inquiry Cart 0