Product Details
CT PT Analyzer ELECTRICAL 3000A PRIMARY CURRENT INJECTION TEST
EQUIPMENT
TEST-903 primary current injection test kit adopts ARM chip to
control the output process and large capacity of toroidal
transformer. It is equipped with LCD screen display current meter,
also showed primary current value, secondary current value, turn
ratio and the phase shift. Aluminum alloy body with PC panel
component the shell.
TEST-903 is mainly applied to test CT turn ratio and polarity in
the power system, the contact resistance, high voltage circuit
breaker protection test and high voltage generator test etc, which
need large current on-site or in the lab.
High-current generator is a necessary equipment in all walks of
life in electrical commissioning needs
large current place, used in power plants, substations, electrical
manufacturers and scientific research,
laboratory and other units, belonging to short-term or intermittent
working system, It has a small size, light
weight, good performance, easy to use and maintenance features.
- Permanent current up to 3000 A, 15KVA
- Max current output up to 3300A.
- Built-in digital ammeter 0.5% accuracy.
- Built-in digital timer resolution 1 ms (Optional).
- Made up of two units, control and power unit
- Thermal and short-circuit protection.
PARAMETERS
| Electrical parameters |
|---|
| Accuracy | ±0.5% |
| Power Supply(AC) | 380V·50A, 50Hz/60Hz |
| Current Output (AC) | 3000A·5V or 1500A·10V |
| Capacity | 15KVA |
| The current output waveform distortion | ≤5% |
| Primary current |
|---|
| Range | 0-3300A |
| Resolution | 0.1A |
| Accuracy | <0.5% |
| Secondary measurement |
|---|
| Range | 0-6A |
| Resolution | 0.001A |
| Accuracy | <0.5% |
| Current duration |
|---|
| 3000A range | 3000A 2-3minutes 1500A 3-6minutes |
| 1500A range | 1500A 2-3minutes |
| With timer |
|---|
| Range | 0.0001~999.99S |
| Resolution | 0.001S |
| Accuracy | <0.5%±5 words |
| Mechanical parameters |
|---|
| Dimensions (W×D×H) (mm) | 380×350×360 and 340×290×420 |
| Weight(kg) | Control Host 48kg, External voltage regulator weight 42kg |
| Environmental conditions |
|---|
| Temperature | -10°C to 40°C |
| Relative humidity | ≤80% |
SELECTION GUIDE
| Model | ACCU RACY | Primary current | AMMETER (0-6A) | TIMER | POWER | INJECTION CURRENT TIME | DIMENSION(W×D×H)(mm) | WEIGHT | REMARK |
|---|
| TEST-901 | 0.5% | 0-1100A | YES | YES | 5KVA | 1000A: 2-3min; 500A:3-6min | 430×260×260 | 25KG | Integrated structure |
| TEST-902 | 0.5% | 0-2200A | YES | OPTIONAL | 12KVA | 2000A:2-3min; 1000A:3-6min | 360×300×295 and 320×300×300 | 35KG+15KG | Fission structure |
| TEST-903 | 0.5% | 0-3300A | YES | OPTIONAL | 15KVA | 3000A:2-3min; 1500A:3-6min | 380×350×360 and 340×290×420 | 48KG+42KG | Fission structure |
| TEST-905 | 0.5% | 0-5500A | YES | OPTIONAL | 25KVA | 5000A:2-3min; 2500A:3-6min | 430×430×445 and 550×450×600 | 68KG+55KG | Fission structure |
Company Profile
Beijing GFUVE Instrument Transformer Manufacturer Co., Ltd. was
established in 2008. It combined design, manufacturing and sales
together as one high-tech enterprise. GFUVE Instrument Transformer
company mainly produces less than 35kV current transformer and
voltage transformer, split core ct and current clamp models etc.
GFUVE is a leader manufacturer of split core current transformer
products in China. It is professional in current transformer,
potential transformer and related accessory. The product of outdoor
split core current transformer develops very quickly in the global
market. Our company has achieved certification to ISO9001. The
products are sold to over 30 provinces in China and exported to
overseas including South America, Middle East, Southeast Asia,
Australia and Africa.
Please contact us now for further business relationship. We are
here to provide you the best service and the best product.