Home /Contactors /

3RT6016 IEC Contactor 7 9 12 25 32 40 50 63 80 185A AC-3 AC-1 Coil Voltage 24V 110V 230V 380V

3RT6016 IEC Contactor 7 9 12 25 32 40 50 63 80 185A AC-3 AC-1 Coil Voltage 24V 110V 230V 380V

Brand Name:SIEMENS
Certification:CE,CCC etc.
Model Number:3RT
Minimum Order Quantity:1 Unit
Delivery Time:5-8 working days or bulk order negotiate
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Wuxi Jiangsu China
Address: 606#, Building-B, 100 Dicui Road, Binhu District, Wuxi, Jiangsu, China
Supplier`s last login times: within 26 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

SIEMENS 3RT6016,IECContactor 7A,9A,12A,25A,32A,40A,50A,63A,80A up to 185A, AC-3 AC-1 Coil Voltage 24V,110V,230V,380V


characteristic
• Current range 07~185A;
• AC, DC control coil is optional;
• Different types of starters are available: standard motor start contactors, reversible contactors, star-delta starters, autotransformer starters, etc.
• Product Certification: CCC, CE, CCS;


Advantage
• Compact installation
> Surge suppressor installation requires no tools and can be inserted directly into the contactor without taking up more space
> Reversible contactor is only 90mm wide, mechanical interlocking does not take up extra space, installation takes almost no time
> Starter components provide pre-wired modules for quick and easy assembly
• Highly integrated
> to 100A contactor integration 1 normally open / 1 normally closed auxiliary contact
> DC coil with built-in bidirectional suppression diode
> Reversible contactor group with built-in bidirectional suppression diode
• Safe and reliable
> The main circuit and control circuit of the control and protection components are clearly distinguished
> Mirrored contact design that meets safety standards, ensuring 10 million reliable actions
> Protective cover prevents accidental contact of the contactor
• outstanding quality
> DC coils have a wide range of control voltages (0.7~1.25Uc)
> Strong earthquake resistance
> lower noise
> Increased terminal strength

> Permanent torque, reliable installation
> Compact and space saving
> Easy to install, saves time

> Easy to maintain and save costs

main information

Product Series

3RT

product name

AC Contactor

product type

Contactor

Product short name

3RT

Contactor application area

Applied to AC loads with a power factor greater than or equal to 0.95
Squirrel cage motor for switching on and off normal start

Use category

AC-3
AC-1
AC-4

Number of poles

3P

Power pole contact composition

3 NO

Rated working voltage [Ue]

Power circuit: <= 690 V AC 25...400 Hz
Power circuit: <= 300 V DC

Rated operating current [Ie]

18 A 60 °C) on <= 440 V AC AC-3 Applicable power circuit
32 A 60 °C) on <= 440 V AC AC-1 for power supply circuit

Motor power (kW)

4 kW on 220...230 V AC 50/60 Hz (AC-3)
7.5 kW on 380...400 V AC 50/60 Hz (AC-3)
9 kW on 415...440 V AC 50/60 Hz (AC-3)
10 kW on 500 V AC 50/60 Hz (AC-3)
10 kW on 660...690 V AC 50/60 Hz (AC-3)
4 kW on 400 V AC 50/60 Hz (AC-4)

Motor power HP (UL / CSA)

1 hp on 115 V AC 50/60 Hz for 1-phase motors
3 hp on 230/240 V AC 50/60 Hz for 1-phase motors
5 hp on 200/208 V AC 50/60 Hz for 3-phase motors
5 hp on... 230/240 V AC 50/60 Hz for 3-phase motors
10 hp on 460/480 V AC 50/60 Hz for 3-phase motors
15 hp on 575/600 V AC 50/60 Hz for 3-phase motors

Control loop characteristics

AC on 50/60 Hz

Control loop voltage

230 V AC 50/60 Hz

Auxiliary contact type

1 NO + 1 NC

Rated impulse withstand voltage [Uimp]

6 kV in accordance with IEC 60947

Overvoltage category

III

Conventional heating current [Ith]

10 A on <60 °C for signal circuit
32 A on <60 °C for power supply circuit

Rated turn-on capability [Irms]

140 A AC suitable signal circuit in accordance with IEC 60947-5-1
250 A DC suitable signal loop in accordance with IEC 60947-5-1
300 A on 440 V applicable power supply circuit in accordance with IEC 60947

Rated breaking capacity

300 A on 440 V applicable power supply circuit in accordance with IEC 60947

Rated short-time withstand current [Icw]

145 A on <40 °C - 10 s for power supply circuit
240 A on <40 °C - 1 s for power supply circuit
40 A on <40 °C - 10 minutes for power circuit
84 A on <40 °C - 1 minute for power circuit
100 A - 1 s for signal circuits
120 A - 500 ms Applicable signal loop
140 A - 100 ms for signal circuits

Fuses used with relays

10 A gG Applicable signal circuit in accordance with IEC 60947-5-1
50 A gG on...<= 690 V with type 1 for power supply circuit
35 A gG on ...<= 690 V with type 2 for power supply circuit

Average impedance

2.5 mΩ - Ith 32 A 50 Hz for power supply circuits

Rated insulation voltage [Ui]

Power circuit: 690 V in accordance with IEC 60947-4-1
Power circuit: 600 V CSA certification
Power circuit: 600 V UL certification
Signal loop: 690 V in accordance with IEC 60947-1
Signal loop: 600 V CSA certified
Signal circuit: 600 V UL certification

Electrical life

1.65 kA2.s 18 A AC-3 Ue condition <= 440 V
1 kA2.s 32 A AC-1 Ue condition <= 440 V

Power consumption per pole

2.5 W AC-1
0.8 W AC-3

Safety cover

band

Installation method

Rail mounting
Base plate installation

standard

CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508


China 3RT6016 IEC Contactor 7 9 12 25 32 40 50 63 80 185A AC-3 AC-1 Coil Voltage 24V 110V 230V 380V supplier

3RT6016 IEC Contactor 7 9 12 25 32 40 50 63 80 185A AC-3 AC-1 Coil Voltage 24V 110V 230V 380V