Home /Other Chemical Reagents /

100% Sensitivity 10 Minutes HCV Hepatitis Rapid Test Kit

100% Sensitivity 10 Minutes HCV Hepatitis Rapid Test Kit

Brand Name:Newscen
Certification:ISO9001, CE, TUV, FDA
Model Number:HCV (Hepatitis C Virus)
Minimum Order Quantity:10 Boxes or 400 Kits (40 Kits/Box)
Delivery Time:8 days
Payment Terms:T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Site Member
Location: Tianjin Tianjin China
Address: No. 65 Sixth Ave .,TEDA Tianjin , 300457 P. R. China
Supplier`s last login times: within 22 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

HCV(Hepatitis C Virus) Antibody Rapid Test Kit


For the qualitative detection of HCV antibodies in serum/plasma and whole blood


Intended Use


Newscen HCV Antibody Rapid Test is for the detection of antibodies to Hepatitis C type virus(HCV) in human serum, plasma or whole blood collected from vein or fingertip. It is intended for use in medical institutions by trained staff.



Principle


HCV(Core and NS 3) specific recombinant antigens are precoated on to the membrane as the capture reagent on the test zone. During the test, specimen is allowed to react with the colloidal gold particles,which have been conjugated with HCV specific recombinant antigens. Antibodies to HCV, if present, will specifically bind to colloidal gold-antigen complex. When the colloidal gold-antigen-antibody complexes move to the test zone, they will specifically bind to the precoated antigens. At the same time, a red colored I in e will develop in the test zone. Absence of this red colored line in the test zone suggests a negative result. To serve as a procedural control, red colored line in the control zone will always appear regardless of the presence of antibodies to HCV.


Reagents and Materials Provided


Each Kit Contains:


40 test cassettes(individually pouched)

Each pouch contains one cassette with one desiccant bag

One bottle of diluent buffer(5mL)

40 disposable plastic droppers

Instruction for use



Materials Required But Not Provided


Timer or stopwatch

Blood collection devices, for the testing of venipuncture whole blood, serum or plasma

Biohazard disposal container

Disposable gloves


For finger stick samples, the following materials are required:


Alcohol pad

Sterile lancet

Sterile gauze or cotton


WARNING


For invitro diagnostic use ONLY


Storage


Newscen HCV Antibody Rapid Test should be stored at 4-30°C(do not freeze) for 24 months from the date of manufacture. Keep the test cassette in sealed pouch until use. Once you have taken the test cassette out of the pouch, perform the test as early as possible(within 1hour) to avoid test cassette from becoming moist. Do not use the test beyond the indicated expiration date.


The diluent buffer should be stored at 4-30°C(do not freeze) for 24 months from the date of manufacture. After the diluent is opened, it will be stored for 24 months according to the validity period.



Sample Collection and Test Preparation


Finger stick Specimens(Whole Blood)

Clean the area to be lanced with an alcohol pad.

Squeeze the end of the fingertip and pierce it with a sterile lancet.

Wipe away the first drop of blood with sterile gauze or cotton;collect the sample from the second drop.

Use dropper to draw the fresh blood to 1/ 2 of the tube wall and dispense into the sample well.


Finger stick whole blood should be used immediately after collection.

Serum/Plasma specimens:fresh serum or plasma specimen can be used. No special patient preparation required.


Plasma

Collect whole blood into a collection tube(containing EDTA, Na-citrate or heparin) by venipuncture.

Separate the plasma by centrifugation.


Serum

Collect whole blood into a collection tube(containing no anticoagulants) by venipuncture.

Allow the blood to clot.

Separate the serum by centrifugation.


Venipuncture Whole Blood

Venipuncture whole blood can be used immediately after collection or store dupto4daysat 2-8℃.



Assay Procedure


Place the test cassette on flat surface. Before unseal the pouch, allow the test cassette to reach laboratory temperature(15-30°C) .Use it immediately once unsealed.

Open the pouch and add1dropor35pL of specimen into the sample well(S) .

After adding the specimen, add1dropor35pL of diluent buffer vertically into the sample well(s) immediately.

Avoid dropping specimen or diluent buffer in the observation window.

Do not allow the diluent buffer bottle touch the sample well when dropping the diluent buffer so as to prevent the cross contamination with the specimen.

Observe the result in 30 minutes once the diluent buffer added.



Built-In Control


Newscen HCV Antibody Rapid Test has a built-in procedural control that demonstrates assay validity. A redline appeared on the control zone(C) indicates that the test runs correctly.




China 100% Sensitivity 10 Minutes HCV Hepatitis Rapid Test Kit supplier

100% Sensitivity 10 Minutes HCV Hepatitis Rapid Test Kit

Inquiry Cart 0