Home /Energy Meters /

HS3103 Portable Meter Test Equipment(Electric Energy)

HS3103 Portable Meter Test Equipment(Electric Energy)

Brand Name:Shengdi Electrical
Certification:ISO9001:2008
Model Number:HS3103
Minimum Order Quantity:1 set
Delivery Time:35 days
Payment Terms:TT/LC
Contact Now

Add to Cart

Active Member
Address: #8,Zhenghua Road,Wuyuan Industry Zone,Haiyan County
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

HS3103 Portable 1 Phase Energy Meter Test Equipment

Technical specification

1. Electrical output

1) Voltage and current measurement range

Output voltage ranges: 57.7V/63.5V and 220V/240V (480V option)

Output current ranges: 0.1A, 1A, 5A, 20A, and 100A

2) Output load capacity

Voltage loop: Max. 50VA

Current loop: Max 100VA (Measurement range 100A)


2. Electrical output adjustment

1) Voltage adjustment

a) Adjustment range: 0%~125% selected voltage range

b) Adjustment fineness: four finenesses as 10%, 1%, 0.1%, and 0.01% are

available

c) Max. output voltage: 300V or 600V

2) Current adjustment

a) Adjustment range: 0%~120% selected current range

b) Adjustment fineness: four finenesses as 10%, 1%, 0.1%, and 0.01% are

available

c) Max. output current: 120A

3) Phase adjustment

a) Adjustment fineness: 0°~359.99°

b) Adjustment fineness: four finenesses as 10°, 1°, 0.1°, and 0.01° are

Available


3. Voltage and current output distortion

This device’s voltage and current output distortion will not be more than 1%

(testing under linear load)


4. Output power stability

This device’s pre-set output power will not exceed 0.05% compared with the

measurement range variation within 180S.


5. Harmonic content

a) Number of harmonic waves: 2~31

b) Harmonic content: less than 40% (compared with fundamental wave)

c) Harmonic phase: 0°~359.99°


6. Monitoring instrument

To be read directly from the standard meter.


7. Electric pulse

Electric pulse output from standard meter:

1) For error calculator to calculate the error of any meter to be tested;

2) For the reference of upper-level measurement examination and

determination agency when sending the standard meter to them for testing.

Please refer to standard meter’s Table of Constants for pulse constants.


8. Power supply

Single-phase AC 220V/240V (100V/110V/230V is also applicable), 50/60Hz,

max. input power consumption: 500W.


Contact: Yeli

Email: hysdsales@gmail.com

Skype: lily19850618



China HS3103 Portable Meter Test Equipment(Electric Energy) supplier

HS3103 Portable Meter Test Equipment(Electric Energy)

Inquiry Cart 0