HS-6303E three-phase energy meter testing bench

SUIT FOR "CT &DC METER" & Single-phase/Three-phase meter


Overview:


HS-6303 three-phase energy meter testing bench adopts SPWM digital power source technology, comprises high grade standard digital watt-hour meter, multi-path voltage transformer, can implement multi-station high accuracy error testing.

This testing bench configurates humanized PC processing software, can provide integrated solution of the energy meter automatic check. Meanwhile, it provides the requested DLL of the second development, has improved the self-control and management for the bench by customer.

This testing bench can be widely used for the energy meter measurement and testing in electric power, water conservancy, traffic transportation and colliery departments, as well as the energy meter testing and production of the energy meter manufacturer.

This series of testing bench can test all kind of single phase energy meters, single phase multi-function meters, single phase intelligent meters, other meters with special wiring and ANSI standard meter. It is an ideal new generation multi-station energy meter testing device.


Functional advantage:

  • base on A/D and DSP technology
  • adopt precise digital synthesized technology and sine PWM technology
  • adopt intelligent system control technology, multi-CPU coprocessing technology
  • reliable multi-path pulse testing and precise error testing treatment technology
  • SPWM technology power amplifier, large capacity, high performance, low power consumption, automatic warning protection
  • Error processor of each station distributed networking, heavy current protection, support multi-path pulse signal input
  • Can configurate serial server, implement parallel communication of multi-station, improve work efficiency
  • Modular design, have good universality of parts, easy to disassemble and maintain
  • One-button checking and control management system, automatic finish as per the project
  • Standard cabinet, aluminum alloy frame, nicer and stronger
  • Customized as per specific function

Technical Parameters:


Parameter Item0.020.050.1
Reference standard energy meterHS-5300H 0.02HS-5300 0.05HS-5300 0.1
Output range

Voltage:3×30~300V

Current:3×1mA~120A

Voltage:3×30~300V

Current:3×10mA~120A(200A Option)

Output phase shift0~360°,resolution:0.01°
Output frequency45~65Hz ,resolution:0.01Hz
Waveform distortionBoth Voltage and current<0.5%( relative liner load)
Voltage &current power stability

<0.02%/120s

<0.05%/120s

<0.1%/120s

Output capacity

Voltage:300VA(6 stations)

Current:250VA(120A)

Voltage:300VA(16 stations)current:900VA(120A)
if add meters, Max. current: 2000VA,Max. voltage: 1200VA

Load characteristicsResistive, inductive and capacitive(less than 1uF/station,Max. less than 48 uF)
Starting up current outputMin.1mA(0.3mA optional),accuracy:5%,starting power:accuracy 5%
sampling pulse input≤1kHz
Communication testingRS485/232/ infrared/carrier wave, support DL/T645-1997/2007,IEC1107
Number of energy meters to be tested6/16(standard),3-60 (optional)
Environment conditiontemperature:20℃±5℃;humility:<85% R.H.
Power supply

AC220 ±10%,50/60Hz,AC120/240V(optional);
Max. power consumption:3000VA(24 stations)


Dimensions(unit:mm)

IntegrationstationsNumber of rackdimension:L×W×HFissionstationsNumber of rackdimension:L×W×H
612000×800×16001212000×700×1920
CUSTOM1612200×700×1920
1212000×800×19202422000×700×1920
1612200×800×19203222200×700×1920
2422000×750×1920cabinet600×800×1920

Type & specification

TypeDescriptionRange of application
HS-6303three-phase energy meter testing benchStandard energy meter testing
HS-6303Bthree-phase multi-function energy meter testing benchMulti-function energy meter testing
HS-6303Cthree-phase horizontal energy meter calibration benchEnergy meter error calibration
HS-6303Ethree-phase energy meter test bench with ICTS1P3W energy meter testing
HS-6303Fthree-phase intelligent energy meter testing benchintelligent energy meter testing
HS-6303Gthree-phase energy meter (round meter) testing benchStandard energy meter testing
HS-6303Mthree-phase din-rail energy meter testing benchMulti-function energy meter testing
HS-6303Hthree-phase high precision energy meter testing benchEnergy meter error calibration

Function parameters:

Function item

HS-6303

HS-6303B

HS-6303C

HS-6303E

HS-6303F

HS-6303G

HS-6303M

HS-6303H

Base testing

functions

Base error
Creep testing
Starting up testing
standard deviation
Constant calibration
Counting error
Influencing testing
Multi-function testingDaily timing error☆
Period switching
Demand period error
Demand display error
Energy display error
register checking
GPS clock synchronization☆
Communication testing☆
  • :●─standard;〇─optional.

For Item ☆ need special function parts


Bench configuration

Type

HS-6303

HS-6303B

HS-6303C

HS-6303E

HS-6303F

HS-6303G

HS-6303M

HS-6303H

Standard energy meter
power source
error processing system
multi-path pulse input
Auto searching mark
auto short circuit
ICT
parallel communication
carrier communication
IR communication
power consumption testing
DC and even harmonic wave
standard clock tester
GPS clock synchronization
collective turn over & optoelectronic sampling
  • :●─standard;〇─optional

Products Details:


Cabinet (Power source + Reference Meter + Signal Source)

Test Rack(Quick connector,scanning head,communication wire,error precessor,etc.)

BACK OF TEST RACK.

ISOLATED CURRENT TRANSFORMER(ICT)


China 16 Positions Three Phase Electric Electricity Energy Meter Test Bench,0.05% accuracy class,Max.120A current output supplier

16 Positions Three Phase Electric Electricity Energy Meter Test Bench,0.05% accuracy class,Max.120A current output

Inquiry Cart 0