Product Details
Application:
>>Digital signal to analog signal,DA transform
>>Isolated 4-20mA or 0-20mA signal transmission
>>Signal isolation and conversion of industrial site
>>PWM signal without distortion transmission
>>Instrument signal transceiver
>>Power monitoring, medical equipment isolation
>>Ground interference suppression
>>PLC / FA motor control signal isolation
>>Pulse width measurement
PWM signal to 4-20ma/0-10V isolated converters
Features:
>>Accuracy grade: 0.2/0.5. Factory calibrated,the user can
use directly
>>Auxiliary power supply: 5V/12V/15V/24VDC
>>PWM pulse width modulation signal input:50Hz~100KHz
>>International standard signal output: 0-5V / 0-10V/1-5V,
0-10mA / 0-20mA/4-20mA
>>High linearity (non-linearity <0.2%)
>>Three-port 3000VDC isolation:input/power supply/output
>>DIN35 rail mounting
>>Size: 79.0x69.50.0x25.0mm
>>Strong anti-electromagnetic interference and high-frequency
signal interference capability
>>CE approved
Products Listing:
DIN11 IAP – PWM□ - P□ - V/A□
Input Signal | Power | Output Signal |
PWM signal | code | Power | code | current | code | voltage | code |
50~99Hz | PWM1 | 24VDC | P1 | 0-20ma | A3 | 0~5V | V1 |
100Hz~900Hz | PWM2 | 12VDC | P2 | 4-20ma | A4 | 0-10V | V2 |
1KHz~9KHz | PWM3 | 5VDC | P3 | user-defined | Az | 1-5V | V6 |
10KHz~100KHz | PWM4 | 15VDC | P4 | | | user-defined | Vz |
user-defined | PWMz | | | | | | |
samples:
1:Input signal:100Hz PWM Power supply:24V Output signal:4-20mA
Type No.: DIN11 IAP-PWM2-P1-A4
2:Input signal: 5KHz PWM Power supply:12V Output signal:0-10V
Type No.: DIN11 IAP-PWM3-P2-V2
3:Input siganl: 20KHz PWM Power supply:24V Output signal:4-20mA
Type No.: DIN11 IAP-PWM4-P1-A4
General Parameters:
Name | Test Condition | Min. | Type | Max. | Units |
Isolation Voltage | 50Hz,1min.,leak current 1mA | | 2500 | | VDC |
Iaolation | Input/power supply/output |
Impact Voltage | 3KV, 1.2/50us(peak value) |
Operation Temperature | | -25 | | +70 | ℃ |
Operation Humidity | No condensation | 10 | | 90 | % |
Storage Temperature | | -45 | | +80 | ℃ |
Storage Humidity | | 10 | | 95 | ℃ |
Company Profile
Shenzhen WAYJUN Industrial Automation is a HI-tech company of
designing, researching 4-20mA/0-5V to RS485 Data Acquisition
Module,analog signal isolated converter / conditioners,Ethernet I/O
Module,PT100 temperature /speed/frequency signal
isolators/splitter,isolated amplifier,Digital Signal to RS485/232
Module,Min-power DC DC converters.Our products also carry the CE
approval for safety.
WAYJUN's products are widely used in the industry power fields of
control, electric power, electronic instrument, medical electronic,
rail transit, communication, telecom, automation,Medical and Test
& Measurement etc.Our products are sold all over the
world.Create maximum value for customers is our constant aim.More
details,please check: www dot wayjun dot net.
WAYJUN products series:
1. Remote I/O isolation module
WJ21 series -------- 4-20mA/0-10V to RS485/232 AD converter
WJ31 series -------- RS485/232 to 4-20mA/0-10V DA converter
WJ28 series -------- 8 channels 4-20mA/0-10V to RS485/232 AD
converter
WJ70 series -------- 4-ch DI 4-ch relay output, RS485/232 remote
data acquisition module
WJ61 series --------16-ch DI switch / dry contact signal to
RS485/232
WJ62 series -------- 8-ch DI switch signal to RS485/232 remote I/O
modules
WJ60 series -------- 8-ch DI 8-ch DO switch to RS485/232 remote I/O
modules
2. Analog signal isolator / transmitter:
DIN35 rail-mounted
DIN11 IAP-V (A) -P-V (A) ---- photoelectric isolation signal
transmitter (one in one out)
DIN12 IAP-V (A) -P-V (A) ----- voltage / current signal splitter
(one in two out)
DIN14 IAP-V (A) -P-V (A) ----- voltage / current signal splitter
(one in four out)
DIN22 IAP-V (A) -P-V (A) ----- voltage/current signal isolated
transmitter(two in two out)
DIN44 IAP-V (A) -P-V (A) ------ voltage/current signal isolated
transmitter(four in four out)
WJ11 IAP-Z-T-P-A (V) ----------- PT100 thermal resistance
temperature signal isolation transmitter
DIN22 IAP-Z-T-P-A (V) ----------- PT100 thermal resistance
temperature signal isolation transmitter (two out of two)
DIN12 IAP-Z-T-P-A (V) ----------- PT100 thermal resistance
temperature signal isolation splitter (one in two out)
DIN11 IAP-F-P-V (A)-----------frequency to voltage / current signal
isolated transmitter
DIN11 IAP-V (A) -P-F----------voltage / current signal frequency
isolation transmitter
DIN11 IAP-R-P-V (A) --------- Potentiometer /resistance signal
isolated transmitter
DIN11 IAP-S-P-O-----------speed sensor signal isolated transmitter,
sine waveshaping
DIN33 IAP-S-P-O------------------- encoder differential signal to
pulse signal transmitter
DIN11D IAP-V (A) -P-V (A) -------- large current output signal
isolator
DIN11 IAP 4-20mA------------------4-20mA passive signal isolator
DIN22 IAP 4-20mA------------------4-20mA passive signal isolator
(two in two out)
DIN11 IAP 100LF-------------------- passive isolation 4-20mA signal
distributor
DIN11 IAP 100LP-------------------- passive isolation 4-20mA signal
conditioner
In addition, DC voltage / current signal isolators also have PCB
package.