Home /Passive Components /

Single Phase Split Din Rail Prepayment Power Meter With CIU Pole Mounting

Single Phase Split Din Rail Prepayment Power Meter With CIU Pole Mounting

Brand Name:Radarking
Certification:IEC, STS
Model Number:RDK DDSK150
Minimum Order Quantity:500 pcs
Delivery Time:15-20 working days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: No.270, Huangjinkou 3rd Village, Hanyang District, Wuhan City, Hubei Province, China
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Single Phase Split Din Rail Prepayment Power Meter With CIU Pole Mounting


DDSY150 is used for a wide rang of applications, due to an improved dynamic range allowing a
basic current of 5 Amp while retaining a maximum current of 80 Amp and extended functional features. It is a compact and keypad based design in a BS8565 standard housing and maintains the
rugged RF immunity withstand of 30V/m and IP54 rating, allowing it to be installed in harsh environments.

Main Features

  • 20 digit (Standard Transfer Specification) STS encryption
  • Detection of significant reverse energy (SRE)
  • IEC62056-21 compliant optical & RS485 port allowing for easy data interrogation
  • Disconnects on overload and no credit
  • Prepayment and credit mode hot swap
  • Programmable load limit and low credit warning
  • Detection and record tamper event such as opening cover, reverse connection, black-out
  • Easy access to 12 months historical consumption data and last 5 token entered


AMR/AMI Smart Metering Function (on request)

  • Easy connection to User Interface Unit (UIU) for split type applications
  • PLC/ RF / GPRS communication with a head-end AMR/AMI server
  • Time of Use (TOU) , multi-tariff, holiday setting.
  • Advanced load control and disconnection features

Specifications:


Nominal voltage Un220/230/240 V
Limited voltage70%~120%Un
Nominal frequency fn50-60Hz+5%
Basic current(Ib)5-10A
Maximum current(Imax)60-100A
Starting current(Ist)20mA
Active energy constant1000imp/kWh
Accuracy as Active energy to IEC62053‐21Class1.0
Power consumption in Voltage circuit<2W <8VA
Power consumption in current circuit<1VA
Operating temperature25℃ to+70℃
Storage temperature40℃ to+85℃
Insulation level4kV rms for 1min
Impulse voltage withstand8kV, 1.2/50 μs
Air discharge16kV
Immunity to HF fields
80MHz to 2GHz with load10V/m
100kHz to 1GHz without load30V/m
Fast transient burst test4kV
Meter shell Protection RateIP54(IEC60529)
Insulation System Classification

Protective Class II


Safety precautions:


- Use only isolated tools.
- Do not connect the meter to a 3 phase - 415V AC - network.
- Place the meter only in dry surroundings.
- Make sure the used wires are suitable for the max current the meter can measure.
- Make sure the AC wires are installed correctly before activating the current/voltage.
- Do not touch the meter connecting clamps directly with your bare hands, with metal, blank wire or other material as you will have the chance of an electricity shock and a possible chance for health damage.
- Make sure the protection cover is placed after installation and has been sealed.
- Installation, maintenance and repair should only be done by a certified electrician.
- Never break the seals or open the front cover as this might influence the functionality of the meter.
- Do not through, drop, kick or other physical violence to the meter as there are high precision components inside that will break or make the meter measure inaccurate.
- Do not mount the meter in area's with harm gas, dust, mildew or insects or on unstable surfaces.


China Single Phase Split Din Rail Prepayment Power Meter With CIU Pole Mounting supplier

Single Phase Split Din Rail Prepayment Power Meter With CIU Pole Mounting

Inquiry Cart 0