Home /Active Components /

DN15 / 20 / 25mm LoRaWAN Smart Water Meter 165 X 85 X 111mm

DN15 / 20 / 25mm LoRaWAN Smart Water Meter 165 X 85 X 111mm

Brand Name:Radarking
Certification:CE, CCC, ISO9001, ISO14001, ISO4064
Model Number:SKZS
Minimum Order Quantity:100 pcs
Delivery Time:15-20 working days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: No.270, Huangjinkou 3rd Village, Hanyang District, Wuhan City, Hubei Province, China
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

DN15/20/25mm LoRaWAN Smart Water Meter for Cold and Hot Water


Introduction:
The wireless smart water meter consists of remote based water meter, wireless communication modules and other components. This product can complete the data collection of point-to-point through the gateway with low power consumption, long life and two-way data transmission. It
provides reliable protection for the accurate collection of real-time data; Wireless water meter uploads data to the gateway everyday automatically, then the gateway uploads data to the network platform automatically; This product is simple in structure, easy to maintain and replace, and connect with no cables. So, it is easy to install.


Specification:

1. Operating environment:

Water temperature: 0.1℃~30℃

Protection grade: IP68

2. Operation water pressure: 0.03MPa~1.0MPa

3. Pressure loss: ≤0.1MPa

4. Main Parameters:

Power ConsumptionStatic current consumption (wireless module doesn’t include counting sensor)≤10µA
Wireless current receiving power consumption≤18mA
Wireless current emission power consumptionAbout 120mA

Wireless

Performance

Parameter


RF center frequency433MHz
ModulationLORA
Frequency bandwidth125KHz,250KHz can be optional
RF power20dbm(100mW) (Typical)
Transmission rate0.25-50kbps (LoRaWAN)
Receiver sensitivity-143dBm @SF12/BW 125KHz
Power supply3.6V lithium batteryMore than 10 years
Sampling MethodHall sensor, double pulsePointer sampling at 0.01, addend when positive rotation, subtrahend when inverse rotation.

Specifications:

Nominal Size

DN

mm

In-Line
152025
Maximum flow rateQ4m3/h3.1255.07.875
Ratio “R”Q3/Q1808080
Permanent l flow rateQ33

m3/h

2.54.06.3
Transitional flow rateQ220.050.080.126
Minimum flow rateQ110.0310.050.0787
Minimum reading

m3

0.0005
Maximum reading99999

Maximum Permission Error (MPE)
Q1≦Q≦,Q2 MPE =+ 5% Q2≦Q≦Q4, MPE= + 2% (For hot water metering, MPE=+ 3%)


Dimensions and diagram


Nominal sizeLengthWidthHeightThread
mmD
15165101124G3/4B
20195101124G1B
25225101124

G5/4B


Allowable Maximum Error:
From the minimum flow to the low zone that does not include the demarcation flow: ±5%;
From the demarcation flow to the high zone including the overload flow: ±2%. 2.8 Communication Distance: City transmission distance: About 2km
The number of floors crossed: About 15 floors
Power Supply: The gateway needs an external 220V power supply; All prepaid costs are stored in the meter reading system. Based on the collected data of water consumption, it is determined whether the user owes fees.


Communication Introduction:
LoRaWAN is a set of communication protocols and system architectures designed for LoRa long-distance communication networks. When the module is powered on, it automatically sends a join packet. If no reply from the gateway to the network, the join packet will be sent in intervals. After the module receives the network access permission message by the gateway, it pushes a packet of heartbeat data; Since then, it starts timing. Actively push a pack of heartbeat data at intervals of 6 hours. The data upload mechanism can be timed or quantitative or both, and can also be customized on demand.

Device uploads packets

NameDataInstruction
LeadingFEFEFEFE
Frame initiator68H
AddressA5 A4 A3 A2 A1 A0Low byte first when sending
Frame initiator68H
Control code91H
Length0CH
Data identification00004200Low byte first when sending
Data (Note 1)XXXXXXXXLow byte first when sending
Status word (Note 2)XXXXLow byte first when sending
Battery voltageXX15.37×xxH=xxxxxmV
Reserved bytesXX
ChecksumCS
Terminal code16H

Note1: The data format is defined as follows:

Data FormatCode SystemUnitRemarks
Accumulated Water Meter ReadingXXXXXXXXBCDTons

Cumulative water consumption

The decimal place defaults to 2 bits of data. The format is: XXXXXX.XX

Note2: Status word is defined as follows:

ST0D7D6D5D4D3D2D1D0
DefinitionMandatory stateStrong magnetic interferenceOverdraft statusAlarm statusVoltageValve status
InstructionReserved

0:no mandatory

1: Forced

0: normal

1: Overdraft

0: normal

1: Overdraft

0: normal

1: alarm

0: normal

1:Under voltage


00: open

01: Off

11: Abnormal

ST1D7D6D5D4D3D2D1
Definition
InstructionReservedReservedReservedReserved

Assembly:

1.The water meter should be installed in a position where there is clean and dry and no direct sunshine or pollution or drowning.
2.The water meter should be installed horizontally, and the LCD should be upward.
3.Water flow must go with the same direction as indicated on the body of the water meter.
4.When assemble, the valve in front of water meter should be closed.
5.When assemble, the water meter should be covered to prevent from damage.
6.The water meter should be connected to the couplings first, and not directly to the water pipe. Extra parts include couplings and nuts.


Installation and Attentions:
The installation and use of water meters shall comply with the relevant provisions of Chapter 6 of Standard GB/T778.2-2007 and Article 6.3 of JJG162-2009.

1. The water meter to be purchased should be based on the flow rate often used in the pipeline, and it should be close to the usual flow rate of the water meter.

2. Before installing the water meter, foreign matter and contamination in the pipe should be removed.

3. The installation environment should be suitable, anti- freeze, anti-pollution, waterproof, anti-magnetic and prevent mechanical damage. Water meters should be easy to read, install, maintain, and disassemble.

4. The water meter should be installed horizontally. The arrows on the case should point in the same direction as the water flow in the pipe. The pipes connected to both ends of the water meter should be installed on the same axis to prevent the water meter and accessories from being damaged.

5. A stop cock or valve can be installed upstream of the water meter


China DN15 / 20 / 25mm LoRaWAN Smart Water Meter 165 X 85 X 111mm supplier