Home /Access Control Card Reader /

Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell Locker Meter Tracking system

Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell Locker Meter Tracking system

Brand Name:HCB
Certification:UN/CE/UL
Model Number:ER18505M
Minimum Order Quantity:1K pcs
Delivery Time:35 work days
Payment Terms:T/T, L/C
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan Hubei China
Address: No.1 Special Taizhong Avenue, Gaoqiao Industrial Park, Wujiashan Economic Development Zone, Wuhan, Hubei, China
Supplier`s last login times: within 46 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Professional Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell

Nominal Capacity3500mAh
Battery discharged at continuous current 6mA until voltage reaches cut-off voltage 2.0V at ambient temperature 23±2℃
Nominal Voltage3.6 V
Maximum Continuous Current600mA
Battery with minimum 50% rated capacity discharged at ambient temperature 23±2℃
Maximum Pulse Discharge Current1200mA
Battery with minimum 50% rated capacity discharged at max pulse for 3 seconds after 27seconds break. Ambient temperature 23±2℃
Storage Condition

Temperature ≤ 30℃

Humidity ≤ 75%RH

Operating Temperature-55℃ to +85℃
Battery DimensionSee drawing on pag
Max Weight32.0g
Self-discharge Rate2%
Max self-discharged rate at ambient temperature 23±2℃
Shelf Life10 years
Ambient temperature 23±2℃

1. Battery Characteristic


  • High Voltage

The nominal voltage of single cell up to 3.6V, the operating voltage varies with the load, normally between 3.3V and 3.6V

  • High Energy Density

The specific energy density of each battery is 393Wh/kg

  • Wide Operating Temperature Range

The battery with a strong adaptability to temperature can be in work between -55℃ ~ +85℃

  • Stable Operating Voltage

Stable operating voltage, more than 90% of the capacity could be output with a fixed voltage

  • Long Shelf Life

Under the condition of normal temperature, the battery self -discharge rate of no more than 2% per year


Battery sealing using the fully sealed structure to reduce the leakage of the battery, make the battery can be stored at room temperature for more than 10 years


2. Main Applications


  • Infrastructures

Automatic meters (water meter, electric meter, gas meter), conventional meters, etc.

  • Telecommunications

Wireless telecommunication devices

  • Oil & gas

Well pressure meters in high temperature, float meter, logging while drilling (LWD), measure while drilling (MWD), etc.


3. Manufacturing Advantages


  • The technology in HCB is advanced and automatic;
  • Excellent control of passivation;
  • There are variety of solutions such as high power, high capacity or high temperature etc;
  • Combing suggestions and multiple cascade and parallel connecting ways are workable for HCB;
  • There are multiple safety designs for our products.
  • We are very professional in making Li-SOCl2 batteries with more than 20 years experience

4. Company Advantages


  • The quality management system in HCB is accord with GB/T19001-2008/ISO9001:2008 standard;
  • Environment Management System of HCB is conformity with GB/T24001-2004/ISO14001:2004;
  • 1.2 meter drop test can be available to our battery;
  • HCB can provide the report for safe transport of goods to the customers;
  • The CE certificate can be given to you if required;
  • The Rosh certificate can be given to you if required;
  • UL test is available for HCB Battery;

5. FAQS of General Safety Instructions


  • In order to keep the battery safely, what should we do?

The Battery should be stored in dry environment.


  • What kind of case do we need to stop using the battery?

We need to stop using the battery when the abnormal heat release or leakage occurs.


  • Why is there a manual in the master cartons?

The manual is necessary to read before you would like to use the battery.


  • What are you careful with if there are children beside when you use the battery?

You need to keep battery out of the children. Please call to a physician immediately if it is swallowed by children.


  • Why should you keep the batteries away from the fire?

They are going to be hot in very short time and it will lead the leakage of gas and toxic materials which may cause a big rupture.


  • If the positive and negative polarity of a battery is directly connected, what will happen?

If + and - polarity of battery is connected directly, it causes a short circuit and this may lead toxic gas and materials leakage or a big rupture.


  • What will happen if the batteries are thrown into the water?

The batteries are not able to be thrown into the water. This can cause the water explosion.


China Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell Locker Meter Tracking system supplier

Li SOCl2 Lithium Battery 3.6 V , Lithium Thionyl Chloride Cell Locker Meter Tracking system

Inquiry Cart 0