Home /Electronic & Instrument Enclosures /

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

Brand Name:ESTEL
Certification:ISO9001, CE, 3C, FCC, TLC, IP55
Model Number:DDTE016
Minimum Order Quantity:1
Delivery Time:10-15 working days
Payment Terms:L/C,D/A,T/T, Western Union, Paypal, etc
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Shenzhen, China
Supplier`s last login times: within 35 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System


Quick Details


Place of Origin: Shenzhen, China (Mainland)External Size H×W×D 2100×1600×800mm
Brand Name: ESTELStructure: sandwich structure, double wall, with insulation .
Model Number: DDTE016Cabinet Layout: two compartments
Product Name: base station cabinetCabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55Protection Level: IP55
Application: outdoor telecom base stationCable Entry: at cabinet bottom
Material: galvanized steelIllumination: DC48V LED lamp
Heat Insulation: PEFGrounding Protection: copper bar
Color: grey (support custom made)Cooling: peltier air conditioner and heat exchanger
Coating: anti-corrosion outdoor powder coatingAccessories Options: PDU, rectifier system, environment monitoring system

Payment & Shipping Terms


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:L/C,D/A,T/T, Western Union, Paypal, etc
Supply Ability:6,000 sets per month
Delivery Time:10-15 working days
Packaging Details:wooden case

1. Specifications

(1) Technical Parameters


ItemTypeTechnical Parameter
StructureDimensionExternal Size H×W×D 2100×1600×800mm
LayoutTwo compartments
Equipment Installation Method19” standard rack
DoorWith two front doors, and anti-theft three point lock for outdoor cabinet (support padlock)
Material

1.Galvanized steel;

2.Double walls, thickness of outer plate: 1.5mm, thickness of inner plate: 0.8mm, with 20mm heat insulation between two walls.

StructureAssembled
Ingress ProtectionIP55
Temperature ControlCoolingpeltier air conditioner and heat exchanger
LightingLED lamp48V LED lamp
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1124 × (1±5%)W/m2

Accessories List


No.ItemQuantityUnitSpecs
1Two Compartments Outdoor Telecom Cabinet1SetExternal Dimension: H×W×D 2000×1600×800mm
2Peltier Air Conditioner1Set

Cooling Capacity: 200W

Power Supply: DC48V

3Heat Exchanger1Set

Heat Exchange Capacity: 80W/K

Power Supply: DC48V

4Rectifier System1SetDC48V, 120A
5Power Distribution Unit1Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4.

Height: 4U

6Environment Monitoring Unit1Set
7Temperature and Humidity Sensor2PC
8Door Sensor4PCTwo for controlling LED lamp on/off, the other two for door open alarm
9Water Sensor2PC
10Smoke Sensor2PC
11LED Lamp2PCDC48V
12Package1SetWooden Case

2. Description


The DDTE016 Outdoor Integrated Telecom Enclosure is mainly used in wireless communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.

The cabinet, made of galvanized steel, is divided into equipment compartment and battery compartment. The right part of the cabinet is equipment compartment, which is separated from the battery compartment for heat insulation of the equipment space. The battery compartment is used for installing batteries. The cabinet body has heat insulation foam, which can keep the temperature inside the cabinet. The cabinet also has roofs which is sun proof and water proof. There’re ventilations for releasing harmful gas generated by the batteries.

The cabinet door uses embedded structure. The door opening angle is larger than 110°and the door limit device can limit the opening angle. The lock is theftproof three point lock. There’s open door alarm sensor, which works together with the environment monitoring unit.


3. Features


  • The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment. The protection level is IP55.
  • Three cooling for the cabinet: heat exchanger ,air conditioner and fans-.
  • -48V lamp is installed inside the cabinet.
  • The cabinet is installed with Environment Monitoring Unit, door alarm, temperature and humidity sensor, smoke sensor, water sensor etc., which can work together to monitor the inside environment of the cabinet.
  • The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There’re entrance holes individually for power cable, signal cable and optical cable.
  • All the cables used in the cabinet are made from flame retardant materials.

4. Cabinet Structure

4.1 Door and Door Limit


(1) Cabinet door options: vertical hinge door, horizontal hinge door.

(2) The door limit device can limit the door position when it is open.

(3) The door limit function is automatically activated when the door is open, and should be canceled manually when the door is closed



When the door is fully opened, the largest open angle is larger than 95°. If it is horizontal hinge door, it can prevent outside water from flowing into the equipment compartment from the upper side. The bottom edge of the door limit device is higher than the hinge level, which can offer enough operating space.


(5) After 1000 times open and close operation, the door and door device will have good function and have no excessive wear and tear.

(6) At the door limit status, the door limit device can bear the static load by door opening and closing at 22m/s wind, without mechanical failure and function failure.


4.2 Grounding


The cabinet include grounding copper bar, 4mm thick, with 10×M6 flare-in nuts, 2×M8 flare-in nuts, 2×M10 flare-in nuts. The grounding bar is nickel plated. The screw is made from copper bar and with passivation surface treatment.



4.3 Theft Proof Design

  • Theft proof lock


  • Three point lock


4.4 Cable Entry


Feeder cable and other external cables all use bottom wiring method.



4.5 Appearance and Surface Treatment


Outdoor powder coat, with gray color. The coat is anti-shock, anti-aging, anti-solvent, anti-low temperature.


5. Electrical Technical Parameters

5.1 Monitoring System Diagram and Solution


Monitoring alarm


The monitoring unit conducts real time monitoring on smoke, water, door opening, LED lamp, temperature and humidity inside each compartment through various sensors. It is with alarm output, and can transmit alarm signals to Local Area Network or remote monitoring platform through RS485/RS232, Ethernet etc.


Monitoring Unit Diagram



The monitoring unit uses dual core processing. the power supply uses DC/DC module. The measuring channel, power supply, and communication interfaces are electrically isolated, so the monitoring unit has high reliability . The MCU control design has functions of self management and self correction. The monitoring unit support RS485/RS232 communication method. With the communication interfaces, it can realize many kinds of communication modes, such as point to point communication, point to multipoint communication, wireless remote communication, which can meet the need of various system networks.


5.2 Monitoring and Alarm


The monitoring unit conducts the following monitoring and alarm for the cabinet: door alarm, power failure alarm, smoke alarm, water alarm, temperature and humidity detection and alarm, shock and tilt alarm, etc.


Door alarm


There are two door switches. The one near the top of the cabinet is used for control the on/off of LED lamp, and the other one detects the opening and closing of the cabinet door. When the door is open, the door switch closes, and the monitoring unit will transmit the alarm to the control center through RS485/RS232. Meanwhile, there is correlative alarm dry contact output (port AL6, AL7). It will close in abnormal situation.


Power failure alarm


The port “AC220V” on the monitoring unit is for utility power detecting input. In case of utility power failure, the monitoring unit will transmit the alarm signal to the control center through RS485/RS232, and there is correlative alarm dry contact output (port AL8, AL9). It will close in abnormal situation.


Smoke alarm


The port “S” on the monitoring unit is for smoke sensor detecting input. When smoke is detected, the red light on the smoke sensor turn bright, the monitoring unit will transmit the alarm to the control center, and there is correlative alarm dry contact output (port AL2, AL3). It will close in abnormal situation.


Water alarm


The port “w+. w-” on the monitoring unit is for water sensor detecting input. When water is detected inside the cabinet, the monitoring unit will transmit the alarm to the control center, and there is correlative alarm dry contact output (port AL4, AL5). It will close in abnormal situation.


Temperature and humidity detection and alarm


The port “5V, T1, H1, GND” on the monitoring unit is for temperature and humidity sensor of battery compartment detecting input, and port “5V, T2(or T3), H2(or H3), GND” is for temperature and humidity sensor of equipment compartment detecting input. The monitoring unit can conduct real time detecting on temperature and humidity inside the compartment. When temperature and humidity sensor send out alarm signal, the monitoring unit will transmit the alarm signal to the control center, and there is correlative alarm dry contact output (port AL0, AL1). It will close in abnormal situation.


5.3 Technical Parameters of Monitoring Unit and Sensors

Environment Monitoring Unit


  • 19”, 1U, power supply DC48V/AC220V
  • Communication mode: RS232/RS485
  • 8 analog inputs. 4 specially for temperature and humidity detecting, the other 4 for general analog detecting, universal input.
  • 13 switch DI inputs, the port function can be redefined through programing.
  • 14 switch DO outputs, the port function can be redefined through programing.
  • LCD display, user friendly


Door Alarm


(1) Technical Parameters:

Contact power: ≤10W

Voltage: ≤28VDC

Current: ≤0.5A

Contact impedance: ≤300mΩ

Action distance: 35mm

Fixing mode: embedded

Safety standard(UL):94-HB


Function:

When forcible entry (forcible opening the cabinet door) happens, the door sensor will send the door alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



Power Failure Alarm


Technical Parameters:

Coil voltage: AC220V

Power: ≤0.1W


Working temperature: -20°C ~ 70°C

Working humidity: 0% ~ 95%

Communication mode: contact output


(2) Function:

When AC power supply failure happens, the sensor will send AC power supply failure alarm signal, and transmit the alarm signal to the monitoring center in switching mode.


Smoke Sensor


Technical Parameters:

Voltage: 5-24 VDC

Power: ≤1W

Working temperature: -20°C ~ 70°C

Working humidity: 0% ~ 95%

Communication mode: contact output


Function:

When burning or smoke happens inside the cabinet, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



Water Sensor


(1) Technical Parameters:

Voltage: 5-15 VDC

Power: ≤0.5W

Alarming water level: 5mm

Working temperature: -20°C ~ 70°C

Working humidity: 0% ~ 95%

Communication mode: contact output


Function:

When water level inside the cabinet reach the alarming level, the sensor will send out alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



Temperature Sensor


(1) Technical Parameters:

Voltage: +5VDC

Power: <0.5W

Temperature error: ±0.2°C

Temperature resolution: 0.0625°C

Working temperature: -50°C ~ 120°C

Working humidity: 0% ~ 95%

Communication mode: monobus


(2) Function:

When temperature inside the cabinet exceed the set range, the sensor will send out high temperature or low temperature alarm signal, and transmit the alarm signal to the monitoring center in switching mode.



Temperature Control Failure Alarm


(1) Technical Parameters:

Voltage: +5VDC

Power: <0.5W

Temperature error: ±0.5°C

Temperature resolution: 0.0625°C

Working temperature: -50°C ~ 120°C

Working humidity: 0% ~ 95%

Communication mode: monobus


(2) Function:

When temperature control device fails, the sensor will send out temperature control device failure alarm signal, and transmit the alarm signal to the monitoring center in switching mode.


6. Protection


The cabinet is corrosion proof, water proof, dust proof, condensation proof, wind proof, lightening proof. The protection level is IP55.


7. Lighting and other specs


(1) The working voltage of the lamp is -48VDC or 220VAC.

(2) LED lamp can turn on or turn off intelligently. When the cabinet door is open, the LED will turn on automatically. When the cabinet door is closed, the LED will turn off automatically.

Displacement sensor for detecting cabinet door. When the door is open, it pops up and at close circuit situation.



(3) The cabinet includes 220V power socket.

(4) The MDF compartment and equipment compartment have document holders.

(5) The service life of the cabinet sealing strip is longer than 10 years, and is easy for replacement.


8. Packing and Shipping



Our Delivery Agent


The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.


9. Our Contact Information


Mobile Phone: 0086-13752765943

Telephone: 0086-0755 66600941

Email: info@estel.com.cn

lxf.estel@hotmail.com
Skype: fiona.liang10

China Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System supplier

Dustproof Two Compartments Base Station Cabinet Outdoor With Cooling System

Inquiry Cart 0