Product Details

19 Inch Air Conditioner Type Outdoor Telecom Cabinet With Three Point Anti-theft Lock, Outdoor Equipment Enclosure


Quick Details:


Place of Origin: Shenzhen, China (Mainland)

External Dimension: W×D×H 900×900×2100mm

Internal Dimension: W×D×H 800×800×1800mm

Brand Name: ESTELStructure: double wall, with insulation, sandwich structure
Model: ET9090210-EQCabinet Layout: one compartment, for installing 19” power equipment
Product Name: Outdoor Telecom Equipment CabinetCabinet Lock: anti-theft three point lock
Certification: ISO9001, CE, 3C, FCC, TLC, IP55Protection Level: IP55
Application: outdoor telecom base stationCable Entry: at cabinet bottom
Material: galvanized steelIllumination: DC48V LED lamp
Heat Insulation: PEFGrounding Protection: copper bar
Color: grey (support custom made)Cooling Method: AC220V air conditioner and DC48V fans
Coating: anti-corrosion outdoor powder coatingAccessories Options: PDU, rectifier system, environment monitoring system

Payment & Shipping Terms:


Minimum Order Quantity:1 set
Price:negotiation
Payment Terms:T/T, L/C, DA, DP, etc
Supply Ability:8,000 sets per month
Delivery Time:15-20 working days
Packaging Details:wooden case

1. Specifications

(1) Technical Parameters


ItemTypeTechnical Parameter
StructureDimension

External Dimension: W×D×H 900×900×2100mm

Internal Dimension: W×D×H 800×800×1800mm

Layout1 compartment
Equipment Installation Method19” rack
DoorWith one front door, and anti-theft three point lock for outdoor cabinet (support padlock)
MaterialGalvanized steel, double wall, 1.5mm thick outer plate, 0.8mm thick inner plate
Heat InsulationThere are heat insulation between inner wall and outer wall. The insulation material is 20mm PEF
Ingress ProtectionIP55
Temperature ControlCoolingAC220V air conditioner and DC48V fans
Lightning ProofGrade B lightning proofNominal: 60KA, Max.: 100KA
LightingLED lamp48V LED lamps (immovable), with protective circuit breaker
TemperatureTemperatureWorking Temperature: -40°C ~ +55°C
Storage Temperature: -50°C ~ + 70°C
Transport Temperature: -50°C ~ +70°C
HumidityRelative Humidity5% ~ 100%
PressureAir Pressure62kpa ~ 101kpa (similar to 0m ~ 5000m altitude)
Radiation IntensitySolar Radiation Intensity1120 ×(1±5%)W/m2

Accessories List


No.ItemQuantityUnitSpecs
1Outdoor Telecom Cabinet1Set

(1) External Dimension:W×D×H 900×900×2100mm

Internal Dimension: W×D×H

800×800×1800mm

(2) One compartment: equipment compartment

(3)With one front door, and anti-theft three point lock for outdoor cabinet (support padlock)

(4) Material: galvanized steel; 1.5mm thick outer plate, 0.8mm thick inner plate; with 20mm PEF heat insulation between two walls.

2Air Conditioner1Set

Cooling capacity: 1.5KW,

Power supply: AC220V, 50HZ,

Model:TC06-150JFH/01

3Auxiliary Direct Ventilation Fans1PC12038 DC48V
4Environment Monitoring Unit1Set1U, Model: SM2400
5Water Sensor1PC
6Smoke Sensor1PC
7Temperature and Humidity Sensor1PC
8Door Sensor2PCOne for controlling LED lamp, the other for open door alarm
9LED Lamp1PCDC48V
10Power Distribution Unit1Set

Grade B Lightning Proof

AC Input: 63A/2P *1;

AC Output: 16A/1P*4;

DC Output: 16A/1P*4

Input Voltage: AC220V.

11Rectifier System1Set

Model: GPE48120C (DC48V, 120A)

Including:

(1) 4×30A Rectifier Module;

(2) 1× Monitoring Module;

(3) Power distribution frame.

12Package1SetWooden Case

2. Features


  • The cabinet is dustproof, sunproof and rainproof, which is used in outdoor environment.
  • Cabinet cooling: air conditioner and fans. MTBF≥50000h.
  • The layout of the cabinet is reasonable, which will facilitate cable access, fixing and grounding. There are entrance holes individually for power cable, signal cable and optical cable.
  • All the cables used in the cabinet are made from flame retardant materials.
  • The cabinet includes grounding bar.
  • Surface treatment: degreasing, derusting, rustproof phosphating (or galvanizing), powder coated.
  • Cabinet load bearing: ≥600kg
  • Ingress protection: IP55
  • Flame retardance: comply with GB5169.7 test A
  • Insulation resistance: the insulation resistance between grounding devices and cabinet body parts is not lower than 2×104M/500V(DC).
  • Withstand voltage: the withstand voltage between grounding devices and cabinet body parts is not lower than 3000V(DC)/1min.
  • Mechanical strength: each surface can bear upright pressure >980N; after the door is open, its outer end can bear upright pressure >200N.

3. Applications


The ET9090210-EQ Outdoor Telecom Cabinet is mainly used in wireless communication base station, such as 4G system, communication/network integrated service, access/transmission switching station, emergency communication/transmission, etc.


4. Dimension Diagram


5. Components Installation


5.1 LED lamp, smoke sensor and door sensor are installed at the top of the cabinet. Environment monitoring unit, rectifier system and PDU are installed on 19” rack.

5.2 Water sensor is installed at the bottom of the cabinet.

5.3 Temperature and humidity sensor is installed at the side inside the cabinet.

5.4 Air Conditioner is installed on the door of the cabinet.

6. Cable Inlet


Feeder cable and other external cables all use bottom wiring method.


7. Grounding Protection


  • The cabinet includes grounding copper bar with anti-corrosion coating. There are enough screws for wiring connection terminals.
  • The metal part of the cabinet should be interconnected and be connected with grounding bar. Connection resistance between any two points is lower than 0.1Ω.
  • Protective earthing of other equipments inside the cabinet should be connected to the grounding bar.

8. Theft Proof Design

8.1 Door lock theft proof design


Damage resistance of the theft proof lock meets GA/T 73-1994 “Mechanical Anti-theft Lock” class B requirement, supporting padlock.


Three point lock

8.2 Connection and Fastening


  • Use anti-loose threaded connection as structure and bearer connection. Anchor bolt for fixing cabinet use hot dip galvanized bolts.
  • Door hinges use inner hinge mode.

8.3 Appearance and Surface Treatment


Cabinet surface coating is outdoor special powder coating, with white gray color (PANTONE 428C). The coating complies with GB/T 3181-2008 requirement.


9. Packing and Shipping



Our Delivery Agent


The goods can be shipped by sea, by air, by courier, by land, by train, etc.

Besides the following delivery agent, we can also look for the delivery agent with the best price in china if you need us to do for you.



10. Our Partner

China 19 Inch Outdoor Equipment Enclosure 42U Communication cabinet supplier

19 Inch Outdoor Equipment Enclosure 42U Communication cabinet

Inquiry Cart 0