Add to Cart
2HP Household Air source heat pump 7KW stainless stell shell heating house provide hot water
Technology Specification
Feature:
1. Economical operation
Generally cost less to operate than other types of conventional heating systems, save your electricity or gas bills.
2. Safety
Operate at a high efficiency with no flames, fumes, or flues; Water and electricity isolated
3. Environmental friendly
Transfer heat that’s already in the environment; Low CO2 emissions.
4. Easy operation
With intelligent control systems which convenient and simple operation
5. Constant hot water supply
Provide hot water no matter in cloudy day, snowy day or at night, unlike solar collectors which have to be facing the sun.
6. Wide application
7. Heat pump water heater can be applied to sanitary hot water, house heating .
Internal porduct accessories
1 compressor
The world-famous Copeland Flexible Scroll Compressor has functions
such as low wear resistance, long service life, over-current
protection, phase loss protection, over-the-counter protection,
strong liquid-impact resistance, and high and low voltage
protection. Copeland compressor built-in pressure relief valve in
the body can automatically relieve pressure when the high pressure
is too high
2 Electronic expansion valve
The introduction of the latest Japanese technology in conjunction
with the company's control system has led to the development of a
unique electronic expansion valve control method and the use of
digital technology control to control the working fluid to achieve
the best flow velocity effect, thereby increasing the COP value.
3 Condenstion heat exchanger
In combination with the United States and the United States outside the threaded pipe technology, successfully created a "spring" spiral tube new structure condenser. Better heat transfer, faster heat transfer, and higher efficiency, minimize fouling, extend heat pump life and reduce maintenance
4 Electronic control system With powerful engineering supporting control functions , it can control circulating water pump, make-up water , return water, water supply , electric heating , PID automatic defrosting, etc., making the control easier. According to the needs of different projects, it can set various parameters by itself and realize various water supply schemes . The entire system can be automated without special care.
5 Evaporation heat exchanger
The use of hydrophilic membrane aluminum foil, even after long-term
use
The use of a hydrophilic layer also does not result in oxidative
detachment. this
The evaporator has a special advantage: Excellent skis performance
The more you can reduce the wind resistance, so that the condensate
drains out quickly
outer. Internally-threaded copper tube and corrugated aluminum foil
structure
High evaporator efficiency.
Payment service
1. T/T
2. L/C (for container order only)
After selling
1. We promise to offer free consulting call in 7~24 hours mode to
solve the problems found in practice.
2. Products guarantee is 18~24 months from ex-factory date. Within
18months,if any components of your products damaged because of
quality, we supply new replacement for free.
3. After the expiration of the quality assurance, we will continue
to provide lifelong maintenance services, with just charging some
cost price.
FAQ
Why us?
1. Timely Delivery, considerate sales after service
2. Many Years quality warranty,OEM service.
3. Top Craftmanship, All products 100% tested
4. Preferential freight by Famous shipping company
5. New Design,Very popular style products recommendation for your local market
Packaging & Shipment
1> Meeting heat pump can sure delivery heat pump within 5~20 working days as we warehouse stock condition.
2> Heat pump with strong plywood pallet , strong plywood box for loading, make sure no problem happen during rude transporattion .
3> All spare parts of the heat pump water heater will together loading into package , one time finished shipment to buyer.
4> Take video of the heat pump for buyer before package to 100% sure buyer get product same as order, no any different.
5> Meeting heat pump offer 100% test online, 5% test in Lab by 24 hour for one lot order (if not new model)
Packaging Details :Standard export packing -with plywoods case packages,OEM is available for Factory price heat pump water heaters
Delivery Time :15 work days after arrival of down payment
MODEL | Unit | MD10D | |
Rated heating capacity | KW | 3.5 | |
Rated Cooling capacity | 1.8 | ||
Hot water supply | L/h | 75 | |
Average heating input power | KW | 0.75 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 29 | |
MODEL | Unit | MD15D | |
Rated heating capacity | KW | 5 | |
Rated Cooling capacity | 3 | ||
Hot water supply | L/h | 100 | |
Average heating input power | KW | 1.25 | |
Rated heating input current | A | 6 | |
Rate outlet water temp | ℃ | 55 | |
COP | 3.65 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 48 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 1600L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 40 | |
MODEL | Unit | MD20D | |
Rated heating capacity | KW | 7 | |
Rated Cooling capacity | 5 | ||
Hot water supply | L/h | 150 | |
Average heating input power | KW | 1.84 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 3.8 | ||
Power | V/Hz | 220V/50 | |
Noise | Db(a) | 50 | |
Dimension | W*D*H | mm | 1140×360×540 |
Packing size | W*D*H | mm | 1200*400*710 |
Unit weight | KG | 75 | |
Refrigerant | R417A//R410 | ||
Working air temp range | ℃ | (-20℃)—45℃ | |
compressor | Type | Panasonic | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 2000L/h | |
Water pressure down | Kpa | 30 | |
Pipe size | DN | 20 | |
Max flat square meter | M2 | 55 | |
MODEL | Unit | MD30D | |
Rated heating capacity | KW | 12 | |
Rated Cooling capacity | 7 | ||
Hot water supply | L/h | 260 | |
Average heating input power | KW | 3 | |
Rated heating input current | A | 13/6 | |
Max outlet water temp | ℃ | 60 | |
COP | 4 | ||
Power | V/Hz | 220V/380/50 | |
Noise | Db(a) | 54 | |
Dimension | W*D*H | mm | 1120*490*710mm |
Packing size | W*D*H | mm | 1190*520*865mm |
Unit weight | KG | 108 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 3000L/h | |
Water pressure down | Kpa | 40 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 100 | |
MODEL | Unit | MD40D | |
Rated heating capacity | KW | 16 | |
Rated Cooling capacity | 10 | ||
Hot water supply | L/h | 360 | |
Average heating input power | KW | 4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 4000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 125 | |
MODEL | Unit | MD50D | |
Rated heating capacity | KW | 18 | |
Rated Cooling capacity | 12 | ||
Hot water supply | L/h | 400 | |
Average heating input power | KW | 4.4 | |
Rated heating input current | A | 9 | |
Max outlet water temp | C | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 55 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 160 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 5000L/h | |
Water pressure down | Kpa | 45 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 150 | |
MODEL | Unit | MD60D | |
Rated heating capacity | KW | 21 | |
Rated Cooling capacity | 15 | ||
Hot water supply | L/h | 520 | |
Average heating input power | KW | 5.68 | |
Rated heating input current | A | 12 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1120*490*1270 |
Packing size | W*D*H | mm | 1200*520*1425 |
Unit weight | KG | 210 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 6000 | |
Water pressure down | Kpa | 48 | |
Pipe size | DN | 25 | |
Max flat square meter | M2 | 175 | |
MODEL | Unit | MD100D | |
Rated heating capacity | KW | 36 | |
Rated Cooling capacity | 24 | ||
Hot water supply | L/h | 800 | |
Average heating input power | KW | 9.2 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 289 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 10000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 300 | |
MODEL | Unit | MD150D | |
Rated heating capacity | KW | 42 | |
Rated Cooling capacity | 29 | ||
Hot water supply | L/h | 1200 | |
Average heating input power | KW | 11 | |
Rated heating input current | A | 18 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.2 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 60 | |
Dimension | W*D*H | mm | 1450×760×1060 |
Packing size | W*D*H | mm | 1520*800*1230 |
Unit weight | KG | 320 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 15000L/h | |
Water pressure down | Kpa | 54 | |
Pipe size | DN | 32 | |
Max flat square meter | M2 | 350 | |
MODEL | Unit | MD200D | |
Rated heating capacity | KW | 72 | |
Rated Cooling capacity | 48 | ||
Hot water supply | L/h | 1590 | |
Average heating input power | KW | 18.2 | |
Rated heating input current | A | 35 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 65 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C/R404A | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 20000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 600 | |
MODEL | Unit | MD300D | |
Rated heating capacity | KW | 88 | |
Rated Cooling capacity | 65 | ||
Hot water supply | L/h | 24000 | |
Average heating input power | KW | 25 | |
Rated heating input current | A | 45 | |
Max outlet water temp | ℃ | 60 | |
COP | 4.5 | ||
Power | V/Hz | 380V/50 | |
Noise | Db(a) | 68 | |
Dimension | W*D*H | mm | 2040×1100×2000 |
Packing size | W*D*H | mm | 2080×1150×2130 |
Unit weight | KG | 650 | |
Refrigerant | R417A/R407C | ||
Working air temp range | (-20℃)—45℃ | ||
compressor | Type | Copeland | |
Air source heat exchanger | Type | Finned heat exchange | |
Fan Type | axial flow fan | ||
Hot water side heat exchange | Type | Coil heat exchanger | |
Water flow | L/H | 30000L/h | |
Water pressure down | Kpa | 60 | |
Pipe size | DN | 50 | |
Max flat square meter | M2 | 730 |
ABOUT US
1). We were established in 2001.
2). We are a professional heat pump manufacturer, Located around Baiyun Air port
3). We are trading on Meeting Brand ,Meeting heat pump Well-know brand we operate in Europe market
4). Our company has been inspected and certificated by TUV and SGS.
5). We are the one of the first manufacturers whose heat pumps are with top COP gaining grants from Chinese government.
6). We passed ISO 9001 quality management system and ISO14000 environment protection system
7). Our testing laboratory can test heat pump up to 60KW heating capacity and create testing air temperature condition during -25DegC~45DegC,according to EN14511 standard.
9). Our leading products: Air to water heat pump , DC inverter heat pump, High water temperature heat pumps