China Categories
English
Home /General Assay & Diagnostic Apparatuses /

Blood Count Machineblood Glucose Level Testing Kit Capillary / Venous / Arterial / Blood Types

Blood Count Machineblood Glucose Level Testing Kit Capillary / Venous / Arterial / Blood Types

Brand Name:sinocare
Certification:CE
Model Number:safe AQ voice
Minimum Order Quantity:3000
Delivery Time:30 working days
Place of Origin:China
Contact Now

Add to Cart

Active Member
Location: Changsha Hunan China
Address: No.265 Guyuan Road Hi-tech Zone,Changsha,Hunan,China,410205
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Blood Count Machineblood Glucose


Level Testing Kit Capillary / Venous /


Arterial / Blood Types


SAFE-AQ VOICE

BLOOD GLUCOSE MONITORIG SYSTEM

SPECIFICATION

FAD-GDH System

Blood sample:fresh capillary whole blood, venous whole blood

Calibration sample:venous plasma

Test range:20-600mg/dL(1.1-33.3mmol/L)

Test time:5s

Blood volume:0.6ul

HCT:30-60%

Expiry date:24 months

Memory:10 test results

Battery lifetime:above 1000 times


First step: prepare the components you will use


1Batteries
2Glucometer
3Strip vial
4Lancing device
5Lancets

Wash your hands, rinse and dry completely.


Screw off the cap of the lancing device. Insert a lancet into the lancet holder and push down until is fully seated. Note that the lancet is for one-time use only

Twist off the protective cap until it separates from the lancets.

Replace the lancing device cap and set the puncture depth to the desired number.


Pull back the cocking control until it makes a click, and then release. Now the lancing device is ready to use.


Remove a new test strip within the valid expiration from vial. After taking the strip, immediately cover the vial. To avoid losing efficiency. Insert test strip into the strip slot, the test strip is suggested to use up within 3 minutes. The meter turns on automatically. When the blood symbol starts blinking, the meter is ready to use.


Use a 75% cotton ball with alcohol at the blood sample site for disinfection, be careful not to use iodine or disinfectant containing "iodine" disinfectant. Once the alcohol has evaporated cleanly, align the prepared puncture device with the disinfected skin and press the button to collect the blood. Use your thumb to resist the lower part of the puncture device to help the blood draw ..


To obtain best accurate results, wipe off the first drop of blood and squeeze another.Apply the blood sample to the opening of the absorbent channel of the test strip until the confirmation window is fully covered with blood. The meter will display your blood glucose value after several seconds.


Push strip ejector to eject the tested strip automatically, twist off the lancets, cover its cap and place it properly according to Medical Waste Management Regulations.



In October of 2015, Sinocare acquired the world's sixth BGM enterprise - Nipro diagnostic Inc. (now renamed as Trividia Health Inc.), reached the international leading BGM corporation, it is now a step closer to “the globle BGM expert”. In the near future, Sinocare will strive to continue to improve products and services, and improve the quality of life of patients with diabetes in the world.

China Blood Count Machineblood Glucose Level Testing Kit Capillary / Venous / Arterial / Blood Types supplier

Blood Count Machineblood Glucose Level Testing Kit Capillary / Venous / Arterial / Blood Types

Inquiry Cart 0