Brand Name:United electrical
Certification:ISO9001, ISO14001, OHSAS18001
Model Number:HZCJ-4800kV/20kJ
Minimum Order Quantity:1 set
Delivery Time:30 working days
Place of Origin:Wuhan, China
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: No.48, K Area, Jiahai Industry Park,Panlong Economic Dveloment Zone,Wuhan City,China 430300
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

HV Lightning Impulse Voltage Generator AC Hipot Test System 300kV/20kJ


Product Description:


HZCJ-4800kV/20kJ impulse voltage generator is used for impulse voltage test of lightning impulse voltage full wave , lightning impulse voltage chopped wave and operation impulse voltage wave which apply to electrical equipment ect. Multiple waveform impulse voltage generator can produce eight kinds of waveforms of standard lightning wave, operation wave, lightning chopped wave, oscillating lightning wave, oscillating operation wave, line insulator steep wave, composite insulator steep wave, transformer induction operation wave. The technology index accords with national standard and IEC standard, is in the leading position at home and has reached an advanced level in the world.

Product Features:


1. Use constant current charging technology, high automation, strong anti-interference performance.

2. Use digital measurement and analysis system and computer on line processing system for impulse test data, greatly improve the test technology and efficiency.

3. Complete sets, full voltage classes.

4. Simple operation, excellent synchronization performance, reliable action.

5. Small loop inductance, take the band elimination filter measures, still produce standard impulse wave in the large-capacity load , large load capacity, high voltage utilization, convenient to adjust wave.


Product Parameters:


Standard VoltageImpulse Capacitance(µF)Classes Capacitance(µF)Impulse Energy(kJ)Classes Voltage(kV)ClassWeight(kg)
±300~±9000.133~0.1110.4~16~45±1003~9547~1378
±1000~±16000.05~0.09370.5~1.525~12010~161366~1880
±1800~±24000.056~0.08330.5~190~240±2009~127353~11574
±2800~±32000.0357~0.06250.5~1.5140~32014~1610266~15680
±3600~±48000.0278~0.031250.5~280~24018~2415480~23500
Technique Parameters
Items1,1.2/50µs 2,250/2500µs 3,2~5µs etc waveforms
Output Peak Value100~10000kV
T1 Wave Front Time1.2µs±30%
T2 Wave Tail Time50µs±20%
Reverse Overshoot<20%
Voltage PolarityPositive/negative(manual shifting)
Waveform ShiftAuto shifting
Charging Time10s~999s, set arbitrarily
Instability of charging voltage<1%
External Input50Hz/60Hz
Trigger MethodAuto or manual, can single trigger
Trigger Maloperation rate<1%
Trigger Range100% rated charging voltage
Display Screen17 inch TFT colour screen
Measurement Display PrecisionBetter than 3%
Tested Product Residual Voltage<5kV
Voltage MeasurementUse damped impulse divider
OscilloscopeTBS series, optional
Insulation Strength≤500V RMS(common to ground refer PE)
General Parameters
Power SourceAC220V±10%, 50/60Hz
Environment Temperature-10±40ºC
Relative Humidity35%-85%RH(no condensation)
Ground Resistance≤0.5Ω
Structure TypeOpen structure,independent control cabinet and main body, optical fiber connection
Control Console1.8M(length)*1.2M(height)*1M(width)
No conductive dust, no fire and explosion hazards, no corrosive metal and insulation gas, waveform
of power voltage is sine wave, distortion <5%.
Equipment model selection parameters
Nominal Total Voltage kVClassImpulse Capacitance (μF)Impulse Level Capacitance(μF)Total Charging Power(kJ)Application
±300~±9003~90.133~0.1110.4~16~4535~110kV
±1000~±160010~160.05~0.09370.5~1.525~120<220kV
±1800~±24009~120.056~0.08330.5~190~240220kV~500kV
±2800~±320014~160.0357~0.06250.5~1.5140~320
±3600~±480018~240.0278~0.031250.5~280~240
Minimum time difference between pulse30s40s
Generator capacity per level≤1600kV use 100kV single side charging 1≥1600kV use 100kV double sides charging