China Categories
English
Home /General Assay & Diagnostic Apparatuses /

Sheep Testosterone Accurate Quantitative Detection Enzyme Linked Immunosorbent Assay Kit

Sheep Testosterone Accurate Quantitative Detection Enzyme Linked Immunosorbent Assay Kit

Brand Name:BT Lab
Certification:CE, ISO9001:2005, MSDS
Model Number:Cat.No E0013Sh
Minimum Order Quantity:1 kit
Delivery Time:1-3 business days, bulk order within one week
Payment Terms:Western Union, T/T
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: #1008.Junjiang Internatioanl Bldg. 228 Ningguo Rd. Yangpu Dist. Shanghai. 200090. China
Supplier`s last login times: within 34 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

High Sensitive Sheep Testosterone ELISA Kit 96 wells


Cat.No E0013Sh

Standard Curve Range: 1ng/ml - 400ng/ml

Sensitivity: 0.52ng/ml

Size: 96 wells

Storage: Store the reagents at 2-8°C. For over 6-month storage refer to the expiration date keep it at -20°C. Avoid repeated thaw cycles. If individual reagents are opened it is recommended that the kit be used within 1 month.

* This product is for research use only, not for use in diagnosis procedures. It’s highly recommend to read this instruction entirely before use.


Intended Use

This sandwich kit is for the accurate quantitative detection of Sheep Testosterone (also known as T) in serum, plasma, cell culture supernates, cell lysates, tissue homogenates.


Assay Principle

This kit is an Enzyme-Linked Immunosorbent Assay (ELISA). The plate has been pre-coated with Sheep T antibody. T present in the sample is added and binds to antibodies coated on the wells. And then biotinylated Sheep T Antibody is added and binds to T in the sample. Then Streptavidin-HRP is added and binds to the Biotinylated T antibody. After incubation unbound Streptavidin-HRP is washed away during a washing step. Substrate solution is then added and color develops in proportion to the amount of Sheep T. The reaction is terminated by addition of acidic stop solution and absorbance is measured at 450 nm.


Reagent Provided

ComponentsQuantity
Standard Solution (480ng/ml)0.5ml x1
Pre-coated ELISA Plate12 * 8 well strips x1
Standard Diluent3ml x1
Streptavidin-HRP6ml x1
Stop Solution6ml x1
Substrate Solution A6ml x1
Substrate Solution B6ml x1
Wash Buffer Concentrate (30x)20ml x1
Biotinylated Sheep T Antibody1ml x1
User Instruction1
Plate Sealer2 pics
Zipper bag1 pic

Wash Buffer Dilute 20ml of Wash Buffer Concentrate 30x into deionized or distilled water to yield 500 ml of 1x Wash Buffer. If crystals have formed in the concentrate, mix gently until the crystals have completely dissolved.


Assay Procedure

1. Prepare all reagents, standard solutions and samples as instructed. Bring all reagents to room temperature before use. The assay is performed at room temperature.

2. Determine the number of strips required for the assay. Insert the strips in the frames for use. The unused strips should be stored at 2-8°C.

3. Add 50μl standard to standard well. Note: Don’t add antibody to standard well because the standard solution contains biotinylated antibody.

4. Add 40μl sample to sample wells and then add 10μl anti-T antibody to sample wells, then add 50μl streptavidin-HRP to sample wells and standard wells (Not blank control well). Mix well. Cover the plate with a sealer. Incubate 60 minutes at 37°C.

5. Remove the sealer and wash the plate 5 times with wash buffer. Soak wells with at least 0.35 ml wash buffer for 30 seconds to 1 minute for each wash. For automated washing, aspirate all wells and wash 5 times with wash buffer, overfilling wells with wash buffer. Blot the plate onto paper towels or other absorbent material.

6. Add 50μl substrate solution A to each well and then add 50μl substrate solution B to each well. Incubate plate covered with a new sealer for 10 minutes at 37°C in the dark.

7. Add 50μl Stop Solution to each well, the blue color will change into yellow immediately.

8. Determine the optical density (OD value) of each well immediately using a microplate reader set to 450 nm within 10 minuets after adding the stop solution.


Product Tags:
China Sheep Testosterone Accurate Quantitative Detection Enzyme Linked Immunosorbent Assay Kit supplier

Sheep Testosterone Accurate Quantitative Detection Enzyme Linked Immunosorbent Assay Kit

Inquiry Cart 0