Schneider STM2-63 3p MCB Circuit Breaker With Double Wiring 6ka Ce Semko


General

1. Application:For protecting cables and equipments against overload and short circuit.

2. General rules for choosing MCB.

  1. Technical data of the network at the point considered

The earthing systems,short-circuit current at the circuit breaker installation point,which must always be less than the breaking capacity of this device,network normal voltage.

  1. There are 3 curvve characteristics for magnetic operation:

B curve (3-5In) protection and control of the circuits against length cables in TN and IT systems.

C curve (5-10In) protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current.

D curve (10-14In) protection and control of the circuits against overloads and short-circuits; protection for circuits which supply loads with high inrush current at the circuit closing (LV/LV transformers,breakdown lamps.)


Specifications


CertificateCE
Satandard ranges of instantaneous trippingB-type, C-type, D-type
Rated voltage(V)230/400
Rated current(A)6, 8, 10, 13, 16, 20, 25, 32, 40, 50, 63
Rated frequency(Hz)50/60
Rated short-circuit capacity6000A(In<=40A), 4500A(In=50A/63A)
Number of poles1, 2, 3, 4
StandardIEC60898

StandardIEC/EN 60898-1
Electrical
features
Rated current InA1,2,4,6,10,16,20,25,32,40,50,63
PolesP1,2,3,4
Rated voltage UeV230/400V
Insulation voltage UiV500
Rated frequencyHz50/60
Rated breaking capacityA4500,6000
Rated impulse withstand voltage(1.2/50)UimpV4000
Dielectric test voltage at ind.Freq.for 1 minKv2
Pollution degree2
Thermo-magnetic release characteristicB,C,D
Mechanical
features
Electrical lifet4000
Mechanical lifet10000
Protection degreeIP20
Reference temperature for setting
of thermal element
30
Ambient temperature
(with daily average ≤35℃)
-5~+40(Special application please refer to
temperature compensation correction)
Storage temperature-25~+70
InstallationTerminal connection typeCable/Pin-type busbar
Terminal size top/bottom for cablemm225
AWG18-3
Therminal size top/bottom for busbarmm225
AWG18-3
Tightening torqueN*m2
In-lbs18
Mountingon DDIN rail EN 60715(35mm)by means of fast clip device