Home /Machine Tool Equipment /

Heavy Oil High Viscosity Oval Gear Flow Meter Digital Fuel Flow Meter LC Series

Heavy Oil High Viscosity Oval Gear Flow Meter Digital Fuel Flow Meter LC Series

Brand Name:Kacise
Minimum Order Quantity:1pcs
Delivery Time:5-8 working days
Payment Terms:L/C, T/T, Western Union, MoneyGram, D/A, D/P
Place of Origin:China (Mainland)
Supply Ability:10000pcs/month
Contact Now

Add to Cart

Verified Supplier
Address: i City, No11, TangYan South road, Yanta District, Xi'an,Shaanxi,China.
Supplier`s last login times: within 16 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details
oval gear flowmeter for heavy oil high viscosity digital fuel flowmeter and high temperature
Introduction
LC series oval gear flow meter is the main products of our company. LC oval gear flow meter is one of the typical displacement meter, used for measurement of pipeline fluid flow under certain pressure. It has a simple structure, reliable use and high accuracy, flow field has no special requirements for import and export of the pipe, the viscosity of the measured medium range and the characteristics of the flow range is very wide. And therefore is widely used in petroleum, chemical industry, medicine, transportation, food and other industrial and commercial sector of liquid flow detection. LC series oval gear flow meter is particularly suited to the measurement of oil fuel.
Usage
LC-A type cast iron oval gear flow meter, widely used in all kinds of oil products and for the measurement of the cast iron material not corrosion liquid medium.
LC-E type cast steel oval gear flow meter, Used for high pressure, low corrosive medium measurement.
LC-Q type cast iron oval gear flow meter, The rotor for aluminum alloy, is suitable for low viscosity, low corrosion, such as gasoline, etc.) the measurement of liquid medium.
LC-B, C type stainless steel oval gear flow meter, widely used in strong corrosive liquid medium, such as acid, alkali, salt and organic compounds, the measurement of liquid medium.
LC-L type Aluminum alloy oval gear flow meter, is a small oval gear flow meter, widely used in low corrosive liquid medium, such as water, such as the measurement of liquid medium.

Materials of main parts and the nominal operating pressure

Shell and covercover plateoval wheelRotary shaftbushingNominal pressure(MPa)
LC-ACast steelCast iron

Cast iron,Stainless steel

Alloy aluminum,

engineering material

Stainless steelBronze(with oil) or rolling bearing1.6
LC-ECast steelCast iron

Under DN50 6.3

DN80-100 4.0 6.3

DN150-200 2.5

LC-B,CStainless steelStainless steelStainless steelgraphite,rolling bearing1.6,2.5

Notes:1. 0Cr18Ni12Mo2Ti for type LC-C; 0Cr18Ni9Ti for type LC-B.

2. Flange is convex under 2.5MPa ,and roughness at 6.3 MPa;and both of the above at 4.0 MPa.


2. Accuracy class class 0.5,class 0.2

3. Operating temperature: series LC-A(-20℃~+60℃),series LC-B,E,L(-41℃~+60℃)

60℃~200℃(with high temp. radiator installed)

4 Explosion-proof mark: ExiaⅡCT5, dⅡBT4

5. Flow range: unit: m3/h

TypeDNViscosity (mPa. s)

<0.3

    0.3~0.8

      0.8~22~200

      200~1000


      1000~2000


      LC-10

      10



      0.2-0.5


      0.08-0.50.08-0.5

      0.05-0.5


      0.06-0.3

      0.03-0.3


      0.03-0.2


      LC-15

      15



      0.75-1.

      5

      0.3-1.50.3-1.5

      0.15-1.5

      0.3-3

      0.2-1.0

      0.1-1.05


      0.07-0.75


      LC-20

      20



      1.5-3


      1-30.5-30.5-3

      0.3-3

      1.5-15

      0.4-2.1

      0.2-2.1


      0.15-1.5


      LC-25

      25


      4-6


      3-6


      2-61-61-6

      0.6-6

      1.56-15

      0.8-4.2

      0.4-4.2


      0.3-3


      LC-40

      40


      9-15


      7.5-15


      5-152.5-152.5-15

      1.5-15


      2.1-10.5

      1.0-10.5


      0.7-7.5


      LC-50

      50


      10-24


      8-24


      8-244.8-244.8-24

      2.4-24


      2.4-16.8

      1.6-16.8


      1.2-12


      LC-B40,5040,508-206-206-204-204-202-202.8-141.4-141.0-10
      LC--65

      65


      27-40


      20-40


      15-408-408-40

      4-40


      5.6-28

      2.8-28


      2-20


      LC-80

      80


      40-60


      30-60


      20-6012-6012-60

      6-60


      8.4-42

      4.2-42


      3-30


      LC-100

      100


      67-100


      50-100


      34-10020-10020-100

      10-100


      14-70

      6-70


      5-50


      LC-150

      150


      127-190

      95-190


      64-19038-19038-190

      19-190


      26.6-133

      13.3-133


      9.5-95


      LC-200200227-340

      170-340


      114-34056-34056-340

      34-340


      47.6-238

      23.8-238


      17-170


      Accuracy class0.50.50.20.50.20.50.20.50.5

      Note: If the temperature of the metered liquid is higher than 80℃. the maximum flow fate will be 90% of the primary flow, and the minimum will be 120%.


      Installation and Operation

      • A strainer should be installed in front of the meter, and be sure that the arrows on the casting of the meter and the strainer pointing the same direction of the liquid flow.
      • If the metered media contains gas, a gas separator should be installed in front of the meter.
      • Whether the pipe line is vertically or horizontally installed, the wheel’s shaft of the meter must be fixed horizontal, that is, the dial is vertical to the surface.
      • While the meter is installed properly, the counter may be turned 180°or 90°for easy reading.
      • Prior to the installation of the new meter, first push the oval wheels from the outlet for several times with a bamboo rod, if the wheels don’t move, they can be immersed in the petrol to prevent from deposits in the meter after the factory’s inspection.
      • A throttle valve must be fixed at the inlet of the meter, an on-off valve at the outlet, which must be slowly activated to prevent from a sudden impact, reverse flow, and water hammer.
      • It is forbidden to clean the meter with steam.
      • For the continuous operated departments, a by-pass should be mounted.
      • Prior to the installation of the meter, the pipe line must be thoroughly cleaned,and at the time of cleaning use a straight pipeline in stead of the meter,to prevent impurity,welding residue from entering the meter.
      • It is forbidden to inspect the meter made of cast iron and cast steel using water.
      • During the operated of the meter the flow rate can’t exceed the flow marked on the mamelon plate. It is preferable to operate the meter at 50—80% of the max. flow.
      • If the metered media is causticity,stainless steel shall be selected.


      China Heavy Oil High Viscosity Oval Gear Flow Meter Digital Fuel Flow Meter LC Series supplier

      Heavy Oil High Viscosity Oval Gear Flow Meter Digital Fuel Flow Meter LC Series