China Categories
English
Home /

LCD Display Electromagnetic Flow Meter Stainless Steel Thermal Mass Flow Meter

LCD Display Electromagnetic Flow Meter Stainless Steel Thermal Mass Flow Meter

Brand Name:YGT
Certification:SGS,ISO .
Minimum Order Quantity:1 SET
Delivery Time:5-8 working days
Payment Terms:L/C, T/T
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Address: Room 604, Pujiang Building £3,Shangyin Road , Huaqiao town, Kunshan, Jiangsu Province, China
Supplier`s last login times: within 47 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Mass Flowmeter,mass coriolis flow meter flowmeter,air mass flow meter , Electromagnetic Flowmeter

The high performance signal converter for all applications

The MFC 400 Coriolis mass flow signal converter will provide the highest performance possible across a wide range of applications. For the measurement of liquids or gases, cryogenic to high temperature fluids, single or multi-phase fluids and advanced digital signal processing techniques is used to give stable and accurate measurements of mass flow, density and temperature.

It is developed according to IEC 61508 and depending on the I/O and flow sensor variant suited for use in safety applications SIL 2/3.

Conforming to the NAMUR standard NE 107 for status and error handling, the MFC 400 features enhanced meter diagnostics. This provides extensive self-checking of internal circuits and information regarding the health of the flow sensor, but just as importantly, vital information about the process and process conditions.

Highlights

• High performance signal converter with multiple output options

• Developed according to IEC 61508

• Safe configuration via local display or HART®

• Partial proof test capable

• Smart diagnostics, covering entire devices in less than a minute

• NE 107 status indicated by display background light

• Entrained Gas Management (EGMTM) – the new standard for entrained gas immunity

• Excellent long-term stability

• Optical and mechanical keys for ease of use

• Redundant data storage in signal converter housing

• Real time clock for logging events

• Overall, flexible lock concept

• HART® 7

Industries

• Water & Wastewater

• Chemicals

• Power plants

• Food & Beverage

• Machinery

• Oil & Gas

• Petrochemical

• Pulp & Paper

• Pharmaceutical

• Marine

Applications

• Liquids and gases

• Liquids with gas entrainment

• Slurries and viscous products

• Concentration measurement for quality control

• Measurement of volume flow

• Measurement of density and reference density

• Custody transfer loading/unloading

• Custody transfer measurements

Options and variants

The MFC 400 mass flow signal converter is available in different variants and offers superior performance in any conceivable application. From process control in chemistry, to density and concentration measurements in the food and beverage industry, to custody transfer filling and transport measurements for oil and gas right down to conveyor systems in the pulp and paper industry.

Coriolis mass flow measuring systems measure the mass and volume flow, the density and the temperature of liquids and gases. In addition, the concentration in mixtures and slurries can also be determined.

Thanks to Entrained Gas Management (EGMTM) the MFC 400 systems offer high performance with air entrainment, delivering continuous measurement even with 0...100% gas entrainment.

For standard applications the compact housing is mounted directly on the measuring sensor. In the unlikely event of a failure, the electronics can be easily exchanged and reconfigured using a backup data set that is stored in the housing.

The signal converter in the robust field housing is generally used when it is difficult to access the measuring point or when ambient conditions do not allow the use of the compact version.


Insertion TypeSegment Type
Measuring mediaVarious gases (except for acetylene gas)
Range of pipe diameterDN80-6000 mmDN15-2000 mm
Velocity range0.5-100 Nm/s
Accuracy±1.0%
Working temperatureSensor: normal temperature type -10℃ to +200℃, high temperature type -10℃ to +350℃; converter:-20℃ to +45℃ (for special environment, please specify)
Working pressureMedia pressure≤2.5MpaMedia pressure≤4.0Mpa
Power supplyIntegrated type machine (DC24V or AC220V ≤18W), detachable converter (AC220V ≤19W)
Response speed1S
Output signal4-20mA (photoelectric isolation, maximum load 500Ω)
RS-485 (photoelectric isolation)
Pipeline materialCarbon steel, stainless steel and plastic, etc.
DisplayIntegrated type: 8-bit field + 24 prompts
Detachable type: 10x2 Chinese characters
Display contentMass flow, volume flow under normal condition, integrated flow, standard time and integrated runtime, etc.
Outline of detachable converterWall-hanging type: 213x185x107mm
Panel-mounting type: 160x80x160mm
Distance between detachable converter and primary instrument≤25m(primary instrument is powered by detachable converter),
≤1000m (primary instrument is powered on the site)
Degree of protection of detachable converterWall-hanging type: IP65
Panel-mounting type: IP52
Degree of protection of primary instrumentIP67
Explosive-proof grade of primary instrumentExdⅡCT4
Sensor materialsStainless steelsStainless steel, carbon steels

China LCD Display Electromagnetic Flow Meter Stainless Steel Thermal Mass Flow Meter supplier

LCD Display Electromagnetic Flow Meter Stainless Steel Thermal Mass Flow Meter

Inquiry Cart 0