30kva Three Phase Isolation Transformer , Delta Online Ups GP3330K

30kva Three Phase Isolation Transformer , Delta Online Ups GP3330K

Brand Name:CPSY
Certification:CE.TLC
Model Number:GP3330K
Minimum Order Quantity:1unit
Delivery Time:25-35days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Active Member
Location: Shenzhen Guangdong China
Address: 4F block A,Building 1, Senyang High Technology Park, Guangming New District, Shenzhen, China.
Supplier`s last login times: within 40 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

30KVA/24KW full protection online ups isolate transformer 3-phase low frequency UPS


3/3 low frequency ups


a. Application


small and medium sized data centers,Server,critical network devices, sensitive electronic equipment,small rooms, small precision electronic instrument


b. Functions & Features


1) DSP Technology

2) Superior overload capability

3) Large LCD display and LED indicator

4) 50/60Hz source auto detection

5) Emergency Power Off (EPO)

6) Advanced battery charging management

7) N+X parallel redundancy

8) Fault detection and alarming

9) The efficiency of the machine is more than 93%, and reach 98% in ECO mode.

10) High security dual ac power input function

11) The frequency and phase sequence adaptive system

12) Powerful panel Settings function

13) Intelligent RS485+SNMP+AS400 communication port


Parameter:


ModelGP3310KGP3315KGP3320KGP3330KGP3340KGP3360KGP3380K
Capacity10KVA/8KW15KVA/12KW20KVA/16KW30KVA/24KW40KVA/32KW60KVA/48KW80KVA/72KW
INPUT
Norminal Voltage3*380VAC/400VAC(3PH +N)
Acceptable voltage range285VAC~475VAC
Frequency Range50Hz/60Hz±10%
INVERTER
Norminal voltage380V
Precision380V±25%
Frequency50Hz/60Hz
WaveformPure Sine wave
Total Harmonic Distortion(THDv)≤2% (linear load); ≤5% (non-linear load)
Phase Displacement120°±1%(balanced load); 120°±2%(imbalances 50% of the load)
Dynamic Recovery Time3 cycles at 90% of the static value
Admissible Overload110% for 10min;150% for 60sec;>160% for 200ms
AdmissibleCrest Factor3:01
Admissible Power factor0.6~1(inductive or capacitive)
Imbalance output voltage@100% unbalanced load<1%
Current limitHigh overload, short circuit, RMS voltage limit, High Crest-factor Curren, Peak voltage limit
STATIC BYPASS
TypeSolid state
Voltage3*380VAC/400VAC(3PH +N)
Frequency50Hz/60Hz
Activation CriterionMicroprocessor control
Transfer timeZero
Admissible Overload150% for 1hour;180% for 30sec;>200% for 200ms
Transfer to BypassImmediate, for overload above160%
RetransferAutomatic after alarm clear
MAINTENANCE BYPASS
TypeWithout Interruption
Voltage3*400V(3PH+n)
Frequency50Hz/60Hz
Overall Efficiency(line mode)Line mode105%±5% ≤load,warning overload;
Battery Mode105%±5% <load≤125%±5% Transfer to bypass and Alarming after 2 mins;
BATTERY & CHARGE
Battery type & Number12VDC*32pcs(29~32pcs adjustable)
Normal Battery Voltage384VDC(Based on 32pcs batteries)
Charging MethodCC/CV
Charging CurrentDefault 10A, Max.=capacity(KW)/battery voltage(real time)Default 10A, Max.40A;5A@ full load
Charging Voltage432VDC(Based on 32pcs batteries)
Safety requirementsGB4943-2001/IEC62040-1 EMC/EMI, IEC 61000-4-5 Protection surge
Noise(1m)≤55dB
PHYSICAL
Dimension,D×W×H (mm)656×405×817656×405×941821×432×1159975×554×1286
Net Weight(KGS)118120145193278365471