Home /Electrical Wires /

High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215

High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215

Brand Name:SUNWIN
Certification:ISO9001, ISO14001, OHSAS18001
Minimum Order Quantity:Negotiable
Delivery Time:10 day
Payment Terms:30% deposit, the balance is settled on the delivery date
Name:Overhead Power Lines
Contact Now

Add to Cart

Active Member
Location: Guangzhou Guangdong China
Address: No. 23, Dongzhi Rd, Guangzhou Development District, Guangzhou, Guangdong, China.
Supplier`s last login times: within 26 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215


APPLICATION

AAAC is used as a bare overhead conductor for power transmission and distribution lines, on aerial circuits that require a larger mechanical resistance than AAC, and a better corrosion resistance than ACSR. The sag characteristics and the strength-to-weight ratio of AAAC is better than both AAC / ACSR.


CONSTRUCTION

Conductor

Aluminium alloy conductor Type AL2 to AL7 as per EN 50183 to BS 215


CABLE STANDARDS

ASTM - B 399 Metric Units, ASTM - B 231, TS IEC 1089, DIN 48201, BS 215, UNE 21.018


The electrical and dimensional properties of this product are measured by the Technical and Quality Assurance department at the Cables laboratory. Cable performance in respect of conductor resistance, construction quality (workmanship), dimensional consistency, and other parameters are verified to published standards and approved product drawings. Conformance to RoHS (Restriction of the use of Hazardous Substances) is determined and confirmed.


DIMENSIONS

ASTM Sizes


CODE

SIZE

KCM

STRANDING

DIAMETER

inches

NOMINAL CROSS SECTIONAL AREA

(sq ins)

WEIGHT

lbs/1000ft

RATED STRENGTH

(lbs)

RESISTANCE

ohms/1000ft

CURRENT RATING

Amps

SIZE

ACSR WITH EQUIV.DIAM. STRANDING

Alt/Stl

Individual wiresTotal

DC

20ºC

AC

75ºC

AKRON30.5870.06610.1980.02428.711100.6590.785107661
ALTON48.6970.08340.250.038245.717600.4140.493143461
AMES77.4770.10520.3160.060872.728000.260.31191261
AZUSA123.370.13270.3980.0968115.744600.1630.1952561/061
ANAHEIM155.470.1490.4470.1221145.953900.130.1542962/061
AMHERST195.770.16720.5020.1537183.767900.1030.12303423/061
ALLIANCE246.970.18780.5630.1939231.885600.08160.09733954/061
BUTTE312.8190.12830.6420.2456293.6110000.06440.0769460266.8267
CANTON394.5190.14410.7210.3098370.3133000.05110.061532336.4267
CAIRO465.4190.15650.7830.3655436.9156000.04330.0518590397.5267
DARIEN559.5190.17160.8580.4394525.2188000.0360.04316634772617
ELGIN652.4190.18530.9270.5124612.4219000.03090.0371729556.52617
FLINT740.8370.14150.9910.5818695.5244000.02720.0327790636267
GREELY927.2370.15831.1080.7282870.4305000.02170.0263908795267

Resistance is calculated using ASTM standard increments of stranding, and metal conductivity of 52.5% IACS. AC resistance at 60 Hz.

Current ratings are based on 75ºC conductor temperature, 250ºC ambient, 2 ft/s wind, 96/watts/sq.foot sun, 0.5 coefficients of emissivity and absorption.


ASTM Sizes


CONDUCTOR SIZE

c mil

AREA

mm2

NO. AND DIAMETER OF WIRESOVERALL DIAMETER OF CONDUCTORLINEAR WEIGHT

RATED STRENGTH

lb

MAXIMUM DC RESISTANCE AT 20ºC

ohms/km

inchmminchmmkg/kmdaN
6636033.627 x 0.09747 x 2.470.2917.41931068240.9942
10560053.57 x 0.12287 x 3.120.3689.36148169738150.6256
13310067.447 x 0.13797 x 3.50.41310.5187205246120.4959
16780085.027 x 0.15487 x 3.930.46411.823525865810.3936
211600107.217 x 0.17397 x 4.420.52213.26296326373320.3119
400000202.6819 x 0.145119 x 3.680.72418.45605974134260.165
45000022819 x 0.153919 x 3.910.76919.5563067191510.1487
500000253.3519 x 0.162219 x 4.120.81120.67004764167740.1321
550000278.6837 x 0.121937 x 3.10.85421.77698380188350.1202
60000030437 x 0.127337 x 3.230.8922.68399138205350.1102
650000329.3537 x 0.132537 x 3.360.92623.529109494213360.1016
700000354.737 x 0.137537 x 3.490.96224.4397810220229670.0944
75000038037 x 0.142437 x 3.610.99525.2710501094024630.088
800000405.3637 x 0.14737 x 3.731.0226.1111811680262480.0826
90000045637 x 0.15637 x 3.961.0927.72126013150295510.0733
1000000506.737 x 0.164437 x 4.171.1529.2140014610328320.066

ASTM Sizes Metric Units


CODE

SIZE

KCM

NOMINAL SIZE

mm2

STRANDING

DIAMETER

inches

WEIGHT11

lbs/1000ft

RATED STRENGTH2

kg

RESISTANCE3

ohms/1000ft

CURRENT RATING4

Amps

SIZE

mm2

ACSR WITH EQUIV.DIAM. STRANDING

alt/stl

Individual WiresTotal

DC

at 20ºC

AC

at 75ºC

AKRON30.5815.571.6795.0442.75032.162.5710713.36/1
ALTON48.6924.6772.1186.36687981.361.6214321.156/1
AMES77.4739.2572.6728.02108.212700.8531.0219133.636/1
AZUSA123.362.4873.37110.11172.220230.5360.63925653.316/1
ANAHEIM155.478.7473.78511.35217.124450.4250.50929667.446/1
AMHERST195.799.1674.24712.74273.330800.3380.40334285.036/1
ALLIANCE246.9125.174.7714.31344.938830.2680.319395107.226/1
BUTTE312.8158.5193.25916.29436.949890.2110.252460135.1926/7
CANTON394.5199.9193.6618.3551.160330.1680.2532170.4626/7
CAIRO465.4235.8
China High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215 supplier

High Voltage Overhead Power Lines Overhead Electrical Wire DIN 48201 BS 215

Inquiry Cart 0