FDA 0.96" LCD Adult Medical Portable Digital Finger Pulse Oximeter

FDA 0.96" LCD Adult Medical Portable Digital Finger Pulse Oximeter

Brand Name:UNIFORM
Certification:CE, ISO, FDA
Model Number:AUTC-DPO-338
Minimum Order Quantity:Negotiable
Delivery Time:20-25 days
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Hefei Anhui China
Address: No. 3, Qiaowan Road, Feixi Economic Development Zone, Hefei City, Anhui Pro. (231200), China
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Digital Finger Pulse Oximeter For Adult Medical Diagnostic Finger Pulse Oximeter


Products Description


1) Integrated SpO2 sensor and display module
2) Small in volume, light in weight and convenient in carrying
3) Easy to operate, low power consumption
4) Operation menu for function settings
5) SpO2 value display
6) Pulse rate value display, bar graph display
7) Pulse waveform display
8) Display direction can be changed
9) Screen brightness can be changed
10) Pulse rate sound indication
11) With measured data overruns limits and low-voltage alarm function, the upper/lower alarm limit can be adjusted
12) Battery capacity indication
13) Low-voltage indication: Low-voltage indication appears before working abnormal caused by low voltage.
14) Data storage function, stored data can be uploaded to computer
15) Data transmission in real-time


Products Specification


Display mode :
0.96" Dual-color OLED display(blue and yellow)
Screen resolution :
128*64
SpO2 measuring range :
0%~100%, (the resolution is 1%).
Accuracy :
70%~100%: ±2%, Below 70% unspecified.
PR measuring range :
30bpm~250bpm, (the resolution is 1bpm)
Accuracy :
±2bpm or ±2% (whichever is greater)
Measurement performance in weak filling condition :
SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2bpm or ±2%
(whichever is greater).
Resistance to surrounding light :
The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less
than ±1%.
)Power consumption :
no more than 100mA
Voltage :
DC 3.6V~4.2V
Power supply :
3.7V rechargeable lithium battery × 1
Battery working hour :
20 hours in theoretical
Battery service life :
no less than 500 times of charge and discharge
Safety type :
Internally powered equipment, Type BF applied part