登录 | 免费注册 | 提交网站 | 免费看询盘 | 外贸旺站免费建站 | "贸易通"多语言推广 | 外贸论坛
Hot Products:
Home > Power Supplies >

CE Approved High Performance Inverter Step Down Transformer 380V To 220V AC Motor Drive

CE Approved High Performance Inverter Step Down Transformer 380V To 220V AC Motor Drive

Brand Name: CANWORLD
Certification: CE, ROHS, ISO9001
Model Number: CDE500-4T110G
Minimum Order Quantity: Negotiable
Delivery Time: 5-14days
Payment Terms: T/T, Western Union, MoneyGram, L/C, D/A
Chengdu Bebort Electric Equipment Co., Ltd.
Verified Supplier
Chengdu Sichuan China
Business type: Manufacturer
7-5-706#, Dajian Road 280#, Shuangliu District Chengdu City, SC China 610225
Supplier`s last login times: within 41 hours

Step down transformer 380v to 220v ac motor drive vfd 3 phase inverter


CDE500 Technical Specifications


ItemSpecifications
Basic PerformanceRated Input

Single-phase: 220V;
Three-phase : 220V/380V/480V/690V/1140V;
Frequency: 50/60Hz

Input voltage range

Voltage fluctuation: -15%~10%;
Imbalance factor: less than 3%;
Voltage frequency: 47~63Hz

Control modeVF control; Open-loop vector control; Close-loop vector control
Frequency resolution

Digital setting: 0.01Hz;
Analog setting: 0.5% × maximum frequency

Maximum outputV/F control: 3500Hz; Vector control: 300Hz
Speed rangeVF control: 1:60; Vector control: 1:100
Carrier frequency0.5~16.0kHz(Model dependent). The carrier frequency can be automatically adjusted based on features of the load.
Start torque0.5Hz/150%*rated motor torque
Overload capacity

G type: 150% rated current for 60s,180% rated current for 3s
L type: 120% rated current for 60s

Basic FunctionRun modeKeypad; Control terminals (two-line, three-line); Serial communication (RS485).The user can perform switch-over between these sources in various ways.
V/F curveStraight line type; Multiple point type; N-power type
Ramp curveStraight line or S curve; Four ramp times (range: 0.1s to 6000.0s)
Torque boostAutomatic/manual torque boost
Speed traceAll types have the function of the speed trace.
Motor brakingDC braking; Energy consumption braking; Magnetic braking
DC braking

Braking frequency: 0.00Hz to Maximum frequency;
Braking time: 0.0s to 100.0s;
Braking current: 0.0% to 100.0%*Rated motor current

Magnetic braking

For occasions which have the request of fast stop or regenerative
loads, the function of magnetic braking can be used. The function
can avoid frequent protection due to over voltage.

CBC current limiting

The function of CBC current limiting is to minimize the fault of over
current and keep the normal running of the AC drive.

Overcurrent and overvoltage control

The function is to restrict the current and voltage automatically
during running and avoid the frequent fault protection of over
current and over voltage.


ItemSpecifications
Special FunctionsThe delay time of terminalsThe user can set the delay time for digital input terminals, digital output terminals and relays.The time range is 0.0s to 3000.0s.
JOG Control

Control mode: keypad, terminals and serial communication.
Frequency: 0.00Hz to Maximum frequency;
Ramp time: 0.1 to 6000.0s

Multiple speed and simple PLC

Based on built-in PLC or digital input terminals, realize the
running of sixteen segments speed.

Two PID inside the parametersAs common PID, the closed-loop system of process control can be realized easily.
Fixed length and count

The AC drive can count the pulse signal of 0 to 100K Hz and realize
the control of count reaching by using digital output terminals.The drive can also convert the count into length for display and control.

Spinning and swing frequencyThe fixed swing magnitude, fixed mutations and fixed periodic output can be achieved at arbitrary frequency.
Timing control

Time range: 0 to 65000 hours.
The timing control can stop the AC drive.

Power loss ride throughWhen the power loss ride through happens, by decreasing the running frequency, the feedback energy of the load can compensate the voltage drop of the DC bus. As a result, the AC drive can keep running for a short time.
Peripheral terminalsReference power

10V/30mA.
Usually, it is used for the power supply of analog input signals.

Control power24V/200mA.Usually, it is used for the power supply of digital input and output terminals.
Analog input

Two analog input terminals, which have two types of voltage input and current input.
Every input terminal can support three types input signals: 0 to 10V, 0 to 20mA and -10V to 10V.
These two analog input terminals are programmable.

Analog output

Two analog output terminals, which have two types of voltage output and current output.
Every output terminal can support two types output signals: 0 to 10V and 0 to 20mA.
These two analog output terminals are programmable.

Digital inputSix multi function digital input terminals are compatible with active PNP or NPN input mode. Among these six input terminals, the X6 terminal can be chosen as high-speed pulse input terminal and the range of the high-speed pulse is 0 to 100KHz. At the same time, the X6 terminal is programmable.
Digital outputThere are two open collect output terminals. Among them, Y2 terminal can be chosen as high-speed pulse output. These two output terminals are programmable.There are two relay output terminals.
ItemSpecifications
Protection functionCommon typesInput and output phase loss protection,under voltage protection, over voltage protection,over current protection,over heat protection, over load protection,short-circuit protection, module fault, external fault, self-defining fault.
EnvironmentInstallation locationIndoor, free from direct sunlight, dust,drip, salt, oil smoke, water vapor, combustible gas and corrosive gas.
Altitude

If the altitude is equal or lower than 1000 meters, the AC drive can be used normally.
If the altitude is higher than 1000 meters, it is necessary to de-rate the AC drive. The ratio of derating the AC drive is 1 percent for every increase of 100 meters.
If the altitude is higher than 3000 meters, please contact our agents.

Temperature

-10℃ to +40℃.
If the ambient temperature is 40℃ to 50℃, please keep good ventilation and take the action of derating: The ratio of derating the AC drive is 3 percent for every increase of 1℃.

HumidityLess than 95%RH, without condensing.
VibrationLess than 0.6g
Storage temperature-25℃~+65℃


Product Tags:

ac power inverter

      

vfd inverter

      

CE Approved High Performance Inverter Step Down Transformer 380V To 220V AC Motor Drive Images

Send your message to this supplier
From:
Enter your email please.
To: Chengdu Bebort Electric Equipment Co., Ltd.
Subject:
Message:
Characters Remaining: (0/3000)
 
Inquiry Cart 0
Other about

CE Approved High Performance Inverter Step Down Transformer 380V To 220V AC Motor Drive

3 Phase 380V High Performance Inverter VFD / VSD / VVVF / Frequency Inverter

Brand Name :CANWORLD
Certification :CE, ROHS, ISO9001

220V 240V Three Phase Pump Inverter 140 - 1500VAC Input / Output Voltage

Brand Name :CANWORLD
Certification :CE, ROHS, ISO9001