Home /Mining Machinery /

Small Volume Partial Discharge Test Equipment / Partial Discharge Measurement Equipment

Small Volume Partial Discharge Test Equipment / Partial Discharge Measurement Equipment

Brand Name:Fanke High-Voltage
Certification:ISO9001
Model Number:JF2002
Minimum Order Quantity:One unit
Delivery Time:20~25 work days
Payment Terms:T/T
Contact Now

Add to Cart

Active Member
Location: Wuhan Hubei China
Address: Layers Building 2,N0.2-2 Guannan Science&Technology Industrial Park, East Lake High-Tech Development Zone,Wuhan ,China
Supplier`s last login times: within 39 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Partial Discharge Detecting Tester , PD Detecting Instrument , Impulse Current Method PD Tester


1.Product introduction:


Due to manufacturing or installation defects, discharge occurs in the insulated portion of the live cable end (joint) until insulation breakdown damage occurs, and even a fire or explosion at uncertain defects may occur. Therefore, how to find the hidden troubles before the accident is the key to solve the problem, which makes the discharge detection necessary for power equipments.


The model JF2002 is a kind of impulse current method partial discharge inspection instrument It has the feature of small volume, excellent performance and easy operation.


II.Main Components:


SNName of equipmentType and specificationUnitQty
1Host machineJF-2002Piece1
2JZF Series calibratorJZF-10Piece1
3Amplifierpiece1
4Input signal unitSN 2, 3,4set1
5Standard connection wireSet1

III. Detecting principle figure

Note : The PD free test transformer set (power frequency voltage withstand test set) rises the target testing voltage to tested object (such as power transformer ,CB, bushing, CT,PT ,discloser and so on )which PD detecting needed , the coupling terminals of voltage divider will has some PD coupling signal to the PD detecting tester JF 2002, then get the PD level from the tested object.


VI. Technical Parameters of PD tester JF2002

1.Keywords: time base frequency ,Display, Change with measurement fuctions

  • Time base frequecny: 50,100,150,200,400Hz power supply : 50HZ 220V
  • Display: Ellipse---Expand---Beeline
  • Change with measurement fuctions

2.Integrated design, covering 10kHz~300kHz, Meet IEC60270 standard.

3.Capacitance range of measured object: 6pF~250uF

Measuring sensitivity and Max. Current as the table


Input unit SN.optionalMeasured object Cx rangeSensitivity(PC)Permitted circuit current
Imbalance circuitBalance circuit
10~25~100pF0.0230mA0.25A
225~100~400pF0.0450mA0.5A
3100~400~1500pF0.06120mA1A
4400~1500~6000pF0.10.25A2A
51500~6000~25000pF0.20.5A4A
60.006~0.025~0.1μF0.31A8A
70.025~0.1~0.4μF0.52A15A
80.1~0.4~1.5μF14A30A
90.4~1.5~6.0μF1.58A60A
101.5~6.0~25μF2.515A120A
116.0~25~60μF525A200A
1225~60~250μF1050A300A
7Rpure resistance0.52A15A

4.Time base of ellipse scan:

  • Frequency 50/60(inner), 100,150,200,400Hz
  • Turn:30°per grade, total 360°
  • Display ways:Ellipse---Expand---Beeline
  • The high frequency time base ellipse can be adjusted to normal state by input voltage (10~250V), and the power is less than 1VA. Auto-protecting function when overload

5.Displaying Unit:

A reactangle oscillograph tube(124×104mm2), which has brightness and focus knobs


6.Amplifier :

  • On low frequency 3dB, fL: 10,20,40kHz optional
  • On high frequecny 3dB, fH: 80,200,300kHz optional
  • Gain adjusting: 6 grades of gross adjustment. Gain difference between grades is 20+ 1dB,fine adjusting range >20dB
  • Asymmetry of plus and minus pulse responding <1dB

7.Time window

  • Adjustable window width,15°~150°on 50/60Hz
  • Rotatable window position, 0°~170°
  • Two windows can on/off respectively or simultaneously
  • Bombarding device, 20mS time to taking pictures

8.Pulse peak meter

  • Pointer meter with linear scale, 0~100 deviation + 5%(with full scale)
  • Pointer meter with logarithm scale, 0~10~100 deviation + 5%(with full scale)
  • Pointer meter with 3.5bits LED digital display, 0~100 deviation + 3%(with full scale)

9.Measuring voltmeter

  • Measuring range :100KV(with 100KV voltmeter resistance R)
  • Display :3.5bits LED digital , deviation + 3%

10.Zero mark system

  • Made by inner zero mark generator, it can change polarity and rotate 0~180°,so it can correspond with the true zero mark, which is made by high voltage resistor.
  • The zero mark is corresponded with all ellipse scan frequecny.

11. Dimension : 530×550×220mm weight :22kg


VII. Optional model

  • Model JF 2002 : PD test channel one channels
  • Model JF 2003 : PD test channel three channels
  • Model JF 2004 : PD test channel four channels

VIII. Optional matched other test set

  • PD detecting AC high voltage generating systems : CQSB series PD free power frequency test transformer systems
  • PD signal coupling unit : Coupling voltage divider or standard coupling capacitor , no corona type

China Small Volume Partial Discharge Test Equipment / Partial Discharge Measurement Equipment supplier

Small Volume Partial Discharge Test Equipment / Partial Discharge Measurement Equipment

Inquiry Cart 0