Home /Laser Beauty Equipment /

Tattoo Removal Q Switch ND YAG Laser Machine 755nm/1064nm/532nm/1320nm

Tattoo Removal Q Switch ND YAG Laser Machine 755nm/1064nm/532nm/1320nm

Brand Name:ADM Laser
Certification:CE
Model Number:AD-HQ
Minimum Order Quantity:1
Delivery Time:3-5 days
Payment Terms:L/C, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: ROOM 402 BUILIDING 5 SOARING BUILDING FUFENG ROAD FENGTAI DISTRICT BEIJING CHINA
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

1064nm 532nm 1320nm 755nm NDYAG Qswitch Laser Tattoo removal Pigmentation reduce Laser machine


AD-HQ descriptions : .

ADM Laser Portable Portable ND.YAG Qswitch Laser is mainly designed for the "Tattoo removal" treatment .The High-power laser bars with the double cooling radiators support the 15 hours continously working time . The average energy of every shoot stimulates collagen by destruction of pigmented cells ,and it's effective to general skin for regenerating after peeling improving loosing skin ,and minizing large pores.


Working principles : .



Q-Switched Nd: YAG adopts the latest Q-switched model, makes the cure time of laser to be smallest, avoiding damage to the skin. And the skin tissue absorbs the high energy of the certain laser wavelength in instant, then expands and explodes to tiny thing easily. Then licked up by the cell and be got out of the body


Machine Features: .

  1. Accurate energy of every shoot
  2. One time - tattoo removal laser
  3. 8inch LCD touch screen
  4. 15hours contiously working time
  5. Four different wavelength for all color removal .(755nm/1064nm/532nm/1320nm)
  6. Metal structure designs
  7. No side effect, no scar, no down time
  8. Micro computer counts the shoots


Treatment must know: .

Purify of Embroider Eyebrow

  • First finds out if the customer has scar physique, or change skin or allergic skin. If they are covered eyebrow, or purify of embroider eyebrow, tattoo with other methods before, then use the weak (low) energy big facular to remove, but cannot remove to get a bleed.
  • Before purify of embroider the stabbed eyebrow, should scrape off the eyebrow first. Set optical frequency at 3-5Hz, the treatment head is apart from the skin from 0-3 cm.
  • The 1064nm laser is used to purify the black and blue-stabbed eyebrow. If the color present out after 5-10 minutes, we can purify for the second. Select the stronger energy to crush the pigment and promotes the organism absorption. Reexamines after 6 weeks, if the pigment or the light pigment trace is not shed, carry on treat once more.
  • Purify of embroider pink color tabbed eyebrow may use 532nm wavelength directly.
  • Purify the scarlet red and brown color eyebrow can use 1064nm wavelength first, then use the 532nm wavelength again. After 6 weeks, use the 532nm wavelength to carry on the second treatment.
  • The treatment interval of 6 weeks between two treatments. Treat periodically until clean up.
  • Suggestive number of treatment need: 1-3 times

Purify of Eyeliner

  • Must insure strict protection for the eyeball; the damage of eyeball created by laser is irreversible.
  • Set light frequency at 3-5Hz, and select low energy, small light spot, the treatment head is apart from the skin 0-3cm. The operator can use 1cm thick gauze to protect the eyeball of the patient.
  • Purify the lower eyeliner request the patient to close eye tightly, and the eyeball see upwards. The operator suppress the gauze with the index finger, suppress and push the upper eyelids upwardly, the middle finger pokes the lower eyelid to reveal the eyeliner, carry on the fast treatment with speed of light 3Hz. Advise the patient if feeling painful, do not move and tell the doctor to pause.
  • Purify the upper eyeliner requests the patient to close eye tightly, and the eyeball see downwards. The operators suppress the gauze with the middle finger, suppress the eyelid to underneath, the index finger push the upper eyelid upwards to reveals the eyeliner, and carry on the treatment with speed of light 3Hz.
  • Do not use the anesthetic as far as possible. After 6 weeks, carry on treats once more to deep part.
  • The treatment interval of 6 weeks between two treatments. Treat periodically until clean up.
  • Suggestive number of treatment need: 1-3 times

Purify Soak Lip and Lips Line

  • While purify the red lips line and red lips, choose corners of the mouth first for experiment. If the test spot change immediately to black after the laser strike, cannot purify again.
  • 2, Set light frequency at 3~5Hz, the treatment head should apart from the skin 0-3cm.
  • While purify black, scarlet red and the deep coffee color lips, purify with the 1064nm wavelength first, follows closely with the 532nm wavelength. After 6 weeks, carry on the second treatment with the 532nm wavelength.
  • Purify the pink red and red lips with the 532nm wavelength directly.
  • Notice: All the lip line and soak lips should carry on treatment after 6 months, otherwise the surgical will fail.
  • The treatment interval of 6 weeks between two treatments. Treat periodically until clean up.
  • Suggestive number of treatment need: 1-3 times

Purify Tattoo and Wound Tattoo

  • Set a light frequency at 3Hz or 5Hz, the treatment head is apart from the skin 0-3 cm, use the small light spot and high energy possibly.
  • The operation skill is as same as purify soak eyebrow.
  • The bigger area only purify once time then, do not purify again as far as possible. Avoid the energy gathering to create the skin swelling or the blister.
  • The treatment interval of 6 weeks between two treatments. Treat periodically until clean up
  • Suggestive number of treatment need: 1-4 times

Purify Old-age Spot and Nevus

  • Set a light frequency at 3~5Hz and the treatment head is apart from skin 0-6 cm. Choose small light spot and high energy.
  • Purify the old-age spot should use the 1064nm wavelength at first until the spot of bleeding appears. Change to 532nm wavelength to purify if no reaction.
  • Adopt the 1064nm wavelength to purify nevus generally, change to 532nm wavelength to purify if have no reaction.
  • The treatment interval of 6 weeks between two treatments. Treat periodically until clean up.
  • Suggestive number of treatment need : 1-2 times

Purify Birthmark and Nevus of OTA

  • Set a light frequency at 3Hz or 5Hz, the treatment head is apart from the skin 0-4 cm. Choose the small light spot and high energy.
  • Strike the trouble place until it seep the blood.
  • Best carry on the treatment with the 1064nm wavelength.
  • The treatment interval of 6 weeks between two treatments. Treat periodically until clean up.
  • Suggestive number of treatment need: 3-5 times

Purify Coffee-spots, Freckles and Yellow Brown Spot

  • Set a light frequency at 3Hz or 5Hz, the treatment head is apart from the skin 0-4 cm. Choose the small light spot and high energy.
  • Continuously strike the trouble place with the 1064nm wavelength about 15 minutes.
  • The treatment time avoids June, July, August and September every year.
  • The yellow brown spot can be cured by this machine. Suggest using carefully because of responding phenomenon.
  • The treatment interval of 6 weeks between two treatments. Treat periodically until clean up.
  • Suggestive number of treatment need: 2-5 times


Specifications: .

ItemDescriptions
Control panel8inch LCD touch screen
Working FrequencyAdjustable range: 1HZ ~6HZ ;
Main power supply1200W
Wavelength of laser1064nm (golden)/ 532nm (green) / 1320nm (black doll)/755nm (Red)
Light controlQswitch technology
Energy of laser10~2000 mJ/cm2
Width of pulse0-10ns
Alarm systemTemp alram + water alarm+ Shoot alarm
Safety dectectionAlways
Rate power of the machine1500W
Cooling systemWater cooling + Fans cooling
Light spot1-10mm
Power

AC230V±10%,50Hz±1Hz

AC110V±10%,60Hz±1Hz

Net weight20kgs
Package size66cm*51cm*53cm

Treatment handpiece: .

►755nm Wavelength►1064nm Wavelength ► ​​532nm wavelength ►1320nm wavelength


Relate products:


China Tattoo Removal Q Switch ND YAG Laser Machine 755nm/1064nm/532nm/1320nm supplier

Tattoo Removal Q Switch ND YAG Laser Machine 755nm/1064nm/532nm/1320nm

Inquiry Cart 0