Home /Hardness Testers /

MITECH MHBS-3000 Accurate measurement Stable and reliable Digital Display Brinell Hardness Tester

MITECH MHBS-3000 Accurate measurement Stable and reliable Digital Display Brinell Hardness Tester

Brand Name:Mitech
Certification:CE,GOST,ISO..
Model Number:MHBS-3000
Minimum Order Quantity:1 SET
Delivery Time:8-10 days after paid
Payment Terms:T/T, Western Union,Paypal
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: Room E506, YingChuangDongLi Park, 1# of ShangDi East Road, Haidian District, Beijing, China
Supplier`s last login times: within 35 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

MITECH MHBS-3000 Digital Display Brinell Hardness Tester

Overview

MITECH MHBS-3000 Digital Display Brinell Hardness Tester, based on the mechanical principle of hard alloy indenter pressing into the sample surface to produce indentation, realizing the material hardness measurement by measuring the diameter of the indentation.It is novel and high reliable with accurately measurement. With LED display, simple operation, it can visually display the test results to meet the hardness testing requirement for the quality control and qualified assessment of the workpiece sample. It is widely used in metal processing and manufacturing, various metal material’s failure analysis and other fields like colleges and research institutions It’s to improve the work efficiency, product qualification rate, saving production costs necessary professional precision testing equipment.

Technical Parameters

Technical specificationsTechnical Parameters
The power series

612.5N(62.5kgf),980N(100kgf),1225N(125kgf),1837.5N(187.5kgf), 2450N(250kgf),4900N(500kgf),7350N(750kgf),9800N(1000kgf),

14700N(1500kgf),29400N(3000kgf)

Measuring range8 – 650 HBW
Testing Force Application ModeAutomatic (loading, holding, unloading)
Indenter objective lens conversion modemanual operation
display usageLCD liquid crystal display
Microocular magnification20X
Test force holding time0~60s
Minimum division0.005mm
Max sample height225mm
Max sample width270mm
Max distance from head to body135mm
VoltageAC 220V/50Hz
Size786*565*245mm
Total Weight130kg

Indication accuracy


Standard Block

Indicating Error%(H)

Repeatability Error

≤125

±3

0.035`d

125˂HBW≤225±2.50.030`d
>225±20.025`d

H:Hardness of standard block `d:Indentation diameter(average)


Working Principle

Hardness is not a simple physical quantity, but a reflection of the material elasticity, plasticity, strength and toughness .and hardness test is the most simple mechanical testing method to determine the metal material performance. Also one of the important means to judge the products quality.

Brinell hardness test: Test force(F) is on the steel ball with certain diameter(D) , pressed on sample surface. After a period of time, cancel the force. The indentation diameter is get by measuring with micrometer ocular,thus to calculate the average pressure(N/mm²).Then we can get the Brinell hardness of the sample as below:

Tips:F—Test force on steel ball,unit:N

D—Diameter of steel ball ,unit:mm

d—Indentation diameter,unit:mm

0.102—Rule coefficient

Features

  • Suitable for measuring the surface is more rough cast iron, steel and other non-homogeneous specimen Brinell hardness;
  • The use of automatic closed-loop pressure sensor control system, can dynamically reflect the loading process load changes.
  • Modeling novel, strong structure,high reliability and operability , intuitive, high test efficiency;
  • Equipped with excellent performance of the carbide indenter, high hardness, wear resistance, good toughness, while high temperature, corrosion resistance, to ensure that the instrument measured standard, stable and reliable;
  • Support Brinell, Rockwell, Vickers and other hardness standard conversion;
  • LCD liquid crystal display screen , menu intelligence tips, easy to operate
  • Compliance with ISO 6506, ASTM E10-12, ASTM E-384, GB / T231.2, JIS Z2243 and other relevant domestic and foreign standards.

Brand reputation

The cetificate of CE,GOST,ISO9001 and etc..

Applied condition

  • Cast iron, steel, non-ferrous metals, soft alloy of metal material
  • Hard plastic, bakelite and some nonmetallic material.

Application field

  • Metal processing industry quality control links
  • Universities teaching and demonstration test
  • The failure test of metal material
  • The material hardness test of scientific research institutions

Working conditions

  • Working Temperature:18℃~28℃;
  • Relative Humidity:≤65%;
  • Clean environment, no vibration;
  • No corrosive media around.

Configuration

Standard

Configuration


No.ItemQuantityNote
1Main body1
220×Lens1
3φ2.5mm ball1
4φ5mm ball1
5φ10mm ball1
6Small testing table1Diameter 80mm
7Large testing table1Diameter 200mm
8V-shape testing table1For cylindrical sample
9

Standard Hardness Block

HBW/3000/10(150-250)

1
10

Standard Hardness Block

HBW/1000/10(75~125)

1
11

Standard Hardness Block

HBW/187.5/2.5(150-250)

1
12Fuse wire(2A)3
13RS232 Cable1
14Power line1
15Plastic dust cover1
16Attached files1
17Instrument case1
Optional Configuration1Brinell measurement system1

Maintenance and care

  • Each technical requirement of the instrument has already reached the national standards before leaving factory. But its disassembly, transportation or voltage after delivery might cause some data in the instrument changed. So to make the electronic component in normal operation to reduce the testing error, you can use test force of 29400N(3000kgf) pressing times before starting the instrument to eliminate the instrument deformation.
  • The anti-interference component has been installed in the circuit to ensure the transmission of the loading or unloading single of the test force at all levels. At the same time, make sure no strong interference source around when using the instrument, and power off the instrument after finished the testing.
  • All the screws and the caps have been fasten tightly before the instrument leaving factory. However, the screw and cap may become less crowded because that the screw lever for loading and unloading are rotating all the time. If there is irregular noise, when the screw lever rotating, please check and tightened the screw and cap as the below figure shown.

Pulley and cap


  • The instrument power supply shall be grounded reliably and equipped with voltage-stabilizing device;
  • If there is some slight noise during loading or unloading, it is the loading mechanism making adjustment automatically, which is a normal phenomenon.
  • The instrument screw level and other movable surface should be lubricated regular.
  • When not in use for a long time, please cover the dust cover to prevent dust into the instrument interior. And the hardness block, indenter should be coated with antirust oil to prevent rusting after using.
  • Start using again after long time idling, please make testing after preheating the electrical components.
  • The accuracy of the reading microscope has been adjusted before leaving factory. It is prohibited to disassembly without authorization. Otherwise, it will reduce the reading accuracy of the micro eyepiece.
  • The storage and using of the reading microscope should avoid dust, damp and corrosive gas environment;
  • If there is dirt on the surface of the reading microscope lens, please wipe it with soft absorbent cotton or lens paper. If there is oil pollution, please wipe it slightly by the absorbent cotton with industrial alcohol or ether.
  • Don’t disassemble the instrument without authorization, maintenance related matter, please contact MITECH after-sale service department with 4000600280.
China MITECH MHBS-3000 Accurate measurement Stable and reliable Digital Display Brinell Hardness Tester supplier

MITECH MHBS-3000 Accurate measurement Stable and reliable Digital Display Brinell Hardness Tester

Inquiry Cart 0