GC6891N Gas Chromatography


NameModelConfigurationQty

Gas

Chromatography


GC6891N

1. Detector: FID,TCD

2. Capillary and packed column injection system

3. 7 steps program heating

4. Smart backdoor

5. Chromatography workstation

6. EPC control

7. 6-way valve and 10-way valve


1

Hydrogen-air generator1
Liquid automatic sampler, 16 positions1

  1. Name

Gas Chromatography


  1. Model

GC6891N

  1. Instruction

GC6891N is a new generation of high-end laboratory GC,which is produced according to the international standards. Based on the most advanced international technical area and application experience, its features, reliability and sensitive application are in the world high level.

  1. Features

4.1 Injector flow, column carrier flow, detector gas flow are controlled by EPC.

4.1.1 Micro-channel gas integrated board

4.1.2 Imported micro-ratio and flow/pressure sensor

4.1.3 Temperature self-compensation to ensure the accurate flow, its pressure controlling can precise to 0.01Psi.


4.2 Industry-leading detector design.

4.2.1 All the detectors with high-precision electronic flow/pressure control.

4.2.2 It can be matched with packed column and capillary column.

4.2.3 The amplified board after special ceramics treatment can keep stable in wet season.


  1. It is safe and reliable with the functions of self-ignition and hydrogen leakage self-protection.

4.4 Accurate tracking design for furnace temperature.


4.5 Accurate programmed heating control for the furnace temperature.

4.5.1 Inner temperature controlling precision: <0.01

4.5.2 Temperature between inner points: ≤1℃

4.5.3 Quick heating and cooling, the max programmed heating speed: 120℃/min, balance time: 10 sec, cooling time: 300℃-50℃ for 6 minutes.

4.5.4 The temperature precision is absolutely controlled(compared with the real temperature, the difference is less than 0.3℃).


4.6 The achievement of gas circuit cutting technology

4.6.1 Complex samples separation can be analyzed by multidimensional chromatography.

4.6.2 It saves the analysis time and period by blowback function of the chromatograph column.


4.7 Chromatographic columns can be heated individually, and the using temperature can be set according to the different columns, so that make every column separately.


4.8 GC6891N adopts the advanced power distribution management shunt. One 3000-watt UPS can provide stable working power for 10 sets of GC with the normal power of 2250w/set.


4.9 GC6891N adopts the imported valve configuration system, which can carry 8 valves (4-way valve, 6-way valve, 10-way valve or liquid sampling valve) to automatically control and operate by sequence.


4.10 GC6891N uses 8-digit auto-injectors (you can choose Agilent 7683/7693 liquid auto-injector).


  1. Parameters
Column oven
Furnace dimensions28 x 30 x 18cm
Temperature controlling rangHigher than the room temperature of 5℃-450℃, liquid nitrogen cold trap: -80℃-400℃,dry ice cold trap:-55℃ to 400℃
Temperature setting precision0.1℃
Max programmed heating speed120℃/min
The longest method run time999.99 min
The highest step of program7 steps
Programmed heating rate0.1-120℃/min(increment of 0.1℃)
Column loss can be compensated (dual channel column)
Heating area
Six individual controlling heating areas (do not content furnace temperature control, two injectors, two detectors and two auxiliary heating areas ).
The maximum using temperature in auxiliary heating areas300℃
Detectors
FID
Maximum using temperature450℃
Minimum LOD:≤2.5pgC/s[n-C16]
Linear dynamic range107(±10%)
Data collection frequencyMax 100 Hz
Adapted to packed columns and capillary columns
TCD
Maximum using temperature400℃
Minimum LOD<400 pgC3H8/ml(He)
Linear dynamic range105(±5%)
Data collection frequencyMax 100 Hz
The design of monofilament TCD and micro-ECD, adapted to packed columns and capillary columns

  1. Application fields

GC6891N is widely used for the analysis of oil extraction and refining, petrochemical, fine chemical, food safety, environmental protection, electronic high-purity gas industry, scientific research institutes, QC, safety supervision, public security forensic and national security and so on.