Home /Pneumatic Components /

Material Burning Horizontal Flammability Tester , 220v Needle Flame Test Apparatus

Material Burning Horizontal Flammability Tester , 220v Needle Flame Test Apparatus

Brand Name:YUYANG
Certification:IEC60695-2-2, IEC60695-11-5, GB4706.1, GB5169.5
Model Number:YY314
Minimum Order Quantity:1 set
Delivery Time:5 work days
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China
Supplier`s last login times: within 25 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

IEC60695-2-2 Needle Flame Tester, Material Burning IEC60695-11-5 Testing Equipment


Description:


Needle Flame Tester is used to assess the fire hazard of such component materials. The test is performed to determine that the test flame does not cause ignition of parts, or that a combustible part ignited by the test flame has a limited duration of burning or a limited extent of burning, without spreading fire by flames or burning or glowing particles falling from the test specimen.

The Needle-Flame Tester is a fully automatic instrument contained in its own cabinet to maximize the safety of the operator. The Needle Flame Tester consists of a 0.9mm needle burner that tilts to 45° from the vertical and is fueled with butane gas. The test time for the temperature of the standard copper block to increase from 100° C ± 5° C to 700° C ± 3° C shall be 23, 5s ± 1, 0s. Test flame height is adjusted 12mm ± 1mm. Measuring the burning duration of the specimen, and any ignition of the wrapping tissue and white pine board below the specimen assesses the fire hazard of the specimen. It consists of a tube with a bore 0.5/font> 0.1mm and gas-flow regulating valve for adjustment of the flame height. It shall be used with a pressure regulator. The instrument is designed to conform to the IEC60695-11-5, IEC60695-2-2 and other most commonly used standards in the market.


Features:


1, The character of test equipment: burning box and the main mechanical parts is made of stainless steel what is good looking, smoke resistance corrosion. The Control system has a higher degree automation, imported key components , digital time, three-dimensional adjustable fixture, automatic control of test procedures, independent ventilation, easily used observation and recording, stable and reliable.
2, test box shell and important parts is made of stainless steel, smoke resistant, gas corrosion. The control system has a high degree of automation and automatic ignition function. Temperature and time are digital displayed, easy to observe and record. The control system is stable and reliable.


Advantages:


1. Can meet different test methods and standards, GB,ISO,ASTM test methods setting freely.

2. LCD display all the test result, data and curve.

3. Wrapping connector driving system to make working more stably and more precision.

4. Microcomputer controlling, all keyboard operation.

5. Automatic judgment materials slide adhesive state and sample test results between quantitative discrete analysis.

6. Static friction coefficient and dynamic friction coefficient option freely, flexible test.

7. Can save 6 test results and data and display the curve. Also with query function.


Standard:


GB4706.1-1998

GB5169.5-2008

IEC60695-2-2

IEC60695-11-5


Specification:


Needle burner

Inner hole diameter Φ 0.5mm ± 0.1mm, Diameter,9mm≤Φ,

length ≥ 35mm, stainless steel

Burner angle

0,°20°, 45° (adjust flame height)

Thermocouple

Ø0.5mm Type K (Ni/Cr - Ni/Al), armored sheath can withstand

temperature-40°C~ 1100°C

Burning time

0-999.9 s ± 0.1 s adjustable (usually selected for 30s)

Hold Burning time

0-999.9 s ± 0.1 s, automatic recording, manual time-out

Flame Height

12mm ± 1mm (with height measurement instruments)

Flame Gas

Butane gas/Butane gas, min. 95% purity (can use bottled lighter gases)

Temperature Test Range

0~1000°C

Flame Temp Requirements

From 100 °C ± 2 °C liters to 700 °C ± 3 °C time in 23.5 seconds ± 1 seconds

Standard Copper Block

4mm±0.01mm, weight.0.58g±0.01g before drilling. Cu-ETP

Test process

Automatic control, independent convulsions

Chamber

≥0.5m3

Control

Using single chip microcomputer + touch screen control

Consult standard

GB/T5169.10-2006, IEC60695-11-5: 2000,UL746A

Power Supply

800VA, 220V, 48-60Hz

Display panel language

English (customize available)


Experimental principle:


Needle flame tester burns the test sample In a 45 °angle direction timingly by using a specified size (Φ0.9mm) needle-like burner which have a specific gas (butane). The dangerous assessment of the small flames caused by the failure conditions within the equipment depends on whether the test product ignites and the ignition time and the length of the combustion.





China Material Burning Horizontal Flammability Tester , 220v Needle Flame Test Apparatus supplier

Material Burning Horizontal Flammability Tester , 220v Needle Flame Test Apparatus

Inquiry Cart 0