Home /Vacuum Equipment Parts /

Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment

Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment

Brand Name:YUYANG
Certification:ISO
Model Number:PMCC-B
Minimum Order Quantity:1 Set
Delivery Time:15 days
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: B1505, FORTUNE PLAZA, No.1, Yuanmei Road, Nancheng District, Dongguan City, Guangdong Province, China
Supplier`s last login times: within 25 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details
Manual Pensky-Martens Closed-Cup Flash Point Apparatus
Summary
Cheap Manual Pensky-Martens Closed-Cup Flash Point Apparatus is designed and manufactured as per standards GB/T 261-2008 Determination of Flash Point - Pensky-Martens Closed Cup Method and ASTM D93 Standard Test Method for Flash Point by Pensky-Martens Closed Cup Tester. It is used to make determination of the closed cup flash point of the petroleum products.
I. Main technical features
1. Manual Pensky-Martens Closed-Cup Flash Point Apparatus is designed as per GB/T261 and ASTM D93.
2. The heating power is continuously adjustable. The power is shown visually by voltmeter.The temperature control mode is advanced and reasonable.
3. The structure is designed small and exquisite.The stainless-steel table board is beautiful and easy to clean.
4. Operation is easy.Test results are precise.It has been chosen as the instrument to test the closed cup flash point by many metering and detecting institutes.
II. Main technical specifications
1. Power supply:AC (220±10%)V, 50Hz.
2. Heating device::The heating power is continuously adjustable from 0 W to 600W.
3. Heating rate::(1~12)℃/min;Controllable and adjustable.
4. Stirring rate: Procedure A: (90~120)RPM, Procedure B: (250±10)RPM
5. Oil cup:(1) Inner diameter: 50.7mm~50.8mm.
(2) Depth: 55.7mm~56.0mm
(3) The scribed line depth of capacity of testing oil: 33.9mm~34.3mm.
(4) Capacity of testing oil:about 70ml
6. Igniting device:(1) Igniting source: gas(or other civilian fuels,the same below)
(2) Electric ignition. Gas flame diameter:3.2mm~4.8mm
7. Thermometers:Mercury-in-glass thermometer.Specifications are as below:
(1)Scale -5℃~110℃, division 0.5℃.
(2)Scale 20℃~150℃, division 1℃.
(3)Scale 90℃~370℃,division 2℃.
8. Ambient temperature:≤ 35℃
9. Relative humidity:≤ 85%
10. Maximum power consumption:650W
III.Accessories
No.ItemUnitQtyRemarks
1Thermometer -5 ~ 110 ℃, each scale division is 0.5 ℃Piece1

GB / T261-2008

Standard requirement

2Thermometer 20 ~ 150 ℃, each scale division is 1.0 ℃Piece1
3Thermometer 90 ~ 370 ℃, each scale division is 2 ℃Piece1
4Driving flexible shaftPiece1
5Latex tube Ф3 250mmPiece3One for alternate
65A fuse (Ф5 × 20)Piece2
7Thermometer adapterSet1
8

Thermometer liner

(Cut suitable length of liner to wrap the lower end of the thermometer, so that the thermometer is just inserted into the thermometer adaptor)

Piece5
China Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment supplier

Manual Pensky Martens Closed Cup Flash Point Analyzer / Oil Testing Equipment

Inquiry Cart 0