Original and new drager medical Oxygen sensor 6850645 for Ventilator 6850645 O2 sensor O2 cell


Sensor Specifications & Compatibility
Catalog Number
Output Signal in Air24A - 32A (Dual Cathode) no temperature compensation
Response Time T 90%< 12 seconds
Nominal Sensor Lifetime500 000 % volume Oxygen hours
Electrical InterfaceGold plated slip rings
Compatibility:Draeger 6850645 (Dr¤ger)
Babylog, Fabian, Cicero, PM8030
Evita, Oxydig, Anemone, Oxycom
Incubator 8000
M08 ST13
MAX11
Invivo Magnitude
10-103-07
PT14A
Teledyne R13 C-61139
Hudson 5557 (V14)
VTI 101372, 100352
* Note: Order E61720 with reusable cap and "o" rings
Medical Oxygen Sensors (Fuel Cells) general specifications:
Measurement Range:0-100 % oxygen
Accuracy and Repeatability:< 1 % vol. O2when calibrated at 100 % O2
Zero Ofset:< 0.5 % vol. O2in 100% N2, applied 5 minutes
Linearity Error:< 3 % relative
Cross Interference:< 0.5 % vol. O2response to:
10 % CO2balance N2
80% N2O balance N2
7.5% Halothane balance N2
7.5 % Isofurane balance N2
7.5 % Enfurane balance N2
9% Sevofurane balance N2
20% Desfurane balance N2
Infuence of Humidity:- 0.03 % rel. per % RH at 25C
Infuence of Pressure:proportional to change in oxygen partial
pressure
Infuence of Mechanical Shock:< 1% relative after a fall from 1m
Operating Temperature:0 to 50C
Temperature Compensation:built-in NTC compensation (see below)
Efect of Temperaturebetween +5 C and +25 C: 3 % relative error
Compensation (steady state):between 0 C and +50 C: 8 % relative error
Operating Humidity:0-99 % RH non-condensing
Long Term Output Drift:< 1 % vol oxygen per month
typically < - 15 % relative over lifetime
Storage Temperature:-20 to +50 C
Recommended Storage:+5 to +15 C
Recommended Load:10 kOhms
Warm-Up Time:< 30 minutes, after replacement of sensor
Weight:approximately 28 grams
approximately 43 grams E61912 series
Designed and manufactured according to EN ISO 9001 : 2000 and EN13485 : 2003
specifications are applicable at standard conditions: 1013 hPa, 25C dry ambient air
Oxygen sensor for Draeger OEM 6850645