Home /

Stranded Copper Conductor Medium Voltage Underground Cable 3.6/6 KV

Stranded Copper Conductor Medium Voltage Underground Cable 3.6/6 KV

Brand Name:Chengtiantai
Certification:CE, ISO, IEC
Minimum Order Quantity:500 m
Delivery Time:7/15 working days
Payment Terms:L/C, T/T
Place of Origin:Shenzhen, China (mainland)
Contact Now

Add to Cart

Verified Supplier
Location: Shenzhen Guangdong China
Address: Chengtiantai industry park, Bahang road, Lisonglang community, Gongming block, Guangming district, Shenzhen city, Guangdong province, China.
Supplier`s last login times: within 48 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

3,6/ 6 (7.2) kV Copper conductor XLPE (Cross-linked Polyethylene) Insulated PVC Sheathed power cable


stranded copper conductor - conductor screen of semiconducting compound - XLPE insulation - core screen of semiconducting compound - copper tape screen - separation tape - PVC sheath


suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground as well as for installation on cable trays for industries, switchboards and power stations.


STANDER

International:IEC60502-2

National:GB/T 12706.1-2008

CONSTRUCTION:

1. CONDUCTOR

– Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

2. CONDUCTOR SCREEN

– Inner semi-conducting coating

3. INSULATION

– Core insulation of cross-linked polyethylene (XLPE)

4. INSULATION SCREEN

– Outer conductive layer extruded and per-manently welded with the core insulation

Semi-conducting type
– Over the outer semi-conducting layer, a semiconducting tape must be used.

5. METAL SCREEN

– copper tapes helically with a minimum thickness of 0,1 mm.

Separator
– Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

6. SHEATH

– Outer sheath of PVC compound

CHARACTERISTICS


Construction characteristics

Conductor shapeCircular stranded (RM)
Lead freeYes
InsulationXLPE
Screencopper tape
Material of beddingSeparation tape
Outer sheathPVC
DIMENSIONAL CHARACTERISTICS
Number of cores1& 3 core
ELECTRICAL CHARACTERISTICS
Nominal Voltage Uo/U3,6 / 6 kV
Operating Voltage (Um)7,2 kV
Testing Voltage12.5 kV (5 Min)
Usage characteristics
PackagingSteel Wooden Drum
Minimum installation temperature-20 °C
Max. conductor temperature in service90 °C
Short-circuit max. conductor temperature250 °C
Bending factor when laying

20 x D single core cable

15 x D multi-core cable


3,6/ 6 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed


nominal cross sectionOperation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
mm²kVkVmmmmmmkg / kmAAΩ/km
357.23.6 / 62.51.618.46162051900.52
507.23.6 / 62.51.719.97882452250.39
707.23.6 / 62.51.7219993052750.27
957.23.6 / 62.51.823.512763703300.19
1207.23.6 / 62.51.824.915324303750.15
1507.23.6 / 62.51.926.718494904250.12
1857.23.6 / 62.51.928.321975604800.10
2407.23.6 / 62.62.030.727636655550.08
3007.23.6 / 62.82.133.733917656300.06
4007.23.6 / 63.02.238.944338907250.05
5007.23.6 / 63.22.342.2547410308250.04
6307.23.6 / 63.22.445.6675111909400.03

3,6/ 6 kV XLPE Insulated, Copper conductor, 3 cores, screened, PVC sheathed


No. of coresnominal cross sectionOperation
voltage
max.
Nominal
voltage
U0/U
Insulation
thickness
Sheath
thickness
Nominal
value
Outer Ø
approx.
weight
approx.
Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
No.mm²kVkVmmmmmmkg / kmAAΩ/km
3357.23.6 / 62.52.238.520731421850.52
3507.23.6 / 62.52.341.526141692160.39
3707.23.6 / 62.52.444.333172102640.27
3957.23.6 / 62.52.549.341832573160.19
31207.23.6 / 62.52.652.550142983600.15
31507.23.6 / 62.52.756.160003364020.12
31857.23.6 / 62.52.859.871543934610.10
32407.23.6 / 62.63.064.989254635330.08
33007.23.6 / 62.83.271.3109375265990.06
34007.23.6 / 63.03.580.3142146056800.05


*Dimensions and specifications may be changed without prior notice.


MEDIUM VOLTAGE CABLE TESTING


Routine tests:Sample tests:Type tests:
These non-destructive tests are normally carried out on all lengths manufactured.
- Conductor resistivity
- Spark test on oversheath
- Voltage tests on sheath
- D.C. voltage test on oversheath
These potentially destructive tests are normally carried out on every production run.
- Examination of conductor and dimensions
- Hot set test for XLPE insulation
- Insulation and oversheath thickness
- Four hour voltage test
These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
- Electrical type tests including bending and heat cycle
- Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

PACKING AND SHIPPING


Packing: steel wooden drum, other as required ; standard delivery length is 300 m


Packaging & Delivery

Packaging details :

Delivery :

Steel Wooden DrumsCable Drum In containershipped in 15 days after payment

Cable Drum Data


CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
1000700500
1100700550
1200700600
1400750710
1600900900
180011201000
240011501300

Delivery Port:


Port of ShenzhenPort of HongkongPort of Guangzhou

Our production in numbers


● Cable production started 1983
35 years of cable manufacturing experience

● Sales in 2016 about 500 million USD

100,000 m2 Production area
350 Will-trained employees
● Exported more than 22 countries
2 Manufacturing plant
1 R&D Center

200 Sets Of Testing Equipment

100 Testing Items
8 workshop
40 wire drawing machines
10 bunching machines
28 Extruder system
42 stranding machines
10 Braiding machines

Shenzhen chengtiantai cable operates certified management systems compliant with:
CertificatInformation
ISO 9001:2008
Quality management systems

Certificat ISO 9001:2008
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 9th January 2022
ISO 14001:2004
Environmental management systems

Certificat ISO 14001:2004

- Shenzhen chengtiantai cable industry development Co.Ltd. ;

Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

Valid until 9th January 2022

OHSAS 18001:2007
Assessment specification for occupational health & safety management systemsenvironmental management systems
Certificat OHSAS 18001:2007
- Shenzhen chengtiantai cable industry development Co.Ltd. ;
Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
Valid until 9th January 2022

Manufacturing Process Of Medium Voltage Power Cable

1. copper rod2. wire drawing3. wire stranding
4.Triple Extrusion Insulation5.Screening Process6. outer covering Process
7. Sheath Marking8. Packing9. Partial discharge Inspection

Some great shot on our manufacturing plant


Located in: Chengtiantai Industrial Park, Guangming New District, Shen zhen P. R. China 518106

Customer services:


RECOMMENDED ORDERING PARAMETERS

CONTACT

For prompt quotation / supplies please make sure your inquiries and your orders are
securing the following data :

1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
2 - Rated voltage.
3 - Copper or Aluminium conductors.
4 - Size of each conductor.
5 - Insulation material : XLPE or others.
6 - Number and identification of conductors.
7 - Other requirements.
8 - Packing.
9 - Required delivery time.
10 - Required validity.

If this all seems a litle too technical for you, then why not get in touch with us.


We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.


Tel:+86 755 6114 5028
Fax:+86 755 61137976
E-mail : cttcable@hotmail.com
Head office:chengtiantai Industrial Park, Lisonglang community, Gongming office, Guangming district, Shenzhen P.R. China 518106


WARRANTY


For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

China Stranded Copper Conductor Medium Voltage Underground Cable 3.6/6 KV supplier

Stranded Copper Conductor Medium Voltage Underground Cable 3.6/6 KV

Inquiry Cart 0