Ce ISO Hospital Clinic Medical Portable Enteral Feeding Infusion Pump


We can offer

1. Factory directly price

2. Nice quality

3. Quick shipping within 7-10 days

4. Small order welcome

5. Payment by e-Checking, Credit Card or Bank Transfer, we accept Alibaba Trade Assurance order which will offer you 100% Product quality protection ,100% On-time shipment protection and 100% Payment protection.


Technique Parameters:

a) Infusion rate:0ml~999ml,≤±10%

b) Total volume:0.1ml~999ml,≤±10%

c) flow rate:1ml/h~300ml/h;

d) Infusion accuracy:At 1ml/h~50ml/h,range:1ml/h,≤±10%;

At 50ml/h~300ml/h,range 5ml/h,≤±10%

e) Power consumption:13VA

f) Size: 193mm×130mm×105mm

g) N.W:1.6kg

h) Feeding tube:Special feeding tube


Working Conditions:

a) Ambient temperature:5℃~40℃;

b) Relative humidity:30%~80%;

c) Barometric:860~1060hPa;

d) Power supply:AC220V,50Hz

e) Battery:Ni-H2 battery group 9.6V,1600mAh


Alarm function:Sound and light alarm as following situations

a) Without any operating when switched on

b) when reach reques volume

c)low battery

d)Feeding tube is in empty,blocked and folding

e) When working loss of AC supply suddenly


Control Panel and Instruction of Operation


Install

a) Hanging the infusion bag(bottle) on infusion support, and connect tube on infusion bag, Flat the pump on the desktop. The desk is under the infusion bag. Turn on tubes switch( FIG 1.).The nutrient fills the tube, the nutrient must not exceed the level line.

b) Install the tube into the pump as (FIG2 )

FIG 1 FIG 2

c) Turn ON the switch, Pressto set the rate

d) Pressto drain the gas in tube, then connect the tubes with patient’s catheter

e) Press,Pump begin delivery nutrient to stomach

Trouble shooting

ProblemPossible CausesWhat To Do
Alarm Continue

1)Liquid above line in “venture” catheter”

2)Bodies block monitoring port

1)Lowering water 2)removal the bodies(Maybe water droplets in monitoring, can swing tube)
Interrupt alarmPump in forward or backward placePut in flat place
After starting pump, not rotate and interrupt light onPump wheel is stuck by nutritiousUnscrew pump wheel and clean it.
When pump intermittent stall, “venturi catheter” is still drippingThe tube is too long or joint is slide out from position1)Choose special feed tube.2)recovery joint in original position
Flow rate is inaccurateDidn't use special feeding tubeUse special feeding tube