Home /Energy Meters /

Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing

Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing

Brand Name:GFUVE
Certification:IEC61000-4-30 CLASS A
Model Number:GF438II
Minimum Order Quantity:3set
Delivery Time:3-7days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Beijing Beijing China
Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China
Supplier`s last login times: within 37 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

GF438II GFUVE IEC 61000-4-30 CLASS A Three Phase Power Quality Analyzer With flicker & 63rd harmonics


GFUVE GF438II class A power quality analyzers can help you discover the state of health of your power systems. Designed to meet the needs to the intended measurement task, power quality analyzers help you beprepared for any power quality issues.The Power Quality analyzers that can monetize the cost of energy waste due to poor power quality. More powerful sampling options, greater accuracy and larger memory makes the GF438II better for longer term, higher resolution or more demanding power quality studies.

Class A power quality (PQ) analyzers are used for this per IEC 61000-4-30. The regular testing and calibration of these devices has presented manufacturers, commissioners and equipment maintenance personnel with new challenges. For instance, the standard IEC 62586 requires different PQ parameters to be swapped during extensive type tests.

GF438II handheld three phase power quality analyzer offer the best ability in power quality analysis, GF438II handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.

Power Quality Analysers. Power Quality Analysers are powerful and versatile instruments available to the modern electrician and electrical engineer. Our complete range of Class A and Class S Power Quality Analysers can be used for diagnosing Power Quality problems, Energy Load Profiling and for producing Harmonic Surveys of an electrical installation.


The GFUVE GF438II power quality analyzers are designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime.

  • Measure multiple parameters simultaneously to quickly understand overall power quality health
  • View data as simple digital values or more detailed trend graphs that give you fast insight into changes over time, waveforms, and phasor diagrams
  • Organize data in tabular format so you can quickly correlate parameters like magnitude, duration, and time to the issues you are experiencing in your facility

APPLICATION

Electrical Power Systems
Power Plants
Photovoltaic
Distribution


Industrial Systems
LV Installations Safety / Quality
UPS Systems testing
Switchboards / Controlgears
Machines / Power Loads
Electrical Equipment / Appliances
Maintenance / Troubleshooting
3-phase system testing
High level industrial testing
Mid level industrial testing


Buildings Facility Management
Public areas Safety / Quality
Voltage Quality / Power Loads


Special Installations / Locations
Construction Sites
Railway Systems
Ships / Boats / Marina Places
Fire Brigade Vehicles
Military / Police Vehicles
Mobile LV Generator Units
Medical Sites / Surgery Rooms
Laboratory use
Service / Repair / Rental Offices
Electric motors testing

FEATURES

  • 3s statistical interval, continuously record 168h
  • Support multi-brand current transformer
  • Up to 32G data storage space
  • Record up to 461 power energy parameters simultaneously
  • Up to 10000 screenshots saved
  • Support periodic recording function
  • Up to 3.9M/s USB high-speed transfer
  • Recording wave

FUNCTIONS

  • Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
  • Power inverter efficiency: simultaneously measure AC output power for power electronics systems.
  • Power wave data capture: GF438II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
  • Waveform capture: GF438II capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up
  • Automatic transient GF438II analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V.
  • Fully class-A compliant: GF438II analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard.
  • Mains signaling: GF438II analyzer measure interference from ripple control signals at specific frequencies.
  • Troubleshoot: analyze the trends using the cursors and zoom tools.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
  • Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
  • Automatic trending: every measurement is always automatically recorded, without any set-up.
  • System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard
  • Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals.
  • View graphs and generate reports: with included analysis software.
  • Battery life: up to 5 hours operating time per charge on Li-ion battery pack.

PARAMETERS

NameMeasurement type
Voltagerms, ava, pk+, pk-, rms-1/2, CF
FrequencyFreq
Currentrms, ava, pk+, pk-, rms-1/2, CF
Power & energyP, S, Q, PF, DPF, W
ComputationTHD, DC, 1-63 Harm, 1-62 InHarm, 1-35 HiHarm, 1-62 SubHarm
Voltage harmonicTHD, DC, 1-63 Harm, 0-62 InHarm, 1-35 HiHarm, 1-62 SubHarm , KF
Current harmonicTHD, DC, 1-62 Harm
Harmonic powerIa, Ib, Ic, ΣPtotal, ΣQtotal, ΣStotal, 15 minutes
Fluctuation and flickeringPST, PLT, Fluct, Fluct Max
UnbalV Pos, A pos , V neg , A neg , V zero, A zero, Unbal
Event logVoltage swell, voltage sags, DIP, surge current, voltage and current
distortion out of limit, odd harmonics containing rate out of
limited, unbalanced voltage current out of limit, frequency out of limit, PST out of limit, PLT out of limit, long-term voltage interruption, voltage fluctuation deviation, voltage harmonics out of
limit, 2-25st harmonicsout of limit
P, Q, S nameMeasurement type
Measurement typesP: Calculate by every 10 cycles
S: Calculated by the effective value of voltage and current
Q: Calculated by the apparent power, active power
DisplayTable charts, trend chart
Measuring rangeAccording to the range of the voltage and current
Resolution0.001W
Accuracy±0.5%
UrmsMeasurement type
Mode'Calculated by the square root value of 10/12 cycle
Measuring circuit1P2W/ 2P3W /3P3W/ 3P4W
Basic frequency of the measuring circuit50Hz, 60Hz
Input channels4 phase voltage, 4 phase current
Display modeEffective current value of each channel
Range120V, 230V, 400V, 1000V, Max 1000V instantaneous voltage
Resolution0.001V
Accuracy0.1% RG
ArmsMeasurement type
Mode'Calculated by the square root value of 10/12 cycle
Display modeEffective current value of each channel
RangeCurrent: according to the current clamps
Option Current clamps:5A/50A/100A/500A/1000A
Flexible Current probe: 1000A/3000A/6000A
Resolution0.001A
Accuracy0.1% + accuracy of the current clamps
FrequencyMeasurement type
Measurement modeCalculate by 10 cycles (50Hz) or (60Hz)
Display modeMeasurement by 10 cycles
Nominal frequency/resolution50.000Hz/0.001Hz or 60.000Hz/0.001Hz
Bandwidth measurement42.5-57.5Hz or 52.5-67.5Hz
Accuracy±0.001Hz
Half-wave RMS current/voltageMeasurement type
Measurement modeCalculate by every 2 cycles. Each cycle ,1/2 cycle made up of a
waveform calculation
Measuring range/resolutionVoltage: 120V/0.01V, 230V/0.01V, 400V/0.01V, 1000V/0.01V,
Current: According to the current clamps
measurement accuracy±0.1%
Power factorMeasurement type
Measurement modeThe ratio of average power to apparent power
Display modeReal-time data showed
Measurement range/resolution-1.000-1.000/0.001
Accuracy±0.1%
Vfund, Afund, Harmonic powerMeasurement type
Measurement modeMeet IEC61000-4-7,Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Number of measurement1-50 Times
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
InHarm Voltage, InHarm currentMeasurement type
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points
Display modeForm figure, trend charts, histograms
Numbers of measurement1-16 groups
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range
HiHarm Voltage, HiHarm currentMeasurement type
Measurement modeMeet IEC61000-4-7, Analysis time window is ten cycles
Window points5120 points every 10 cycles
Display modeForm figure, trend charts, histograms
Numbers of measurement1-35 groups/2100Hz-8900Hz
Measurement accuracyVfund >1%: Error<1%
Vfund <1%: Error<0.05% Rated Voltage
Afund >3%: Error<1%
Afund <3%: Error<0.05% Current range

Photo


China Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing supplier

Class A Three Phase Power Quality Analyzer With Flicker 63rd Harmonics For Electric Motors Testing

Inquiry Cart 0