Home /Flow Meters /

Fixed Inline Ultrasonic Flow Meter 85 - 265V AC For Heating And Cooling Supply

Fixed Inline Ultrasonic Flow Meter 85 - 265V AC For Heating And Cooling Supply

Brand Name:Iflow
Certification:ISO9001, CE
Model Number:TUF2000S
Minimum Order Quantity:negotiable
Delivery Time:1-2 weeks
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
Supplier`s last login times: within 32 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Fixed inline Ultrasonic Flow Meters for municipal heat & cooling supply | water supply


Transit time ultrasonic flow meter

When use the transit time ultrasonic flowmeters, be sure that the fluid can adequately conduct ultrasonic waves, because the flowmeter will not measure when the ultrasonic waves cannot penetrate the flow stream between the transducers. Similarly, ultrasonic waves must be able to penetrate the fluid for Doppler flowmeters to operate accurately. When the fluid is relatively opaque and does not penetrate the fluid, Doppler flowmeters tend to measure the velocity of the fluid at or near the pipe wall, which can cause significant measurement error and/or cause the flowmeter to fail.


General description

The transit time ultrasonic flowmeter is used for volumetric flow measurement which hase no moving parts. Ultrasonic flowmeters are ideal for the wastewater applications or any dirty liquid which is conductive or water based. Ultrasonic flowmeters are also ideal for applications where low pressure drop, chemical compatibility, and low maintenance are required.

  • Independant of conductivity, viscosity, temperature, density and pressure
  • No moving or intruding parts, therefore no pressure loss or wear
  • Minimal operational and maintenance costs
  • Excellent long-term stability and reliability

Data sheet

ItemsPerformance & Parameter
ConvertorPrincipleTransit-time ultrasonic flow meter
Accuracy+ 1%
Operation4 keyboards operation
Output signal1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
1 channel relay output
Input signal3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
Temperature transducer Pt100, heat / energy measurement
CommunicationGalvanic isolation RS485, software upgrade by PC, MODBUS
Signal cableTwisted-pair cable, 50m; RS485, transmission distance 1000m or above.
Connect portPipe materialSteel, stainless, cast iron, copper, cement, PVC, aluminum, etc
Pipe Dia15 - 6000 mm
Straight pipeUpstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
MeteringLiquid type

Single sonic wave transmittable liquid, such as municipal water, cooling water, seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,

Temperature-30-160℃
TurbidityUp to 10000 ppm and less bubble
Flow velocity0-7 m/s
Work environmentTemperatureConvertor: -20-60 ℃, Transducer: -30-160℃
HumidityConvertor: 85%RH, Transducer: submersible up to depth 2m
Power supplyDC8-36V or AC10-30V / 1.5W
DimensionConvertor: 95*95*35mm

Work principle:

The pipe type inline ultrasonic flowmeter is a precision instrument designed for linear, bi/directional volumetric flow

measurement of liquids. Flow measurement values can be output via the standard analog and-or pulse/frequency

outputs. Through a user friendly operator interface (HMI) the unit can be set up for a wide range of applications.

Next to actual volumetric flow measurement the unit can be configuredto perform flow totalization (plus, minus and

sum). Also measurement and output of the liquid sonic velocity can be configured. Optionally the unit can be set to

perform one of the following additional functions:

  • Calculate and output corrected standard volumetric or mass flow using external pressure & temperature inputs
  • Batch function
  • Heat function, combining T1, T2 and volume

Metering Diagram

Flow measurement Heat measurement

Reference chart

TypeModelPipe dia (mm)TemperatureDimension (mm)
Clamp onTS-2DN15-100-30-90℃45x25x32
TM-1DN50-700-30-90℃64x39x44
TL-1DN300-6000-30-90℃97x54x53
Clamp on (high temperature)TS-2-HTDN15-100-30-90℃45x25x32
TM-1-HTDN50-700-30-90℃64x39x44
TL-1-HTDN300-6000-30-90℃97x54x53
Insertion typeTC-1DN80-6000-30-90℃190x80x55
TC-2(lengthen)DN80-6000-30-90℃335x80x55
Pipe typeG3 (π type)DN15-25-30-160℃
G2DN32/DN40-30-160℃
G3DN50-6000-30-160℃

Optional temperature transducer

SpecificationModelDiaTemp.Water cutAccuracy
Clamp-on temp. transducer Pt100CT-1>DN50-40-160℃No100+ 0.8℃
Insertion temp. Transducer Pt100TCT-1Yes
Insertion temp. Pt100 with pressurePCT-1No
Insertion temp.Pt100 for small pipe DSCT-1<DN50Yes

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

IModel
YFElectromagnetic flowmeter
TFTurbine
VFVotex
LXVane wheel
TUltrasonic
E/F display modeE: compact/local display, F: remote display
Pipe DiaType (mm)
xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000

CodeAccuracy
1+ 0.5% FS
2+ 1.0% FS
3+ 0.2% FS
CodeType
NConverter: 12 / 24 VDC, pulse output
ATransmitter: 24VDC, 4-20mA outpt
BIntelligent, Lion battery, no local display
GSmart, local display, 4-20mA output
C1Smart, local display, RS485
C2Smart, local display, HART
CodeType
SCarbon steel housing
LStainless steel housing
GHigh pressure housing
HL316L electrode
HTiTitanium electrode
HTaTantlum electrode
HCHastelloy-C electrode
L1Liquid media
L2Gas media
PPressure compensation
TTemperature compensation
PTPressure&Temp. Compensation
FPTFE liner
XRubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner


Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team
China Fixed Inline Ultrasonic Flow Meter 85 - 265V AC For Heating And Cooling Supply supplier

Fixed Inline Ultrasonic Flow Meter 85 - 265V AC For Heating And Cooling Supply

Inquiry Cart 0