Home /Water Treatment /

Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

Brand Name:Iflow
Certification:ISO9001, CE
Model Number:TUF2000B
Minimum Order Quantity:negotiable
Delivery Time:1-2 weeks
Payment Terms:T/T, L/C, Western Union
Contact Now

Add to Cart

Active Member
Location: Shanghai Shanghai China
Address: Room 811-Building 143, No. 1399 Husong Road, Shanghai, China
Supplier`s last login times: within 32 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment


Principle of operation

This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.


Data sheet

ItemsPerformance & Parameter
ConvertorPrincipleTransit-time ultrasonic flow meter
Accuracy+ 1%
Operation4 keyboards operation
Output signal1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
1 channel relay output
Input signal3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
Temperature transducer Pt100, heat / energy measurement
CommunicationGalvanic isolation RS485, software upgrade by PC, MODBUS
Signal cableTwisted-pair cable, 50m; RS485, transmission distance 1000m or above.
Connect portPipe materialSteel, stainless, cast iron, copper, cement, PVC, aluminum, etc
Pipe Dia15 - 6000 mm
Straight pipeUpstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
MeteringLiquid type

Single sonic wave transmittable liquid, such as municipal water, cooling

water,

seawater water, waste water, pure water, Sewage with particle content, such

as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

heating, ventilation ,air conditioner, power plants,

Temperature-30-160℃
TurbidityUp to 10000 ppm and less bubble
Flow velocity0-7 m/s
Work environmentTemperatureConvertor: -20-60 ℃, Transducer: -30-160℃
HumidityConvertor: 85%RH, Transducer: submersible up to depth 2m
Power supplyDC8-36V or AC10-30V / 1.5W
DimensionConvertor: 95*95*35mm

Features:

  • Non-Intrusive, transducer for Most Pipes from DN32 to DN6000mm
  • Inline pipe type , insertion type or clamp on probe transducer for options
  • Wide Measuring Range of 0.05 to 9 mps
  • ±2% of Calibrated Span Accuracy
  • Configuration and Total Stored in SD
  • Protection IP65 for housing, IP68 for transducer

Metering Diagram

Flow measurement Heat measurement

Reference chart

TypeModelPipe dia (mm)TemperatureDimension (mm)
Clamp onTS-2DN15-100-30-90℃45x25x32
TM-1DN50-700-30-90℃64x39x44
TL-1DN300-6000-30-90℃97x54x53
Clamp on (high temperature)TS-2-HTDN15-100-30-90℃45x25x32
TM-1-HTDN50-700-30-90℃64x39x44
TL-1-HTDN300-6000-30-90℃97x54x53
Insertion typeTC-1DN80-6000-30-90℃190x80x55
TC-2(lengthen)DN80-6000-30-90℃335x80x55
Pipe typeG3 (π type)DN15-25-30-160℃
G2DN32/DN40-30-160℃
G3DN50-6000-30-160℃

Optional temperature transducer

SpecificationModelDiaTemp.Water cutAccuracy
Clamp-on temp. transducer Pt100CT-1>DN50-40-160℃No100+ 0.8℃
Insertion temp. Transducer Pt100TCT-1Yes
Insertion temp. Pt100 with pressurePCT-1No
Insertion temp.Pt100 for small pipe DSCT-1<DN50Yes

Industries

  • Chemicals
  • Petrochemicals
  • Oil & Gas
  • Heating, Ventilation & Air Conditioning (HVAC)
  • Power Plants
  • Water treatment

Applications

  • Metering of cooling water
  • Demineralisedwater
  • Control of batching and blending operations
  • Mass flow measurement
  • Allocation measurement
  • District heating
  • Irrigation
  • Energy measurement

Model Selection

IModel
YFElectromagnetic flowmeter
TFTurbine
VFVotex
LXVane wheel
TUltrasonic
E/F display modeE: compact/local display, F: remote display
Pipe DiaType (mm)
xxxx

10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

400, 500, 600, 800, 1000

CodeAccuracy
1+ 0.5% FS
2+ 1.0% FS
3+ 0.2% FS
CodeType
NConverter: 12 / 24 VDC, pulse output
ATransmitter: 24VDC, 4-20mA outpt
BIntelligent, Lion battery, no local display
GSmart, local display, 4-20mA output
C1Smart, local display, RS485
C2Smart, local display, HART
CodeType
SCarbon steel housing
LStainless steel housing
GHigh pressure housing
HL316L electrode
HTiTitanium electrode
HTaTantlum electrode
HCHastelloy-C electrode
L1Liquid media
L2Gas media
PPressure compensation
TTemperature compensation
PTPressure&Temp. Compensation
FPTFE liner
XRubber liner

Sample: IYF-E-0100-1-C1-S-HL-L1-F,

Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

RS485, 316L electrode, liquid media meter, PTFE liner


Competitive Advantage:

  • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
  • CE approval
  • Strict process control
  • Advanced calibration equipment
  • Engineer team
China Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment supplier