Product Details
Wireless remote reading, prepaid water meter multi jet dry dial |
valve control, DN15 - DN25 Iron housing
Using method
The wireless remote meter-reading water meter system consists of
wireless remote water meter, collector, concentrator and management
software.
1. Bottom layer communication: Bottom layer communication means
communication between the collector and water meter. Wireless
network signal, has the positive of wide signal propagation, wide
coverage area ability, fast construction.
2. Middle layer communication: Middle layer communication means the
communication between the concentrator and collector. This
communication is by wireless RF way, no need of communication line.
The wireless communication distance between the concentrator and
collector can be about 3km at open environment. Each piece of
concentrator can manage 255 pieces of collector maximumly.
3. Upper layer communication: Communication methods indicate below
can be selected between concentrator and management center.
(a) GPRS Communication Mode
(b)Telephone Line Communication Mode
(c) RS232 Communication Mode
(d) Ethernet Communication Mode
Functions
- The microprocessor adopts nanowatt technology, with wide working
pressure and low power consumption, the inner EEPROM can rewrite
for more than 100,000 times.
- Data hold and restoration function: the data in the water meter can
be stored for ten years when there is no power, when the power on,
with the data restoration function, the data can be read back by
devices.
- Replaceable battery design, replace by user self. Easy maintenance.
- The mechanical display is clear for reading, and the base meter can
be used for 10 years.
- Each meter has a unique ID No., and has complete production,
debugging, usage and maintenance record
Key features
- Adopt wireless communication technique to transmit data, thus no
need of communication cable layout, and reduce the installation
cost greatly.
- Electric floating ball valve technique: adopt electric ball valve
technique, work reliably and lower loss of pressure.
- Totally sealed design: all the circuits are sealed by high
performance casting glue, so there is no exposed electrode, and can
be used in moist environment.
- Anti-attack of strong electricity or magnetism: water meter will
give alarm when being attacked by strong electricity or magnetism.
- Micro-computer and microstorage technique: high integrated and high
reliability.
Product data sheet
Port size (DN) | 15 mm | 20 mm | 25mm |
Measure unit | 0.1 m³ |
Measure range ratio (Q3/Q1) | 80 |
Overload flow (Q4) | 3.125 m³/h | 5 m³/h | 7.875 m³/h |
Constant flow (Q3) | 2.5 m³/h | 4 m³/h | 6.3 m³/h |
Demarcation flow (Q2) | 0.05 m³/h | 0.08 m³/h | 0.126 m³/h |
Miniumal flow (Q1) | 0.0313 m³/h | 0.05 m³/h | 0.0788 m³/h |
Minmum reading | 0.0001 m³ |
Maximum reading | 99999 m³ |
Alarm | automatic valve close |
Working temperature | 0.1℃~30℃ (cold water meter) |
0.1℃~90℃ (hot water meter) |
Flow sensitivity level | Up zone: U10 Down zone: D5 |
Pressure level | △P63 |
Working pressure rating | 0.03 Mpa - 1.0 Mpa |
EMC | E1 |
Environment safety level | B |
Installation
- The installation of water meter meets the installation requirements
of ISO4064-2:2005
- The caliber of water meter shall correspond with caliber of pipes
and the used flow rate is less than or close to the permanent
flowrate. The installation place should avoid exposure, flooding,
freeze and pollution, and convenient for installing, removing and
reading data.
- The water meter shall be installed horizontally (display surface is
upward).
- The sands and stones and other sundries in the pipelines shall be
cleared.
- The arrow on the water meter should be the same as the water flow
in the pipeline.
- If the water meter is installed on the inlet of the boiler, it is
better to install inverted valve on the outlet of water to prevent
the return current of hot water and steam will damage the water
meter.
Pressure curve
Flow curve
Key features
- Contactless IC card (RF card) technique: adopt our company’s patent
technique of RF card, transmitting data by wireless way,
waterproof, moisture-proof and anti-attack
- Electric floating ball valve technique: adopt electric ball valve
technique, work reliably and lower loss of pressure
- Totally sealed design: all the circuits are sealed by high
performance casting glue, so there is no exposed electrode, and can
be used in moist environment
- Anti-attack of strong electricity or magnetism: water meter will
close valve automatically when being attacked by strong electricity
or magnetism
- Micro-computer and microstorage technique: high integrated and high
reliability
Product data sheet
Port size (DN) | 15 mm | 20 mm | 25mm |
Measure unit | 0.1 m³ |
Measure range ratio (Q3/Q1) | 80 |
Overload flow (Q4) | 3.125 m³/h | 5 m³/h | 7.875 m³/h |
Constant flow (Q3) | 2.5 m³/h | 4 m³/h | 6.3 m³/h |
Demarcation flow (Q2) | 0.05 m³/h | 0.08 m³/h | 0.126 m³/h |
Miniumal flow (Q1) | 0.0313 m³/h | 0.05 m³/h | 0.0788 m³/h |
Minmum reading | 0.0001 m³ |
Maximum reading | 99999 m³ |
Alarm | automatic valve close |
Working temperature | 0.1℃~30℃ (cold water meter) |
0.1℃~90℃ (hot water meter) |
Flow sensitivity level | Up zone: U10 Down zone: D5 |
Pressure level | △P63 |
Working pressure rating | 0.03 Mpa - 1.0 Mpa |
EMC | E1 |
Environment safety level | B |
Installation
- The installation of water meter meets the installation requirements
of ISO4064-2:2005
- The caliber of water meter shall correspond with caliber of pipes
and the used flow rate is less than or close to the permanent
flowrate. The installation place should avoid exposure, flooding,
freeze and pollution, and convenient for installing, removing and
reading data.
- The water meter shall be installed horizontally (display surface is
upward).
- The sands and stones and other sundries in the pipelines shall be
cleared.
- The arrow on the water meter should be the same as the water flow
in the pipeline.
- If the water meter is installed on the inlet of the boiler, it is
better to install inverted valve on the outlet of water to prevent
the return current of hot water and steam will damage the water
meter.
Competitive Advantage:
- Compliance to international standards: ISO4064 / GBT778 /
Q/320700JR05-2003
- Strict process control
- Advanced calibration equipment
- Engineer team
Production line
Company Profile
Shanghai I Fluid Technology Co., Ltd, a technique based company. We
focus on the deployment , installation and management system of
smart metering and smart grid in all utility sectors, include but
not limited to water, heat, gas and electricity.
To adapt to the global environment protection trends, and China
government policy, China put the green energy application and EIA
at their first place. We do our best contribution to the government
energy saving policy.
We put emphasis on central air conditioning system, energy
distribution system in separated areas, green energy application in
commercial buildings, municipal water / gas / heat supply, sewage
discharge monitoring, and many other industrial applications.
Adhere to the principle of “ low carbon energy, build future”, we
aim to give solution to take the best avail of natural resources,
improve energy efficiency, reduce energy consumption. Through more
renewable energy, reasonable energy store technique, and minimize
energy demands, we help our clients to build an intelligent low
carbon energy network. Build the optimized electricity, heat, water
and gas supply and demands system, finally to realize the LOW to
ZERO energy system.
Over tens of years developing, we design and manufacture a complete
set of energy relating products: central air condition with
variable ventilation and ventilate at low temperature, flexible
central air conditioning, cooling store capacitor, AMR/AMI,
metering and level products.