Home /Industrial Chiller /

French Tecumseh Auto Computer Constant Temperature Humidity Chamber Water-Cooling

French Tecumseh Auto Computer Constant Temperature Humidity Chamber Water-Cooling

Brand Name:HD
Certification:ISO,CE
Model Number:HD-E702
Minimum Order Quantity:1 set
Delivery Time:15 Days After Order
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Room 105, Building F4, District F, Tianan Digital City, Nancheng District, Dongguan City, Guangdong Province,China
Supplier`s last login times: within 37 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

French Tecumseh Auto Computer Constant Temperature Humidity Chamber Water-Cooling


Temperature and humidity chamber.pdf


1. Performance

French Tecumseh Auto Computer Constant Temperature Humidity Chamber Water-Cooling can simulate both temperature and humidity. Controlled humidity from 10% RH to 95% RH can be maintained within the dry-bulb temperature range of +10°C to +85°C, limited by a 6°C dew point. For lower dew point conditions (low RH or relative humidity at low dry-bulb temperatures), you will need dry air purge or GN2 (gaseous nitrogen) purge. See the humidity range chart on the specification page of each temperature-humidity chamber for humidity range limits.


System & Performance Options

  • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed)
  • Water-cooling system.
  • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
  • Additional shelves, 50 Kg loading
  • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

2. Specifications of French Tecumseh Auto Computer Constant Temperature Humidity Chamber Water-Cooling


Range – 70 to 150°C


Temp/HumidityHD-E702-100-7HD-E702-150-7HD-E702-225-7
HD-E702-408-7HD-E702-800-7HD-E702-1000-7
Temp-onlyHD-E702-100T-7HD-E702-150T-7HD-E702-225T-7
HD-E702-408T-7HD-E702-800T-7HD-E702-1000T-7
Temperature Range:-70°C ~150°C
Cooling Capacity~ 2.5 kW at -50°C~ 3 kW at -50°C~ 5 kW at -50°C
~ 6.5 kW at-50°C~ 8.5 kW at -50°C~ 9 kW at - -50°C
Heating System~ 5 kW~ 5 kW~ 5.5 kW
~6.5 kW~ 8.5 kW~ 9 kW
Temperature Fluctuation:±0.5°C
Temperature Gradient:±0.5°C~±0.2°C
Heating Rate†:≥3℃ / min average ( Advance model 5 – 15 ℃ / min)
Cooling Rate†:≥1℃ / min average (Advance model 5 - 15℃ / min)
Humidity Range:10%~95%RH (Ref to Normal Humidity Range Diagramed)
Humidity Fluctuation:±1.5%RH~±2.0%RH
Humidity Gradient:±3%RH
Dimensions
Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225

850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:
1400x850x10501500x950x10501650x950x1150
1750x1050x13501900x1450x13501900x1450x1550
Site Requirements
Electrical Supply:208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)
Humidity WaterDistilled water
Condensate Drain:1/2" hose connection (gravity drain)

Range – 40 to 150°C


Temp/HumidityHD-E702-100-4HD-E702-150-4HD-E702-225-4
HD-E702-408-4HD-E702-800-4HD-E702-1000-4
Temp-onlyHD-E702-100T-4HD-E702-150T-4HD-E702-225T-4
HD-E702-408T-4HD-E702-800T-4HD-E702-1000T-4
Temperature Range:-40°C ~150°C
Cooling Capacity~ 2 kW at -20°C~ 2.5 kW at -20°C~ 4.5 kW at -20°C
~ 5.5 kW at-20°C~ 8 kW at -20°C~ 8.5 kW at - -20°C
Heating System~ 5 kW~ 5 kW~ 5.5 kW
~6.5 kW~ 8.5 kW~ 9 kW
Temperature Fluctuation:±0.5°C
Temperature Gradient:±0.5°C~±0.2°C
Heating Rate†:≥3℃ / min average ( Advance model 5 – 15 ℃ / min)
Cooling Rate†:≥1℃ / min average (Advance model 5 - 15℃ / min)
Humidity Range:10%~95%RH (Ref to Normal Humidity Range Diagramed)
Humidity Fluctuation:±1.5%RH~±2.0%RH
Humidity Gradient:±3%RH
Dimensions
Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225

850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:
1400x850x10501500x950x10501650x950x1150
1750x1050x13501900x1450x13501900x1450x1550
Site Requirements
Electrical Supply:208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)
Humidity WaterDistilled Water
Condensate Drain:1/2" hose connection (gravity drain)

3. Features:

Stainless steel exterior
Full thermal break around doorframe
One 50mm (2") diameter cable port on left, with flexible silicone plug
Three levels of overheat protection
115V main power for BTL-433 model
High performance and quiet operation (65 dBa)
Easy lift-off service panels, electrical access on left



WATLOW F4T PROGRAMMER/CONTROLLER


Popular PID controller with touch-screen operation
Stores 40 different profiles
Step types include: ramp, soak, jump/repeat, auto-start, and end
Ethernet interface for remote monitoring and operation


Standard Features:

  • Stainless# 304 steel for interior
  • Paint steel for exterior
  • Foam-insulated door for rigidity and long life
  • Plastic water tank easy for maintenance
  • Observation Window with frost free function
  • High performance refrigeration system
  • Easy user interface for TEMI-880 PLC controller
  • One 100mm cable port/ Customer specified
  • One shelve, 10 Kg loading & 4 casters included
  • Van Type Sirocco,L134,Fan
  • PID controlled-Stainless Steel Humidifier
  • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
  • USB port for data output
  • Anti-explosive interior lamps
  • Data logging chart recorders, paperless recorders stored data in the PLC.

Performance indicators


Temperature Range RT + 10 ℃ ~ 100 ℃ Humidity 80 ~ 98% R · H fluctuation / uniformity ≤ ± 0.5 ℃ / ± 2 ℃ temperature deviation +2%, - 3% R · H Heating time of about 20min at room temperature ~ 100 ℃ temperature control ± 1 ℃ ± 2%



Control System
Imported microcomputer temperature controller wet integrated controller (display directly percent humidity).
Accuracy range setting accuracy: temperature ± 0.1 ℃, humidity ± 0.1% R · H, indicating accuracy: temperature ± 0.1 ℃, temperature ± 0.1% R · H temperature and humidity sensors platinum platinum resistance · PT100Ω.
Heating system is completely independent system, electric heating nichrome heater.
Isolated external humidification systems, stainless steel boiler type shallow surface evaporative humidifier.
Circulatory system temperature low noise air conditioning motors, leafy centrifugal wind wheel.


Heating system
Far-infrared heating using nickel-chromium alloy heating wire heating speed;
High temperature, low temperature completely independent systems;
Temperature control P · I · D + S · S · R system with channel coordination control;
Temperature control the output power by the microcomputer calculus, to achieve high accuracy and high efficiency power efficiency.



China French Tecumseh Auto Computer Constant Temperature Humidity Chamber Water-Cooling supplier

French Tecumseh Auto Computer Constant Temperature Humidity Chamber Water-Cooling

Inquiry Cart 0