Home /Measuring & Analysing Instrument Processing Services /

Humidity testing Low and empty water level alarm Temperature Humidity Chamber

Humidity testing Low and empty water level alarm Temperature Humidity Chamber

Brand Name:Haida
Certification:CE,,ISO
Model Number:HD-E702
Minimum Order Quantity:1
Delivery Time:15 Days After Order
Payment Terms:L/C, T/T, D/A, D/P, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: Room 105, Building F4, District F, Tianan Digital City, Nancheng District, Dongguan City, Guangdong Province,China
Supplier`s last login times: within 37 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Humidity Testing Low And Empty Water Level Alarm Temperature Humidity Chamber


Temperature and humidity chamber.pdf

Download:Temperature and humidity chamber.pdf


Function and Application:
Humidity testing Low and empty water level alarm Temperature Humidity Chamber is mainly for testing and determining the parameters and performance of electrical, electronic products, chemicals and materials upon the change of the environment in high-temperature, low-temperature or constant test.It can simulate different environmental conditions (temperature and humidity) on a product or material, It's appropriate for testing material performance, such as resist heat, resist dry and resist cold. It is widely applicable to aircraft industry, automobileindustry,semiconductors,chemicals,pharmacy,foodstuffs,home appliance industry and scientific research field.
Structure and Characteristics:

1.temperature humidity chamber is composed of the chamber, refrigeration systems, heating systems, air circulation system and control system.
2.The working chamber is made of high quality SUS#304 stainless steel material,the outer shell adopts A3 steel plate,surface electrostatic spraying.
3.Insulation system uses superfine fiberglass wool or polyurethane foam so as to ensure the temperature of inside chamber.
4.Temperature and humidity control adopts Korean import TEMI880 programmable touch screen temperatureand humidity controller, with automatic calculation of PID function.
5.Adopts steam humidifying method, automatic water circulation loop,with functions of automatic filling water.
6.Refrigeration system adopts original France "Tecumseh" refrigeration unit and full sets of refrigeration parts.
7.Input mode PT100 sensor.
8.The system of heating up, heating down, dehumidifying, and humidifying can be operated independently so as to reduce the cost of testing, extend the operating life of the machine and decrease the failure rate.

Standard Features:

  • Stainless# 304 steel for interior
  • Paint steel for exterior
  • Foam-insulated door for rigidity and long life
  • Plastic water tank easy for maintenance
  • Observation Window with frost free function
  • High performance refrigeration system
  • Easy user interface for TEMI-880 PLC controller
  • One 100mm cable port/ Customer specified
  • One shelve, 10 Kg loading & 4 casters included
  • Van Type Sirocco,L134,Fan
  • PID controlled-Stainless Steel Humidifier
  • DuPont R-404A [No Fluorine] Refrigerant / 23 for below -40 °C
  • USB port for data output
  • Anti-explosive interior lamps
  • Data logging chart recorders, paperless recorders stored data in the PLC.

2. Specifications :


Range – 40 to 150°C


Temp/Humidity

HD-E702-100-4

HD-E702-150-4

HD-E702-225-4


HD-E702-408-4

HD-E702-800-4

HD-E702-1000-4

Temp-only

HD-E702-100T-4

HD-E702-150T-4

HD-E702-225T-4


HD-E702-408T-4

HD-E702-800T-4

HD-E702-1000T-4

Temperature Range:

-40°C ~150°C

Cooling Capacity

~ 2 kW at -20°C

~ 2.5 kW at -20°C

~ 4.5 kW at -20°C

~ 5.5 kW at-20°C

~ 8 kW at -20°C

~ 8.5 kW at - -20°C

Heating System

~ 5 kW

~ 5 kW

~ 5.5 kW

~6.5 kW

~ 8.5 kW

~ 9 kW

Temperature Fluctuation:

±0.5°C

Temperature Gradient:

±0.5°C~±0.2°C

Heating Rate†:

≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

Cooling Rate†:

≥1℃ / min average (Advance model 5 - 15℃ / min)

Humidity Range:

10%~95%RH (Ref to Normal Humidity Range Diagramed)

Humidity Fluctuation:

±1.5%RH~±2.0%RH

Humidity Gradient:

±3%RH

Dimensions

Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225


850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:

1400x850x1050

1500x950x1050

1650x950x1150


1750x1050x1350

1900x1450x1350

1900x1450x1550

Site Requirements

Electrical Supply:

208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

Humidity Water

Distilled Water

Condensate Drain:

1/2" hose connection (gravity drain)


Range – 70 to 150°C

Temp/Humidity

HD-E702-100-7

HD-E702-150-7

HD-E702-225-7


HD-E702-408-7

HD-E702-800-7

HD-E702-1000-7

Temp-only

HD-E702-100T-7

HD-E702-150T-7

HD-E702-225T-7


HD-E702-408T-7

HD-E702-800T-7

HD-E702-1000T-7

Temperature Range:

-70°C ~150°C

Cooling Capacity

~ 2.5 kW at -50°C

~ 3 kW at -50°C

~ 5 kW at -50°C

~ 6.5 kW at-50°C

~ 8.5 kW at -50°C

~ 9 kW at - -50°C

Heating System

~ 5 kW

~ 5 kW

~ 5.5 kW

~6.5 kW

~ 8.5 kW

~ 9 kW

Temperature Fluctuation:

±0.5°C

Temperature Gradient:

±0.5°C~±0.2°C

Heating Rate†:

≥3℃ / min average ( Advance model 5 – 15 ℃ / min)

Cooling Rate†:

≥1℃ / min average (Advance model 5 - 15℃ / min)

Humidity Range:

10%~95%RH (Ref to Normal Humidity Range Diagramed)

Humidity Fluctuation:

±1.5%RH~±2.0%RH

Humidity Gradient:

±3%RH

Dimensions

Workspace dimensions
(WxDxH)mm:

500x400x500

HD-E702-100

600x500x500

HD-E702-150

750x500x600

HD-E702-225


850x650x800

HD-E702-800

1000x1000x800

HD-E702-800

1000x1000x1000

HD-E702-1000

Exterior dimensions
(WxDxH)mm:

1400x850x1050

1500x950x1050

1650x950x1150


1750x1050x1350

1900x1450x1350

1900x1450x1550

Site Requirements

Electrical Supply:

208V 3Ø 60Hz or 230V 3Ø 60Hz (customer specific)

Humidity Water

Distilled water

Condensate Drain:

1/2" hose connection (gravity drain)


3. Performance of Stability High Low Temperature and Humidity Test chamebr:


Get a performance evaluation to help provide the suitable chambers to you.


For better assurance of performance for your temperature and humidity cycling application, Haida can provide a guaranteed performance calculation based on your submitted requirements.


Please use these questions as below as a guide to define your test plan. You can then give this information to our lab consultant or email to us, for review by our lab consultant. A recommended model with appropriate refrigeration size will provide to you.


Features:
1.Non-corrosive
2.Highly Efficient
3.Long service life
4.Perfect Design
5.Sturdy construction
6.Air circulation for uniform airflow within the inner chamber
7.Temperature and humidity be controlled independently.
8.Adopts environmentally Refrigerant
Optional Accessories:
1.Japan import "OYO" Touch Screen Programmable temperature controller/Japan import UMC series Touch ScreenProgrammable temperature controller
2.Germany "Copeland" semi-closed refrigeration compressors
3.RS485 port and communication
4.Temperature test hole
5.Extra shelves

System & Performance Options

  • Low and Ultra-Low Humidity Extends the humidity control range. (Normal Humidity Range Diagramed)
  • Water-cooling system.
  • Dry Air Purge keeps moisture in the chamber extremely low by purging with -40 °C. Compressed air supply required
  • Additional shelves, 50 Kg loading
  • Cable ports with flexible silicone plug, 50 , 100, 150mm or customer specific diameters

(Normal Humidity Range Diagramed)


4. view:




(Advanced refrigeration design is especially compact for HD-Series Chambers)

China Humidity testing Low and empty water level alarm Temperature Humidity Chamber supplier

Humidity testing Low and empty water level alarm Temperature Humidity Chamber

Inquiry Cart 0