Add to Cart
Model: 9V lithium manganese battery 1200mAh
Specification
Nominal voltage: 9.0V
Nominal capacity: 1200mAh
Operating temperature range: -20 DEG C, ----60 DEG C
Storage temperature range: -40 DEG C, ----60 C
Maximum continuous discharge current: 150mA
Maximum pulse discharge current: 300mA
Battery terminals: nickel (-), stainless steel or nickel (+) lugs
Battery Cell Performance Criteria
Standard testing environment
Unless specifically stated otherwise, tests must be done within one month of delivery.
The following is test conditions:
Test conditions:
Ambient Temperature: 25ºC ± 1ºC Ambient Humidity: 45~75%RH
The requirement of measure instrument
(1) The measurement instrument has been certified by a qualified source.
(2) The accuracy of the measuring instrument is less than 0.01mm.
(3) The accuracy of multimeter is at least 0.5%.
(4) The current accuracy of the battery test system is at least ±0.1%, isobarically accuracy is
±0.5%, and timer accuracy is not less than ±0.1%.
(5) The accuracy of the thermometer is at least ±0.5ºC.
Visual inspection
Not allowing any visual defects which will affect the electronic characteristics, such as leakage and damage.
Recommended Notice:
Using cells on specified facilities only.
Using cells in normal ambition temperature. Temperature: -10~35℃,Relative Humidity:
45~75%.
Using the cells, away from heat source. Don’t let children play with cells.
Avoid the positive pole shortcutting with the negative one. Avoid the cells affected with damp.
Useless cells should be deal with in a safety way. Don’t drop them into the water or fire.
High and low temperature test
No. | Item | Testing Conditions and Method | Standard |
1 | High Temperature | A battery is placed in an oven for 2 hours at 55ºC±2ºC, then discharged at a 1mA current to the termination voltage. | Discharge 90 percent of the original capacity. |
2 | Low Temperature | A battery is placed in a thermal chamber for 2 hours at -10ºC±2ºC; then discharged at 1mA to the termination voltage. | Discharge more than 45 percent of the original capacity. |
Drawing:
Picture: