Home /Electronic Signs /

4 Core XLPE Insulated Aerial Bundled Cable For Overhead Distribution Lines

4 Core XLPE Insulated Aerial Bundled Cable For Overhead Distribution Lines

Brand Name:SHANCABLE
Certification:CE ROHS KEMA
Model Number:ABC
Minimum Order Quantity:1000m
Delivery Time:15 Days
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Shanghai Hunan China
Address: No.7577 Hunan Road, Pudong New District. Shanghai China
Supplier`s last login times: within 35 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

4Core With XLPE Insulated Aerial Bunch Cable For Overhead Distribution Lines


Specifications

To supply power from the utilitys lines to the consumers weatherhead.For service at 600 volts or less(phase to phase).

Aerial Bundled Cable is a new type aeral bundled cable used for transmitting electric power overhead.


Standards


1. B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
2. B-231 Aluminum Conductors, Concentric-Lay-Stranded.
3. B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
4. B-399 Concentric-Lay_Stranded 6201-T81 Aluminum Alloy Conductors.
5. B498 Zinc-Coated Steel Core Wire for Aluminum Conductors, Steel Reinforced (ACSR).
6. Duplex Service Drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474


Applications


To supply power from the utilitys lines to the consumers weatherhead.For service at 600 volts or less(phase to phase) at a conductor temperature of 75oC maximum for polyethylene insulation or 90 oC maximum for crosslinked insulation.


Construcrtion


1.stranded aluminium conductor

2.PE or XLPE insulation

3.ACSR, AAAC,Galvanised steel wire Messenger wire
3 power cores consisting of standard aluminium conductors, insulated with XLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor


Technical Data:
Maksimum operating temperature 90 degree
Maximum short-circuit temperature 250 degree.Service drop( ABC cables) are especially used at areas where the cost of underground networks is expensive and also for electrification of rural areas like village.


Classification


1. Duplex Service Drop


Primary used for 120 volt overhead service application such as street lighting, outdoor lighting, and temporay service for construction. To be used at voltages of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.


2.Triplex Service Drop


Used to supply power, usually from a pole-mounted transformer to the user's service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.


3. Quadruplex Service Drop


Used to supply 3 phase power, usually from a pole-mounted transformer to the user's service head where the connections to the service entrance cable is made. To be used at voltage of 600 volts phase to phase or less and at conductor temperature not to exceed 75degee for polyethylene insulated conductor or 90 degree for crosslinked polyethylene (XLPE)insulated conductors.


Schedule of technical particulars


Phase conductor
Nominal cross-sectional areamm²2535507095120150185
Number of cores33333333
Minimum number of wires6661215153030
Nominal insulation thicknessmm1.21.21.41.41.61.61.82.0
Diameter of insulated coremm8.59.511.213.015.116.618.420.6
Max. DC resistance at 20℃ohm/km1.200.8680.6410.4430.3200.2530.2060.164
Current rating at still wind, ambientA84104129167209246283332
temperature=30℃
Conductor temperature=75℃
Messenger conductor
Nominal cross-sectional areamm²25253550707095120
Minimum number of wires666612121515
Nominal insulation thicknessmm1.21.21.21.41.41.41.61.6
Diameter of insulated coremm8.58.59.511.213.113.115.116.6
Max. DC resistance at 20℃ohm/km1.3121.3120.9430.6930.4690.4690.3490.273
Calculated breaking loadkN6.46.48.912.118.018.024.230.8
Street lighting conductor
Nominal cross-sectional areamm²25253550707095120
Minimum number of wires666612121515
Nominal insulation thicknessmm1.21.21.21.41.41.41.61.6
Diameter of insulated coremm8.58.59.511.213.113.115.116.6
Max. DC resistance at 20℃ohm/km1.3121.3120.9430.6930.4690.4690.3490.273
Completed cable
Approx. overall diametermm23.225.630.034.940.644.149.254.9
Approx. weight of cablekg/km4705607409801330158019402410
Packing lengthm/drum1000100010001000500500500500

China 4 Core XLPE Insulated Aerial Bundled Cable For Overhead Distribution Lines supplier

4 Core XLPE Insulated Aerial Bundled Cable For Overhead Distribution Lines

Inquiry Cart 0