Home /Gas Generation Equipment /

Liquid Oxygen Plant 2000nm³/h Large Skid Mounted Air Separation Plant Equipment

Liquid Oxygen Plant 2000nm³/h Large Skid Mounted Air Separation Plant Equipment

Certification:ISO9001;2008 CE cetificate
Model Number:KDO 2000Y
Minimum Order Quantity:1set
Delivery Time:60working days after received your payment
Payment Terms:T/T or L/C
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Supplier`s last login times: within 15 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

99.6% Air Separation Plant KDO 2000Y Industrial Oxygen Plant With Low Energy Consumption


  • Annex 1. Plant design basis (need buyer’s confirmation)

    Design point of Atmosphere

    Ø Atmosphere pressure

    101.3kPa(A)

    Ø Atmosphere tempt.

    30℃

    Ø Relative humidity

    75%

    Ø O2 contained in air

    20.95% O2

    Atmosphere tempt.

    Ø Annual average tempt.

    18.4℃

    Ø Max. Tempt.

    40℃

    Ø Min. Tempt.

    -1.8℃

    Ø Summer average tempt.

    30℃

    Ø Winter average tempt.

    7.5℃

    Earthquake degree:

    <6 degree

    Altitude:

    50m

    Impurity in air

    Ø CO2

    ≤450 ppm

    Ø SO2

    ≤0.44 mg/m3

    Ø H2S

    ≤2.3 mg/ m3

    Ø CH4

    ≤5.2mg/ m3

    Ø C2H2

    ≤0.03 ppm

    Ø CnHm(excluding C2H2)

    ≤5 ppm

    Ø Mechanical impurity

    ≤10mg/m3

    Recycle water

    Ø Inlet tempt.

    30℃

    Ø Inlet pressure

    0.4 MPa(G)

    Ø Max pressure drop

    0.2 MPa(G)

    Ø Max tempt. rising

    10℃

    Ø Turbidity of cooling water

    12 mg/L

    Ø PH value

    7.2

    Ø Rigidity

    2.5

    Ø Fouling factor

    0.0004 m2 hºC/ K.W

    Power condition

    Ø High voltage power

    10,000V±5% 3 phases 3 ways

    Ø Low voltage power

    380V/220V±5% AC 3 phases 4 ways

    Ø Frequency

    50±0.5HZ

    Instrument gas ( used for starting)

    Ø Pressure

    0.5 MPa(G)

    Ø Tempt.

    ≤30 ℃

    Ø Dew point

    <-40℃

    Ø Flow

    300m3/h

    Ø Requirement

    NO OIL

    Annex 2. Main parameter

    Production Capacity And Purity(Out Of Cold Box):

    Medium

    capacity (Nm3/h)

    purity

    pressure(MpaG)

    Liquid Oxygen

    2000±5%

    ≥99.6% O2

    0.14

    Note:The capacity means liquid production to convert to gas.

    Capacity and purity are calculated as 0 m altitude from the outlet of cold box.

    Nm3/h is under condition of 0℃,760mmHg. If not figured, the pressure is absolute pressure ( same as below).


    Running period between 2 defrosting times )

    >2years

    Defrosting time

    ~36hours

    Starting time
    from start the turbine to get the production ( excluding commissioning for argon)

    ~24hours


    1. Power consumption

    NO.

    Equipment

    Motor power(rated power)kW

    Shaft power kW

    Voltage stage

    Remarks

    1.

    Raw air compressor

    993

    921

    10KV


    2.

    Boosting compressor

    1500

    1340

    10KV

    Hangyang or same level manufacturer

    3.

    Air precooling unit

    70

    50

    380/220V


    4.

    M.S. purifier

    Electric heater

    160

    Average using 50

    380/220V

    One for running and one for standby,Intermittent running

    5.

    Expander oil pump

    3

    2

    380/220V

    One for running and one for standby

    6.

    Liquid storage system

    Liquid O2 delivery pump

    15

    10

    380/220V

    Intermittent running

    7.

    Instrument control system


    Average using 10

    380/220V


    Plant average power consumption(calculate as shaft power,exclude liquid storage system and utilities):~2373kW


  • Annex 3 Description of the process: Description of the process:
    • Design principle of this plant is based on the different boiling point of each gas in the air. Air is compressed, precooled and got removal of H2O and CO2, then to be cooled in the main heat exchanger until it is liquefied. After rectification, production oxygen and nitrogen can be collected.

Annex 4. Scope of supply

  1. Raw material filter

1set

Technical parameter(note:determined by final design)

Manufacturer

Sead

Type

Self cleaning

Process capacity

~20600m3/h

Filter efficiency

≥99.8 %

Filter resistance

≤0.65KPa

Installation type

VERTICAL

Filter material

foliage fiber

Scope of supply (note:determined as manufacturer’s final list)

Q.T.

Ø FILTER HOST BODAY

1

Ø Counter blowing and control system

1

Ø Filter bucket

1

Ø Spare parts

1

Image (for reference, determined by final design)



  1. Turbine air compressor

1 Set

Technical parameter(note:determined by final design)

Manufacturer

Samsung Or IHI

Compressing media

Air

Cooling water inlet temp.

≤30 ℃

Cooling water supply pressure

0.4 Mpa

Design gas discharge flow

10300Nm3/h

Discharge pressure

0.6MPa(A)

Compressing stages

Three stage

Main motor fixed power

~993KW

Shaft power

~921KW

Cooling water consumption

~112m3/h

Discharge tempt

~40 ℃

oil content

100% non oil

adjustment

70 %~100 %

Ø After primary rectification in lower column, liquid air and pure liquid nitrogen can be collected in lower column. Waste liquid nitrogen, liquid air and pure liquid nitrogen flows to upper column via liquid air and liquid nitrogen cooler. It is rectified in upper column again, after that, liquid oxygen of 99.6% purity can be collected at the bottom of upper column, and is delivered out of the cold box as production.

Waste nitrogen from top of upper column flows out of the cold box to purifier as regenerative air, rest goes to cooling tower.

Ø This plant is of MS purification of air with boosting turbine expander process.

Raw air goes to air filter for removal of dust and mechanical impurity and enters air turbine compressor where air is compressed to~0.6MpaA,Then it goes into air precooling system, where air is cooled to 10℃,After that, it flows to 2 molecular sieve adsorbing tank, which are running in turn, to be got removal of H2O, CO2 and C2H2. After purified, air mixes with expanding reheated air. Then it is compressed by middle pressure compressor to be divided into2 streams. One part goes to main heat exchanger to be cooled to~250K, and sucked from the middle part of main heat exchanger to enter expansion turbine. Expanded air returns to main heat exchanger to be reheated, after that, it flows to air boosting compressor. The other part of air is boosted by high temperature expander, after cooling, it flows to the low temperature boosting expander. Then it goes to cold box to be cooled to ~243K. Part of it would still be cooled, and flows to bottom of lower column via heat exchanger. And other air is sucked to low tempt. expander. After expanded, it is divided into 2 parts. One part goes to the bottom of lower column for rectification, the rest returns to main heat exchanger, then it flows to air booster after being reheated.


99.6% Air Separation Plant KDO 2000Y Industrial Oxygen Plant With Low Energy Consumption


Liquid O2 output2000nm3/h
Liquid O2 purity>99.6%
Liquid O2 pressure0.14mpa
Running period>2years
Defrosting time0-36hours
Starting time0-24hours
High voltage10000V
Low voltage380V/220V
Frequency50Hz


China Liquid Oxygen Plant 2000nm³/h Large Skid Mounted Air Separation Plant Equipment supplier

Liquid Oxygen Plant 2000nm³/h Large Skid Mounted Air Separation Plant Equipment