Home /HVAC Systems & Parts /

1.5V Alkaline Batteries LCD Display Smart Home Digital Room Thermostat For Heating / OFF / Cooling

1.5V Alkaline Batteries LCD Display Smart Home Digital Room Thermostat For Heating / OFF / Cooling

Brand Name:OEM/OEM
Certification:CE/UL
Model Number:ST2601
Minimum Order Quantity:1PC
Delivery Time:7-30 days
Payment Terms:L/C, D/A, D/P, T/T, Western Union, MoneyGram/Paypal
Contact Now

Add to Cart

Verified Supplier
Address: Unit C,9/F Winning House,No.72-74 Wing Lok Street, Sheung Wan,Hongkong
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

LCD Display Smart Home Digital Room Thermostat For Heating / OFF / Cooling


ISO certifications .pdf


Features:


Digital thermostat
Wall mounted
Heat/OFF/Cool switch
Room Temperature Calibration adjustment
Power supply: 230 VAC,6(2)A,50/60 Hz for hardwire (common wire)
2*AAA 1.5V Alkaline batteries power


Model No.:ST2601


1Product Name:Color Touch Heating Thermostat
2Programmability: No
3Display temperature range:0°C~40°C (in 0.1°C increments)
4Setpoint Range:5°C~35°C (in 0.5°C increments)
5Temperature measurement accuracy:±1°C (at 20°C)
6Backlight:Orange/White/Blue...
7Power Method:2 x AAA 1.5V Lithium batteries
8Dimensions:130 x 86 x 35 mm (without holder)
9Running Mode:HEAT/OFF/COOL MODE
10Load Rating: 6(2)A, 230V
11Standby current: <70uA, Lighting current ≤7.2mA

Relay Wiring


1(NC),2(COM),3(NO)


Heating: connect the two connection wires of the device to be controlled to terminals No. 3 (NO) and No. 2 (COM), i.e. to the normally open terminals of the relay

Cooling: the two connection wires of the cooling equipment should be connected to terminals No. 2 (COM) and No. 1 (NC), i.e. to the normally closed terminals of the relay.


• To prevent electric shock, replace the inner cover removed for the connection of wires after the assembling process has been completed.


The device must be installed and connected by a qualified professional. Always follow the manufacturer's instructions when connecting the thermostat to any heating or cooling appliance.


The voltage appearing at terminal No. 1, No. 2 or No. 3 depends only on the system being controlled, therefore the dimensions of the wire are determined by the type of the device to be controlled. The length of the wire is of no significance.


Running Mode


Hold the dial button for 5 seconds to access the system running mode switch, then turn the dial to choose different mode between:


-- HEAT (Heating): adjust the temperature by turn the dial

-- COOL (Cooling): adjust the temperature by turn the dial

-- OFF (Frost Protection): it will start heating when the room temperature is under 7°C


Then press the dial again to confirm the running mode or wait for 10 seconds to confirm the setting automatically.


Calibrate the temperature


Temperature calibration and SWING settings): Hold the dial for 5 seconds to access to the mode switch setting and select HEAT or COOL mode, then press the dial to access the interface of temperature calibration “CAL” (in -3.0~+3.0, in 0.5°C increments); turn the dial to set the desired value, then press the dial again to set the Swing value between 0.2~2°C.


Restoring thermostat to factory default


Remove the batteries then put it back, hold the dial until display the full screen then release, the defaul running mode is HEAT, it means the thermostat has been restored to factory default settings.



China 1.5V Alkaline Batteries LCD Display Smart Home Digital Room Thermostat For Heating / OFF / Cooling supplier

1.5V Alkaline Batteries LCD Display Smart Home Digital Room Thermostat For Heating / OFF / Cooling

Inquiry Cart 0