Home /Other Beauty & Personal Care Products /

Multifunction RF Beauty Machine Liposuction Slimming Machines With Touch Screen 60Hz RV9

Multifunction RF Beauty Machine Liposuction Slimming Machines With Touch Screen 60Hz RV9

Brand Name:kimlida
Certification:CE
Model Number:KS-08
Minimum Order Quantity:1unit
Delivery Time:7 days after full payment
Payment Terms:T/T, western union, paypal, credit card
Contact Now

Add to Cart

Active Member
Location: Guangzhou Guangdong China
Address: Room 416,Building B,qifu hotel No.888,qifu road,xinshi street,bai yun district,Guangzhou,china
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Multifunction RF Beauty Machine Liposuction Slimming Machines With Touch Screen 60Hz RV9


Lipo slimming

Cavitation weight loss 40K

Tripolar RF face lifting 5Mhz

Multi RF body body shape slimming


portable beauty equipment vacuum liposuction slimming RV9

Specification


Cavitation Body Applicator


Ultrasonic Cavitation

- Powerful cavitation effect from dual generators

- Effective treatment by 4 types of pulse mode

- Guaranteed treatment results

- Operatingsignal light fuction

Vacuum & Roller Body Applicator


Vacuum & Roller


- Auto-roll applitor pull the target area skin to enhance vacuum suction effect.

- Specialized for leg, and body

- Powerful vacuum performance and dynamic pulse techniques

- Power lifting and liposlim care


RF Body Applicator


Multi-Polar RF, and LED

- Specialized dynamic vibration function

- Easy to use technical motions

- Red LED technology

- Updated Multi-Polar RF technology

- Stable multi-polar RF system (5MHz)

RF Facial Applicator


Tri-Polar RF, and LED

- Dramatic result for facial lifting

- Dramatic & strong vibration function

- Effective facial lymphatic drainage


The core effect

1) Reduction of cellulite and local fat

2) Stimulation blood circulation and lymph drainage

3) Drainage of toxins and edema

4) Skin toning, lifting, firming and scalp massage

5) Improce to Liposuction, Meso-therapy and Hydro-lipolysis


Technical specification:

Voltage

110V/220V

Ultrasound frequency

40KHz

Radio frequency

5MHz

Vacuum range

650 mmHg

Panel

8 inches, digital touch screen

Laser spectrum

650nm(diode laser)

Dimensions

53*53*41cm

GW

18KG


40K Cavitation Working principle

40K Strong sound waves explosion head effectively promote the organization fat metabolism, repel orange peel fat, firming skin, enhancing skin elasticity, etc. And the effect is long lasting. The 40 K sound waves can make a implosion of liquid as the expansion and compression of the wave make the inside of the liquid formed in many small space and what inside this kind of space are gas and steam. During the compression cycle, the 40K sound waves have positive pressure effect on the liquid molecules, while during the expansion cycle the 40K sound waves have positive pressure effect on the liquid molecules. There are cohesion inside of liquid or and biological organization. Inside of the low density fat cells, the cohesiveness of the molecular is weaker.

The low negative pressure which is produce by 40 K sound waves will produce organization gap which is called "cavitation phenomenon" in physics. The implosion of inside and outside of the cells will enhanced the molecular motion and achieve a high energy level, and eventually led to the bursting of the fat cells.


40K cavitation operation procedure

Click “BODY UITRA-CAVITATION” enter the operation interface.


1. System default working time is 30 minutes, time range is 0:00~60:00 minutes, press one time to change one minute.

2. The system default Intensity is 0. The intensity range is 0~10 (standard parameters), press one time to change one unit of standard parameters.

3. The system default output of band is the third one (Continuous band), you can choose the band by click the band mode.


4. Click “START”, it starts working and “STOP” for stop working

Press “BACK”, you can get back to the operation interface.

5. Beautician hold the cavitation work head to move slowly on skin, in circle or beeline repeatedly.

6. Do not use on back, avoid using on bones.

7. Do not use on uterus part when women do abdomen care. Abdomen treatment during menstruate should be avoided.

8. The machine will pause automatically if the setting time is over. Please click any place of the screen according to the hint.

9. Clean the leftovers with hot towel, use warm towel to clean the cavitation explode work head.


Caution for using 40K

1. Applied enough gel on skin need treated.

2. Do not stay unmoved on any part of your body ,do not stay on bones.

3. The total treatment time for daily should be within 30 minutes.

4. Do not allow to be placed under the state of no-load to avoid the damage caused by high heat.

5.40K work head can be used on fresh part of the body, Do not use for facial. If the skin is sensitive or becomes unhealthy, the strength of the power should be adjusted down.


Multipolar circulation RF principle


【Skin rejuvenation principle】The circulation medical radio frequency system in 1 seconds will change the electric polarity in electric field millions times of the biological tissue of the therapeutic part , particles of the organization will do Brownian motion(molecular no rules movement) as the same frequency which will make the organization produce columnar distribution of heat, damage collagen hydrogen bonding structure and change the collagen molecules of the three spiral structure, and lead to the immediate collagen sex contraction and as a result of the treatment effect of firming skin;


According to ajusting the energy output, the circulation system makes skin tissues have mild, moderate and severe heat aggression three stages which is similar as the three stages in wound healing (inflammation stage, growth stage, remodeling stage), improve leather remodeling shape, so as to reconstruct the skin and dispel light, medium, heavy wrinkles uteruses Calvin lines and the r skin flabby after losing weight. The effect is long lasting.


【 De-fatting body slimming principle 】 The medical circulation rf system will produce columnar distributed hea in the subcutaneous tissue and fully make triglycerides release from the fat cells. Under the action of lipase the triglyceride will cracking into fatty acids and glycerin, then eliminated from the body along with the metabolism. Because of the intelligent system, the medical circulation rf instrument can orientate the fat cells, and release triglycerides quantificationally, thus achieved the localization, the effect of reducing weight rationally and quantificationally.


Vacuum Roller System


Click “BODY RF WITH VACUUM &ROLLER” enter the operation interface.

1. System default working time is 30 minutes, time range is 0:00~60:00 minutes, press one time to change one minute.

2. Power: RF 0 ~ 50 levels output to adjust.

3. Intensity: 10, 20, 30, 40, 60, 70, 80, 90, 100 Kpa for adjustment.

4. Mode: Vacuum rhythm frequency, total P1 ~ P6.


P0: Stop.

P1 suck 0.5s, release 0.5s; P2 suck 1.0s, release 1.0s;

P3 suck 2.0s, release 1.0s; P4 suck 3.0s, release 1.0s;

P5 suck 4.0s, release 1.0s; P6 suck 8.8s, release 8.8s;

Different modes can be selected according to the different parts.

5. When using the roller, press the power switch on the handle. The system defaults one-way rolling. To change the direction, we can adjust according to the below method:

One-way rolling:

①System defaults rolling forward together

②Press again, rolling in the opposite direction meanwhile.

Bothway rolling:

  • Two motor pieces rolls from outside to inside;
  • Press again, two motor pieces rolls from inside to outside.

6. Click “START”, instrument stars to work. Click “STOP”, the instrument stops working. Click to return (BACK), returns to the user interface.



Multipolar RF system ( Body Multi-Polar RF)

Click “BODY MULTI –POLAR RF” enter the operation interface.


1. System default working time is 30 minutes, time range is 0:00~60:00 minutes, press one time to change one minute.

2. The system default Intensity is 0. The intensity range is 0~33w /cm2, press one time to change 1 w /cm2.

3. The system default output of band is the third one (Continuous band), you can choose the band by click the band mode.

4. Click “START”, instrument stars to work. Click “STOP”, the instrument stops working. Click to return (BACK), returns to the user interface.


Tripolar RF system (Facial Tripolar RF)

Click “FACIAL TRI-POLAR RF” enter the operation interface.

1. System default working time is 30 minutes, time range is 0:00~60:00 minutes, press one time to change one minute.

2. The system default Intensity is 0. The intensity range is 0~33w /cm2, press one time to change 1 w /cm2.

3. The system default output of band is the third one (Continuous band), you can choose the band by click the band mode.

4. Click “START”, instrument stars to work. Click “STOP”, the instrument stops working. Click to return (BACK), returns to the user interface.



Cavitation and RF effect:

China Multifunction RF Beauty Machine Liposuction Slimming Machines With Touch Screen 60Hz RV9 supplier

Multifunction RF Beauty Machine Liposuction Slimming Machines With Touch Screen 60Hz RV9

Inquiry Cart 0