Helium Sniffer Testing Equipment for Air Conditioning Condenser Evaporator Piping 10E-6Pa.m3/s

Helium Sniffer Testing Equipment for Air Conditioning Condenser Evaporator Piping 10E-6Pa.m3/s

Brand Name:HongCe
Certification:CE,FCC,ROSH (Cost additional)
Model Number:HHLZ
Minimum Order Quantity:1 set
Delivery Time:3 months
Payment Terms:L/C, T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Guangdong China
Address: Room 202, Building 4-2, No. 539, Shibei Industrial Road, Dashi Street, Panyu District, Guangzhou, Guangdong
Supplier`s last login times: within 15 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Helium Sniffer Testing Equipment for Air Conditioning Condenser Evaporator Piping


According to the basic principles of helium leak detection, helium as a tracer gas, the workpiece will be filled with helium, and then through a helium leak detector leak can quickly and accurately determine the accuracy of the workpiece’s leakage.



Technical Parameters:


WorkpieceAir conditioning piping / coils
Tracer GasMixture helium & nitrogen (30% helium + 70% nitrogen) or pure helium
Leak Detection Rate2g/y, equal to 1x10-6Pa.m3/s
Leak detector setting accuracy1x10-8Pa.m3/s
Pressure for Gross Leak Detection4.0 Mpa (Downward adjustable)
Pressure for Fine Leak Detection4.0 Mpa (Downward adjustable)
Detection MethodManually held sniffer
Evacuation/ filling/ recovery joint2 stations (independent), 2 connectors per station (only 1/4 thread, customer-supplied connector)
Test Cycle

30s/pc

(Excluding loading / unloading workpiece and hand-held sniffer detection time)

Test Bench1500mm*600mm
high-pressure hose1.5m (4 pcs)
Platform height850MM
Equipment Composition

Operation platform + Helium filling & recovery system

(pipes for connecting the two parties are responsible for the customer)

Power SupplyThree-phase
AlarmThe system will alarm when the sniffer detects leakage signal
Leak Detection Description:
Operator places the workpiece on the jig on the test bench, seals the couplers of the workpiece with the jig manually;
After operator presses down “Start” button, high-pressure nitrogen is injected into the workpiece automatically until the pressure in the workpiece reaches the preset value;
System will stop nitrogen filling and automatically judge whether the workpiece has gross leakage according to the pressure drop value in the workpiece:
If the pressure drop value in the workpiece exceeds the preset range within a defined period, that indicates the workpiece has gross leakage. In that case, the gross leak detection process is stopped; and the gross leakage and “NG” instructions are shown on the operation interface; operator should click “Confirm” on the operation board to acknowledge the test results; the high-pressure nitrogen in the workpiece is automatically discharged until to a pressure of 1atm; workpiece is unloaded manually;
If the pressure drop value in the workpiece does not exceed the preset range within a defined period, that indicates the gross leak detection of the workpiece test is passed, next process is continued.
Workpiece is evacuated to the preset vacuum degree;
Preset high pressure helium is filled into workpiece;
Operator holds the sniffer to detect the helium around the workpiece;
Determine the fine leakage of workpiece automatically:

System will sum all the leakage rate of all the leakage points automatically, if the total helium weight detected exceeds the preset range, that indicates the workpiece has a fine leak. In that case, the fine leak detection process is stopped; and the fine leakage and “NG” instructions are shown on the operation interface; operator should click “Confirm” on the operation board to acknowledge the test results; next process is continued.

If the total helium weight detected does not exceed the preset range, that indicates the workpiece is qualified, and the OK signal is given on the operation interface; next process is continued.

Helium in workpiece will be recovered until the vacuum degree inside of workpiece reaches to preset value;
Air is charged to workpiece until to a pressure of 1atm;

Workpiece is unloaded by operator manually