Home /Mould Design & Processing Services /

SYS10 Integral Pilot Operated Solenoid Valve Armature Plunger Coil

SYS10 Integral Pilot Operated Solenoid Valve Armature Plunger Coil

Brand Name:Aeautel
Certification:CE,IOS9001
Model Number:SYS10
Minimum Order Quantity:1 piece
Delivery Time:1-7 work days
Payment Terms:T/T in advance,Western Union,Paypal,Credit card
Contact Now

Add to Cart

Verified Supplier
Location: Ningbo Zhejiang
Address: Liandong-U-Gu 17-2#, Shengyuan Road 1#, Jiangkou Street, Fenghua District, Ningbo City, Zhejiang Province, China
Supplier`s last login times: within 23 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Autel Pilot valve SYS10 Integral solenoid valve armature plunger coil


Description:
Used for Italy Autel pulse jet valves.
We use high quality material , the collection equipment efficiency can be improved , the energy loss also can be reduced.
The working frequency is stable
Its lifespan is about 1 million cycles.
Voltage: DC24V
Power: 17W

1 . The pulse diaphragm valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation.
2 . The high flow, angle type bodies in combination with the special main diaphragm assemblies give the unique operating features required for dust collector service applications
3 . The design with integral compression fittings will facilitate installation because there is no need for threaded piping
4 . The high quality diaphragms are reinforced and wear resistant to guarantee a long operating life, even under harsh conditions
5 . Integral pilot operated valves satisfy all relevant EC directives




Construction
BodyAluminum (Diecast)
WasherSS 304
ArmatureSS 430FR
Core and PlugnutStainless steel
Core SpringSS 304
Sealing & discNBR(nitrile/buna-n)
ScrewsSS302
DiaphragmPA-6(Standard), fluororubber
ConnectorPg9 IP65
Voltage230-150-24 V / 50-60 HZ AC
24 V DC
Working Temperature-20 to +85℃ Nitrile seals -29 to +232℃ fluororubber seals
Power Absorption17 VA AC / 17 W DC
Conn.Insulation classC-VDE 0110
Connector specificationDin 43650 – IS0 4400
Max Pressure8 Bar
Recommended on time range50-500ms
Recommended time between pulses1 minute or Less

General Description

In the high efficiency series we can include the range of flat surface valves. These valves, used for cleaning
filter elements in air filtration systems, are specifically designed for flat surfaces like square header tanks and
flanged tank. Like traditional model, with threaded and coupling connection, the activating can be:
Integrated the pilot is placed on the valve and the excitation (electric) is made by a coil.
Remote: the pilot is remote and the excitation is pneumatic. The connection between pilot and valve is made by
a simple pneumatic tube.
All That is achieved from a deep studying of internal geometrical characteristics and from a
technological research on diaphragm. This guarantees rapid opening-closing cycles and a working for
over a million of shots.


Introduction
Electromagnetic pulse valve refers to the gas through the valve in instantaneous once a electrical signal received. Just like pulse phenomena, it has the change of the short fluctuation. Therefore it is calls the pulse valve. The Industry standard definition of electromagnetic pulse valve for electromagnetic pilot valve and pulse valve together, diaphragm valve controlled by electrical signals.


Competitive Advantage:

Our product features:Our Services Guarantee:
1) Competitive price1) Prompt respond (Reply with 24 hours)
2) Good quality2) Free Samples (Customer pay for the delivery cost)
3) Professional Packaging,3) Registration support.
4) Produce according to Customers’ instruction4) Photos/videos are available during production.
5) None delay shipment

5) Loading inspection, and send loading photos before shipment.


Quality Standards :
The company for the products are brand new original products, no second-hand and refurbished products, or leave a compensable ten and return the full amount , but the buyer due to our purchase of model error is not responsible for returns, another of the company's sales of products enjoy one year from the date of shipment quality assurance , according to the original quality standards , during warranty with product problems , need confirmation testing by the manufacturer , the supplier to be solved , the demand side due to storage , use, poor maintenance caused by lower-quality product , and not raise objections

Warranty:
All item Comes with Basic 3 Month Sellers Warranty, if item defective in 3 Month, We will offer replacement without extra Charger(including shipping fee)After we Receive the Defective item.
If item Defective after 3 Month, Buyers can still send it back, We will contact suppliers or Manufactory for Warranty. Buyers Might Need to pay the Shipping fee For resend the replaced item.

Introduction
Electromagnetic pulse valve refers to the gas through the valve in instantaneous once a electrical signal received. Just like pulse phenomena, it has the change of the short fluctuation. Therefore it is calls the pulse valve. The Industry standard definition of electromagnetic pulse valve for electromagnetic pilot valve and pulse valve together, diaphragm valve controlled by electrical signals.

Working principle
Electrical pulse controller send input signals so that the electromagnetic armature attracts the moving bar. Unclose the balancing hole to release the pressure gas in the back cavity of diaphragm quickly; the pressure gas in the front cavity holds up the diaphragm to open the passage and the valve starts cleaning.
The pulse signal disappears and the spring of the armature works immediately to resume the moving bar so as to close the balancing hole. The pressure gas in the back cavity of the diaphragm and the spring work together to close the passage the valve stops cleaning.
The damping hole in the diaphragm functions to damp the airflow when the moving bar of armature holds up for balancing and to transit the air to the back cavity as soon as the balancing hole is shut to close the passage and stop cleaning.

The installment introduction:
1. First, Confirm the pulse valve in good condition and then installed
2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.

China SYS10 Integral Pilot Operated Solenoid Valve Armature Plunger Coil supplier

SYS10 Integral Pilot Operated Solenoid Valve Armature Plunger Coil

Inquiry Cart 0