R409a refrigerant (mixed refrigerant) retrofit for R-12 and R-500 stationary DX systems

R409a refrigerant (mixed refrigerant) retrofit for R-12 and R-500 stationary DX systems

Brand Name:STARGET, Neutral
Certification:SGS/ROSH/PONY/ISO9001/ISO14001/ISO1694
Minimum Order Quantity:1 cylinder
Delivery Time:10-20 days
Payment Terms:T/T,L/C,D/P
Packaging Details:Non-refillable cylinder-11.3kg(30lbs) Refillable cylinder-400L,800L,1000L
Contact Now

Add to Cart

Active Member
Location: Beijing Beijing China
Address: No. 2, South Jinzhan Road, Jinzhan Xiang, Chaoyang District , Beijing China (Mainland)
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

R409a refrigerant (mixed refrigerant) retrofit for R-12 and R-500 stationary DX systems


An interim replacement for CFC-12 in refrigeration systems. Low- and medium-temperature retrofits.


Retrofit:R-409A is the recommended retrofit for R-12 and R-500 stationary DX systems, where an oil change to POE is not practical. R-409A is not recommended for use in automotive air conditioning system, or systems that utilize a flooded evaporator (i.e. centrifugal chillers). For these systems, R-134a is the recommended retrofit product.
Retrofitting Procedures
1. Establish baseline performance. Note the oil type in use and any system operating data (if system is operating properly). Check for existing leaks and identify any needed repairs.
2. Recover the existing refrigerant charge (DO NOT vent to atmosphere). Weigh the amount of refrigerant removed.
3. Perform any repairs identified in step 1 and fix any leaks.
4. Replace the filter-drier, and if necessary, elastomeric seals (O-rings. sight glasses. etc.). Verify the condition of the system oil; replace if necessary.
5. Oil changes are typically not required for R-409A. For low temperature mineral oil based systems, a partial (greater than 30%) oil change to AB is recommended.
6. Evacuate the system (less than 500 microns) and ensure it maintains a vacuum. If vacuum is lost, it may indicate that leaks are present in the system.
7. Charge system with R-409A refrigerant. Remove refrigerant as liquid only from cylinder. The initial charge amount should be approximately 85 – 90% of the standard charge for R-12 for TXV systems, and 80% for cap tube systems.
8. Adjust TXV set point and/or refrigerant charge to achieve the desired superheat. Low side pressure control settings may also need to be adjusted.
9. Monitor oil levels in the compressor. If necessary, adjust oil amounts to attain normal operating level (mid sight glass).
10. Label system clearly, indicating the type and amounts of system refrigerant and oil.


Specifications:

Property of chloride :

Molecular Weight

97.4

Boiling Point, °C

-34.5

Critical Temperature, °C

106.8

Critical Pressure, Mpa

4.69

Saturated Liquid Density, 25°C, (g/cm3)

1.216

Specific Heat of Liquid, 30°C, [KJ/(kg°C)]

0.29

ODP

0.039

GWP

0.15


Quality standard :

Purity, %

≥99.8

Moisture, PPm

≤10

Acidity, PPm

≤1

Vapor Residue, PPm

≤100

Appearance

Colorless, Clear

Odor

Odorless



Applications:Applications include many medium temperature refrigeration systems, vending machines, refrigerators, positive displacement chillers, humidifiers, and other systems using R-12 or R-500.


Competitive Advantage:

1.R409a of all specifications
2.OEM is accepted
3.Purity 99.8%
4.Certifications of
SGS/ROSH/PONY/ISO9001/ISO14001/ISO16949

China R409a refrigerant (mixed refrigerant) retrofit for R-12 and R-500 stationary DX systems supplier

R409a refrigerant (mixed refrigerant) retrofit for R-12 and R-500 stationary DX systems