New Technology Cryolipolysis / Cryotherapy slimming machine with
Cooling handle
1. Honorable Clients
Thanks for your attention to our products S042 Cryolipolysis
System.
For better use this machine, please read through the user manual
and follow the isntruction of this machine in detail when you
operate the machine.
It forbids someone to open and remove the mainframe of this machine
besides authorized from the our company.
Please contanct our in time if there are any question during
operation.
Professional technique from our company to satisfy your kinds of
requirements in a good way.
2. Technical background
Excessive body fat can damage people's appearance and athletic
ability, may also cause various diseases. Excessive adipose tissue
may be located in various parts of the body, such as: thighs,
buttocks, abdomen, knee, back, face, arms and other areas. And
excessive fatty tissue will form a honeycomb of ugly appearance.
Excessive body fat may be associated with health risks, and
therefore the need for effective control or elimination of excess
fat approach.
To diminish the stubborn body fat, in addition to the use of RF
heating, laser-assisted liposuction and high-intensity focused
ultrasound to speed up their metabolism, you can try using fresh
Cryolipolysis technology to thin layer of fat, thereby achieving
self-cultivation and plastic shaped effect.
The latest Cryolipolysis technology is opposite to the way of
heating which than other non-invasive means of new and more
effective methods. A revolutionary new concept of fat soluble, It
has proved it is major breakthrough technology for body reshaping,
dissolving fat when it has been put to use.
For which a reasonable diet, regular exercise but still throw off
the fat of the local people, the latest technology Crylipolysis
technology condensate is a godsend. Whether it is a relatively
dense area of fat, or fat, smaller parts, such as: hips above the
waist on both sides of relaxation of the fat, belly and back fat,
the fat soluble refrigeration technology can produce stunning
results.
Blue Light has a relaxing effect, all heat-related illnesses and
need to Blue treatment, conditioning the muscles, ligaments and
tissue contraction, quiet and modest results.
3.Cryolipolysis Theory
Throughing the freezing effect, remove the fat cell triglyceride
off heat, and will remain at 4 ℃, so the cold coagulation, and
therefore premature aging and death. Fat cells in the cold, it will
start clearing the natural decomposition process, so that gradually
thinner fat layer. Through the normal metabolic processes,
decreasing the fat layer, to achieve the purpose of partial melting
fat.
Fat cells can be significantly reduced, the fat layer also will
become thinner, so that the fat blocks will be killed one by
one.Cooling Skin protection while lifting and tightening.The
contact cooling of the handpiece surface regulates the temperature
of the skin and protects fine dermal structures, realizing the fast
body-reshape effects while tightening skin!
4. Operate Instructon
5. Treatment Setting
1. One part of a working time between 30 to 50 minutes (depending
on the capacity of the human body set).
2. For the cellulite removal for the parts of body, each time just
can only be for a cellulite removal for one part, regarding the
Cellulite of waist, if you want celluite removal for the whole
waist, it need to receive multiple treatments to complete items for
what your want.
3. Within 2 or 3 months, the same position after accepted the first
course treatment to undergo another course of frozen fat soluble,
it can reduce the extra fat layer thickness, Continue twice
received treatment to dissolve fat plus freezing effect, but
continued to repeat the accepted treatment at random is not
recommended .
4.The cryolipolysis treatment designed for localized hypertrophic
fat accumulation area, physical healthy
people, but not suitable for Overall obesity. treatment mainly for
a particular part, such as waist fat, belly
and back, and other local cellulite. Treatment is not omnipotent
and can not cure obesity, it can not
replace liposuction or other invasive therapies. A Substantial
weight loss should be through a balanced
diet and do regular exercise, cryolipolysis treatment can only be
carried out for extra fat.
6. Skin Antifreeze
Qualified antifreeze should be used during the treatment, to avoid
frostbite when temerature lower to the
0 to -40 degree. [Consumables, purchase on your own]
7. Operation Process
1.Check the thickness of the fat
2.Clean treatment area , Clear the hair of the treatment area
3.Mark the size of treatment area
4.Use antifreeze on the treatment area
5.Paste antifreeze membrane at treatment part.
6. Patients receiving the treatment should be sitting Make upper
body and lower limbs to 90 degrees.
7. According to the patient endurance of fat thickness and size
selection suction.
8. The refrigeration device gently dissolve fat absorption
treatment site, press the” START” button.
9. Starts suction instrument itself will remain unchanged.
10.25-30 minutes after treatment, press the control button in the
handle, to stop the suction.And check and add antifreeze.
11.Repeat steps 7 to 10 until the treatment course finished[press
the start button the again] and turn off the power.
8. Operation Cautions
1.The equipment must be operated by professionals
2.Do not use without antifreeze
3.The equipment must be used by professionals
4.Patients using the following medical electrical equipment can not
use the equipment.
Implanted cardiac pacemakers or other implanted electronic devices;
life-sustaining artificial heart-lung machines and other equipment;
Portable ECG measurement equipment;
5.The following patients should be agreed by the professional
doctors before using the equipment.
patients with acute disease;
Malignancy
patients with Infectious diseases
pregnant women;
patients with heart diseases
patients with fever
patients are receiving treatment or those with abnormal body
phenomenon;
7.The following patients using this device should be taken care of.
infants and young children;
Sensory or physically impaired persons;
9. Contraindications
Liver problems, the Raynaud's disease, severe cold urticaria,
cryoglobulinemia, cold fiber hypoproteinemia, severe frostbite, a
serious disease of sugar and the quiet old age, young children,
frail and so on frozen not tolerate the treatment.
Environmental protection and safety precautions
To abandon or disassemble the equipment should under the guidance
of the local law, sent to specialized
agencies.
Names and contents of Toxic and hazardous substances or elements
Remarks said that the content of hazardous substance in all
materials in the parts below the standard of SJ/T11363-2006 limit
requirement.indicates that the content of toxic or hazardous
substance in at least one of the homogeneous materials for this
part exceeding the SJ/T11363-2006 limit requirement.1363-2006.
Technical Note
Hardware structure of the machine parts, injection molded parts,
and the majority of electronic components, connectors meet the
requirements of the EU and China RoHS directives, Only a few parts
as the global technology limitations that may affect product
reliability and not find a substitute for the toxic and hazardous
substances, please be assured to use, use under normal conditions
will not cause health effects on users.
Maintenance Instruction
1.Medical equipment or appliances close to the device may be
resulting in operational failure due to
interference,
2.The machine is a precise apparatus, do not use it at place with
high temperature, humidity, dusty, smokes,
and vapor.
3.If there comes a failure, please shut down the power immediately,
and send it to the distributor or
manufacturer for maintenance. Do not repair on your own.
4.The cooling fluid is pure water, keep it clean during
transportation or long time no use. And should be
canned properly before use.
5.Exclusion of liability
(1)If fire, earthquake, war occurred.
(2)The fault of the user, operator error;
(3)Damage caused by using other method(not included in the use
manual).
(4)Operate without the manual's guide.
Parameter
1.Machine Measure:112CMX52CMX51CMCM(160CM WITH SHELF)
2.Outside Package:126CMX60CMX58CM
3.Light wavelength: 492~455nm
4.Voltage:220V/50Hz or 110V/50Hz or 110V/60Hz;
5.Touch Screen:8 inch colour touch screen;
6.Power Consumption: ≤400W;
7. Cooling device output temperature:5 degree~-5℃ degree
8.Cooling device output pressure :0-100Kpa
9.Cooling liquid: pure water
10.Default working time:0-60 minutes
11.Fuse size:F3AL250V
12.Net Weight:30KGS, Gross Weight:45KGS
13.Relative Humidity: 85%
14. Atmospheric pressure:88KPa ~110KPa
Accessories List
1.Power supply line 1pc
2.Handle support 1set
3. Handle Support screw: 1pc
4.Cooling liquid tank 1set
5.Cooling handle 1set
6. Screwdriver 1pc
7. User Manual 1copy