Home /Other Batteries /

Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen

Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen

Brand Name:TAC OEM ODM
Certification:MSDS REACH ROHS
Model Number:PIFC0030
Minimum Order Quantity:200PCS
Delivery Time:7 days for single cell 15-20 days for battery pack
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: No.27 BOWANG Street ,Nan Cun Town, Panyu, Guangzhou, GD,China
Supplier`s last login times: within 30 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen

Other name : RCR2 Rechargeable CR2

Feature for Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen


1. The model name:IFR15270/RCR2 3.2V 200mAh
2. 3.2V IFR15270/CR2 200mAh LiFePO4 battery can replace 3.0V CR2 non-rechargeable Lithium battery
3. There is a long cycle life,it is about 2000 times
4. The application is widely,for digital camera,ACP pen and so on.
5. High energy density,High open circuit voltage
6. Wide range of operating temperature,Stable operating voltage and current
7. Low self-discharge rate (less than 2% per year at 20°C).


Specification for Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen


No.

Item

General Parameter

Remark

1

Rated Capacity

Typical

200mAh

Standard discharge(0.2 C5A) after Standard charge

Minimum

190mAh

2

Nominal Voltage

3.2V

Mean Operation Voltage

3

Voltage at end of
Discharge

2.0V

Discharge Cut-off Voltage

4

Charging Voltage

3.65V


5

Internal Impedance

≤150mΩ

Internal resistance measured at AC 1KHZ after 50% charge
The measure must uses the new batteries that within one week after shipment and cycles less than 5 times

6

Standard charge

Constant Current 0.2C5A
Constant Voltage 3.65V
0.01 C5A cut-off


7

Standard discharge

Constant current 0.2 C5A
end voltage 2.0V



Test Standard for Charge And Discharge


8

Fast charge

Constant Current 1C5A
Constant Voltage 3.65V
0.01 C5A cut-off


9

Fast discharge

Constant current 1 C5A
end voltage 2.0V


10

Maximum Continuous Charge Current

1 C5A


11

Maximum Continuous Discharge Current

1.5C5A


12

Operation Temperature Range

Charge: 0~45℃

60±25%R.H.
Bare Cell

Discharge: -10~60℃

13

Storage Temperature Range

Less than 1 year: -20~25℃

60±25%R.H.
at the shipment state

less than 3 months: -20~40℃

Less than 7 day : -20~65℃

14

Cell Dimension

High: 27.0±0.5 mm

Initial Dimension

Diameter:15.0±0.5 mm

Main Applications :


1. Utility meter (water, electricity, gas meter, AMR)
2. Alarm or security equipment (smoke alarm system, detector)
3. GPS tracking
4. Teal time clock
5. Digital control machine
6. Military
7. Remote monitoring systems
8. Car electronics
9. Camera

10. 3v Lithium Battery Rechargeable CR2 cell With Charger for Meridian Pen



Drawing for Cell


Photo for Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen


Normal Packing for Cell

50pcs in one inner box and then 8 box in one export carton




Available Model for the LIFePO4 Button Cell:


MODELCAPACITYVOLTAGE
IFR1012035mah3.2V
IFR10440200mah3.2V
IFR14430300mah3.2V
IFR14430400mah3.2V
IFR14430450mah3.2V
IFR14430 FLAT450mah3.2V
IFR14430500mah3.2V
IFR14505250mah3.2V
IFR14505300mah3.2V
IFR14505400mah3.2V
IFR14500 FLAT600mah3.2V
IFR14505600mah3.2V
IFR15270200mah3.2V
IFR17335450mah3.2V
IFR18500600mah3.2V
IFR18500800mah3.2V
IFR185001000mah3.2V
IFR186501000mah3.2V
IFR18650P1100mah3.2V
IFR186501200mah3.2V
IFR186501500mah3.2V
IFR266503000mah3.2V
IFR266503300mah3.2V


Cautions in use
To ensure proper use of the battery please read the manual carefully before using it.
. Handling

  • Do not expose to, dispose of the battery in fire.
  • Do not put the battery in a charger or equipment with wrong terminals connected.
  • Avoid shorting the battery
  • Avoid excessive physical shock or vibration.
  • Do not disassemble or deform the battery.
  • Do not immerse in water.
  • Do not use the battery mixed with other different make, type, or model batteries.
  • Keep out of the reach of children.

. Storage

  • Store the battery in a cool, dry and well-ventilated area.

. Disposal

  • Regulations vary for different countries.
  • Dispose of in accordance with local regulations.


Battery operation instruction

Discharging current

The discharging current does not have to surpass this specification book stipulation the biggest discharging current, the over sized electric current electric discharge can cause the battery capacity play to reduce and to cause the battery heat.


Electric discharge temperature

The battery discharge must carry on in the ambient temperature scope which this specification book stipulated.


Storing the Batteries

The battery should store in the product specification book stipulation temperature range. If has surpasses above for six months the long time storage, the discharge capacity will decrease sharply.

Period of Warranty
Because batteries utilize a chemical reaction, battery performance will deteriorate over time even if stored for a long period of time without being used. In addition, if the various usage conditions such as discharge, ambient temperature, are not maintained within the specified ranges the life expectancy of the battery may be shortened or the device in which the battery is used may be damaged by electrolyte leakage. Please change the battery in time.

Lifepo4 Battery Production List


China Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen supplier

Rechargeable 3.0V CR2 LiFePO4 Battery for Medical Equipment Massage Pen

Inquiry Cart 0