Taikang building 2605, southern business zone, Yinzhou district, Ningbo, Zhejiang, China 315199
YT102 2-wire Smoke Detector
Products Addressable Fire Alarm System Convenient Fire Alarm System Stand-alone Fire Alarm Gas Extinguishing Systems Contact Us Tel: +86 755 2981 0450 Fax: +86 755 2370 7411 Mobile: +86 139 2340 6919 Email: sales@atlfire.hk Position: Home > Products > Gas Extinguishing Systems > Product details Product details YT102 2-wire Smoke Detector The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is...
Addressable fire alarm systems 2 wire smoke detector sensor
Addressable fire alarm systems 2 wire smoke detector sensor SPECIFICATIONS: Operating Voltage Range: 15 to 28 VDC Standby Current: 400µA @ 24 VDC (one communication every 5 seconds with LED blink enabled) Maximum Alarm Current (LED on: ) 7 mA @ 24 VDC Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing Operating Temperature Range: 14°F to 122°F (-10°C to50°C) Smoke Sensitivity: 1.06±.26%FT. Height: 2.2˝ (55 mm) installed in...
Shenzhen KINGUI Limited
Address:3/F, 6Bldg, Guilin Industry Area,Baoan district,Shenzhen, China.
4 Wire smoke detector with signal output
Smoke Detector With Network Signal Output Products Feature: The detector works once connected to DC power directly. Operation indicator flashing signifies detectors working normally and alarming indicator on signifies detector alarming. Built-in a couple of outpot contact, which keep close when work normally and disconect after alarm. Auto-reset when no smoke existing nearby, installing with mounting base. . INFRARED PHOTOELECTRONICS SENSOR ....
Yiwu Yidun E-commerce Firm
2-3/f, B Building Hua Feng No 1 Industrial Park, Gu Shu baoan,china.
Addressable fire alarm systems 2 wire smoke detector sensor
Addressable fire alarm 24V 2 wire systems smoke detector sensor Specification: Working voltage: DC24V ± 20% Working current: monitoring status <50uA, alarm status: 20mA Work instructions: monitoring status indicator flashes red once per 6 seconds, alarm status indicator light is lit. Weight: about 100g Dimensions:100mmx55mm Connection: non-polarity two wire Use of the environment: indoor, temperature -10 ℃ ~ 55 ℃, relative humidity ≤95% (40 ℃ ± 2...
Jingo International CO., LTD
3/F, 8Bldg, guilin Industry Area,Baoan district,Shenzhen, China.
2 Wire Smoke Detector
Products Feature: The detector works once connected to DC power directly. Operation indicator flashing signifies detectors working normally and alarming indicator on signifies detector alarming. Built-in a couple of outpot contact, which keep close when work normally and disconect after alarm. Auto-reset when no smoke existing nearby, installing with mounting base. . INFRARED PHOTOELECTRONICS SENSOR . AUTO RESET . INTELLIGENT LOGIC CONTROL ....
Yiwu Yidun E-commerce Firm
2-3/f, B Building Hua Feng No 1 Industrial Park, Gu Shu baoan,china.
4 Wire Smoke Detector
Products Feature: The detector works once connected to DC power directly. Operation indicator flashing signifies detectors working normally and alarming indicator on signifies detector alarming. Built-in a couple of outpot contact, which keep close when work normally and disconect after alarm. Auto-reset when no smoke existing nearby, installing with mounting base. . INFRARED PHOTOELECTRONICS SENSOR . AUTO RESET . INTELLIGENT LOGIC CONTROL ....
Yiwu Yidun E-commerce Firm
2-3/f, B Building Hua Feng No 1 Industrial Park, Gu Shu baoan,china.
YT142 4-Wire Smoke Detector with Relay Output
Product Overview The detectors are photo-electronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most security alarm control panel. Two LEDs on each detector provide local 360° visible alarm indication. They flash every six seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. The detector can be reset...
Product overview The device is photoelectronic detector uses a state of-the-art optical sensing chamber. This detector is designed to provide open area protection and to be used with most conventional fire alarm control panel. Two LEDs on each detector provide local 360°visible alarm indication. They flash every 3~5 seconds indicating that power is applied and the detector is working properly. The LEDs latch on in alarm. LEDs will be off when a...